메뉴 건너뛰기




Volumn 59, Issue 4, 2010, Pages 525-530

Efficacy of bougie in difficult intubation with the Airway Scope® caused by inability to lift the epiglottis directly

Author keywords

Airway Scope ; Bougie; Difficult intubation with the Airway Scope

Indexed keywords

ARTICLE; BOUGIE; CLINICAL ARTICLE; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; EPIGLOTTIS; GENERAL ANESTHESIA; GLOTTIS; HUMAN; MUSCLE RELAXATION;

EID: 77951568867     PISSN: 00214892     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (19)
  • 2
    • 41949120312 scopus 로고    scopus 로고
    • Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: A randomized comparative study
    • DOI 10.1093/bja/aen002
    • Enomoto Y, Asai T, Arai T, Kamishima K, Okuda Y. Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study. Br J Anaesth 2008; 100: 544-548 (Pubitemid 351773605)
    • (2008) British Journal of Anaesthesia , vol.100 , Issue.4 , pp. 544-548
    • Enomoto, Y.1    Asai, T.2    Arai, T.3    Kamishima, K.4    Okuda, Y.5
  • 3
    • 43549107680 scopus 로고    scopus 로고
    • The Pentax-AWS® rigid indirect video laryngoscope: Clinical assessment of performance in 320 cases
    • DOI 10.1111/j.1365-2044.2008.05452.x
    • Suzuki A, Toyama Y, Katsumi N, Sasaki R, Hirota K, Iwasaki H, et al. The Pentax-AWS® rigid indirect video laryngoscope: clinical assessment of performance in 320 cases. Anaesthesia 2008; 63: 641-647 (Pubitemid 351677330)
    • (2008) Anaesthesia , vol.63 , Issue.6 , pp. 641-647
    • Suzuki, A.1    Toyama, Y.2    Katsumi, N.3    Kunisawa, T.4    Sasaki, R.5    Hirota, K.6    Henderson, J.J.7    Iwasaki, H.8
  • 5
    • 60049095026 scopus 로고    scopus 로고
    • Combination of Airway Scope and bougie for a full-stomach patient with difficult intubation caused by unanticipated anatomical factors and cricoid pressure
    • Takenaka I, Aoyama K, Kinoshita Y, Iwagaki T, Takenaka Y, Kadoya T, et al. Combination of Airway Scope and bougie for a full-stomach patient with difficult intubation caused by unanticipated anatomical factors and cricoid pressure. J Clin Anesth 2009; 21: 64-66
    • (2009) J Clin Anesth , vol.21 , pp. 64-66
    • Takenaka, I.1    Aoyama, K.2    Kinoshita, Y.3    Iwagaki, T.4    Takenaka, Y.5    Kadoya, T.6
  • 6
    • 77951612152 scopus 로고    scopus 로고
    • Japanese source
  • 8
    • 0036205630 scopus 로고    scopus 로고
    • Survey of the use of the gum elastic bougie in clinical practice
    • DOI 10.1046/j.1365-2044.2002.02411.x
    • Latto IP, Stacey M, Mecklenburgh J, Vaughan RS. Survey of the use of the gum elastic bougie in clinical practice. Anaesthesia 2002; 57: 379-384 (Pubitemid 34279462)
    • (2002) Anaesthesia , vol.57 , Issue.4 , pp. 379-384
    • Latto, I.P.1    Stacey, M.2    Mecklenburgh, J.3    Vaughan, R.S.4
  • 9
    • 3242884152 scopus 로고    scopus 로고
    • Difficult airway society guidelines for management of the unanticipated difficult intubation
    • Henderson JJ, Popat MT, Latto IP, Pearce AC. Difficult airway society guidelines for management of the unanticipated difficult intubation. Anaesthesia 2004; 59: 675-694
    • (2004) Anaesthesia , vol.59 , pp. 675-694
    • Henderson, J.J.1    Popat, M.T.2    Latto, I.P.3    Pearce, A.C.4
  • 10
    • 0021701206 scopus 로고
    • Difficult tracheal intubation in obstetrics
    • Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-11.
    • (1984) Anaesthesia , vol.39 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 12
    • 33846207382 scopus 로고    scopus 로고
    • Airway Scope for difficult intubation
    • Asai T, Enomoto Y, Okuda Y. Airway Scope for difficult intubation. Anaesthesia 2007; 62: 199.
    • (2007) Anaesthesia , vol.62 , pp. 199
    • Asai, T.1    Enomoto, Y.2    Okuda, Y.3
  • 14
    • 0028104556 scopus 로고
    • Evaluation of the Bullard laryngoscope using the new intubating stylet: Comparison with conventional laryngoscopy
    • Cooper SD, Benumof JL, Ozaki GT. Evaluation of the Bullard laryngoscope using the new intubating stylet: comparison with conventional laryngoscopy. Anesth Analg 1994; 79: 965-970
    • (1994) Anesth Analg , vol.79 , pp. 965-970
    • Cooper, S.D.1    Benumof, J.L.2    Ozaki, G.T.3
  • 15
    • 34548602041 scopus 로고    scopus 로고
    • Cervical spine movement during laryngoscopy using the airway scope compared with the macintosh laryngoscope
    • DOI 10.1111/j.1365-2044.2007.05188.x
    • Hirabayashi Y, Fujita A, Seo N, Sugimoto H. Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope. Anaesthesia 2007; 62: 1050-1055 (Pubitemid 47399399)
    • (2007) Anaesthesia , vol.62 , Issue.10 , pp. 1050-1055
    • Hirabayashi, Y.1    Fujita, A.2    Seo, N.3    Sugimoto, H.4
  • 16
    • 38449091187 scopus 로고    scopus 로고
    • Upper cervical spine movement during intubation: Fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope
    • DOI 10.1093/bja/aem313
    • Maruyama K, Yamada T, Kawakami R, Kamata T, Yokochi M, Hara K. Upper cervical spine movement during intubation: fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope. Br J Anaesth 2008; 100: 120-124 (Pubitemid 351773415)
    • (2008) British Journal of Anaesthesia , vol.100 , Issue.1 , pp. 120-124
    • Maruyama, K.1    Yamada, T.2    Kawakami, R.3    Kamata, T.4    Yokochi, M.5    Hara, K.6
  • 17
    • 2942659508 scopus 로고    scopus 로고
    • Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: Incidence, causes and solutions
    • DOI 10.1093/bja/aeh136
    • Asai T, Shingu K. Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes, and solutions. Br J Anaesth 2004; 92: 870-881 (Pubitemid 38771691)
    • (2004) British Journal of Anaesthesia , vol.92 , Issue.6 , pp. 870-881
    • Asai, T.1    Shingu, K.2
  • 18
    • 77951561719 scopus 로고    scopus 로고
    • Japanese source
  • 19
    • 0037317687 scopus 로고    scopus 로고
    • The Parker flex-tip tube versus a standard tube for fiberoptic orotracheal intubation. A randomized double-blind study
    • Kristensen MS. The Parker flex-tip tube versus a standard tube for fiberoptic orotracheal intubation. A randomized double-blind study. Anesthesiology 2003; 98: 354-358
    • (2003) Anesthesiology , vol.98 , pp. 354-358
    • Kristensen, M.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.