메뉴 건너뛰기




Volumn 178, Issue 1-3, 2010, Pages 157-163

Preparation of a new chromium(III) selective electrode based on 1-[(2-hydroxy ethyl) amino]-4-methyl-9H-thioxanthen-9-one as a neutral carrier

Author keywords

1 (2 hydroxy ethyl) amino 4 methyl 9H thioxanthen 9 one; Carbon paste electrode; Chromium selective electrode; Potentiometric sensor

Indexed keywords

1-[(2-HYDROXY ETHYL) AMINO]-4-METHYL-9H-THIOXANTHEN-9-ONE; A-CARBON; CARBON PASTE ELECTRODE; CARBON PASTES; DETECTION LIMITS; ELECTRODE RESPONSE; FIXED INTERFERENCE METHOD; GRAPHITE POWDER; INTERFERING IONS; ION CONCENTRATIONS; MASS RATIO; NEUTRAL CARRIER; OPTIMUM VALUE; PERFORMANCE CHARACTERISTICS; POTENTIAL METHODS; RESPONSE TIME; SELECTIVE ELECTRODES; SELECTIVITY COEFFICIENT; SODIUM TETRAPHENYLBORATE; SOLUTION METHODS;

EID: 77951498984     PISSN: 03043894     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhazmat.2010.01.057     Document Type: Article
Times cited : (63)

References (34)
  • 1
    • 0001255774 scopus 로고
    • Determination of chromium(III) and chromium(VI) in water using flow injection on-line preconcentration with selective adsorption on activated alumina and flame atomic absorption spectrometric detection
    • Sperling M., Xu S., Welz B. Determination of chromium(III) and chromium(VI) in water using flow injection on-line preconcentration with selective adsorption on activated alumina and flame atomic absorption spectrometric detection. Anal. Chem. 1992, 64:3101-3108.
    • (1992) Anal. Chem. , vol.64 , pp. 3101-3108
    • Sperling, M.1    Xu, S.2    Welz, B.3
  • 2
    • 67449147321 scopus 로고    scopus 로고
    • Highly selective perchlorate membrane electrode based on cobalt(III) schiff base as a neutral carrier
    • Shokrollahi A., Ghaedi M., Rajabi H.R., Kianfar A.H. Highly selective perchlorate membrane electrode based on cobalt(III) schiff base as a neutral carrier. Chin. J. Chem. 2009, 27:258-266.
    • (2009) Chin. J. Chem. , vol.27 , pp. 258-266
    • Shokrollahi, A.1    Ghaedi, M.2    Rajabi, H.R.3    Kianfar, A.H.4
  • 3
    • 52949141473 scopus 로고    scopus 로고
    • Thiocyanate-selective membrane electrode based on cobalt(III) Schiff base as a charge carrier
    • Shokrollahi A., Ghaedi M., Ghaedi H., Kianfar A.H. Thiocyanate-selective membrane electrode based on cobalt(III) Schiff base as a charge carrier. Int. J. Environ. Anal. Chem. 2008, 88:841-856.
    • (2008) Int. J. Environ. Anal. Chem. , vol.88 , pp. 841-856
    • Shokrollahi, A.1    Ghaedi, M.2    Ghaedi, H.3    Kianfar, A.H.4
  • 4
    • 57649216265 scopus 로고    scopus 로고
    • Preconcentration and separation of trace amount of heavy metal ions on bis(2-hydroxy acetophenone) ethylendiimine loaded on activated carbon
    • Ghaedi M., Shokrollahi A., Kianfar A.H., Pourfarokhi A., Khanjari N., Mirsadeghi A.S., Soylak M. Preconcentration and separation of trace amount of heavy metal ions on bis(2-hydroxy acetophenone) ethylendiimine loaded on activated carbon. J. Hazard. Mater. 2009, 162:1408-1414.
    • (2009) J. Hazard. Mater. , vol.162 , pp. 1408-1414
    • Ghaedi, M.1    Shokrollahi, A.2    Kianfar, A.H.3    Pourfarokhi, A.4    Khanjari, N.5    Mirsadeghi, A.S.6    Soylak, M.7
  • 5
    • 34250157356 scopus 로고    scopus 로고
    • Construction of suitable iodide-selective electrode based on phenyl mercury (II)(2-mercaptobezothiozolate) carrier
    • Shokrollahi A., Ghaedi M., Montazerozohori M., Hosaini O., Ghaedi H. Construction of suitable iodide-selective electrode based on phenyl mercury (II)(2-mercaptobezothiozolate) carrier. Anal. Lett. 2007, 40:1714-1735.
    • (2007) Anal. Lett. , vol.40 , pp. 1714-1735
    • Shokrollahi, A.1    Ghaedi, M.2    Montazerozohori, M.3    Hosaini, O.4    Ghaedi, H.5
  • 6
    • 0032099044 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    • Buhlmann P., Pretsch E., Bakker E. Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors. Chem. Rev. 1998, 98:1593-1687.
    • (1998) Chem. Rev. , vol.98 , pp. 1593-1687
    • Buhlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 7
    • 0035951531 scopus 로고    scopus 로고
    • Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene
    • Abbaspour A., Izadyar A. Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene. Talanta 2001, 53:1009-1013.
    • (2001) Talanta , vol.53 , pp. 1009-1013
    • Abbaspour, A.1    Izadyar, A.2
  • 8
    • 0030353029 scopus 로고    scopus 로고
    • Hydrogen chromate PVC matrix membrane sensor for potentiometric determination of chromium(III) and chromium(VI) ions
    • Saad S.M., Hassan M.N., Abbas G.A.E., Moustafa Hydrogen chromate PVC matrix membrane sensor for potentiometric determination of chromium(III) and chromium(VI) ions. Talanta 1996, 43:797-804.
    • (1996) Talanta , vol.43 , pp. 797-804
    • Saad, S.M.1    Hassan, M.N.2    Abbas, G.A.E.3    Moustafa4
  • 9
    • 0037773252 scopus 로고    scopus 로고
    • Chromium(III) ion selective electrode based on glyoxal bis(2-hydroxyanil)
    • Gholivand M.B., Sharifpour F. Chromium(III) ion selective electrode based on glyoxal bis(2-hydroxyanil). Talanta 2003, 60:707-713.
    • (2003) Talanta , vol.60 , pp. 707-713
    • Gholivand, M.B.1    Sharifpour, F.2
  • 10
    • 33646544349 scopus 로고    scopus 로고
    • Highly selective and sensitive chromium(III) membrane sensors based on a new tridentate Schiff's base
    • Ganjali M.R., Norouzi P., Faridbod F., Ghorbani M., Adib M. Highly selective and sensitive chromium(III) membrane sensors based on a new tridentate Schiff's base. Anal. Chim. Acta 2006, 569:35-41.
    • (2006) Anal. Chim. Acta , vol.569 , pp. 35-41
    • Ganjali, M.R.1    Norouzi, P.2    Faridbod, F.3    Ghorbani, M.4    Adib, M.5
  • 11
    • 33748289509 scopus 로고    scopus 로고
    • Highly selective and sensitive chromium(III) membrane sensors based on 4-amino-3-hydrazino-6-methyl-1,2,4-triazin-5-one as a new neutral ionophore
    • Zamani H.A., Rajabzadeh Gh., Ganjali M.R. Highly selective and sensitive chromium(III) membrane sensors based on 4-amino-3-hydrazino-6-methyl-1,2,4-triazin-5-one as a new neutral ionophore. Sens. Actuators B 2006, 119:41-46.
    • (2006) Sens. Actuators B , vol.119 , pp. 41-46
    • Zamani, H.A.1    Rajabzadeh, G.2    Ganjali, M.R.3
  • 12
    • 33846567494 scopus 로고    scopus 로고
    • Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophores
    • Singh A.K., Gupta V.K., Gupta B. Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophores. Anal. Chim. Acta 2007, 585:171-178.
    • (2007) Anal. Chim. Acta , vol.585 , pp. 171-178
    • Singh, A.K.1    Gupta, V.K.2    Gupta, B.3
  • 13
    • 15744363494 scopus 로고    scopus 로고
    • Development of a Cr(III)-specific potentiometric sensor using Aurin tricarboxylic acid modified silica
    • Kumar Sharma R., Goel A. Development of a Cr(III)-specific potentiometric sensor using Aurin tricarboxylic acid modified silica. Anal. Chim. Acta 2005, 534:137-142.
    • (2005) Anal. Chim. Acta , vol.534 , pp. 137-142
    • Kumar Sharma, R.1    Goel, A.2
  • 15
    • 0037460633 scopus 로고    scopus 로고
    • New triiodomercurate-modified carbon paste electrode for the potentiometric determination of mercury
    • Abbas M.N., Mostafa G.A.E. New triiodomercurate-modified carbon paste electrode for the potentiometric determination of mercury. Anal. Chim. Acta 2003, 478:329-335.
    • (2003) Anal. Chim. Acta , vol.478 , pp. 329-335
    • Abbas, M.N.1    Mostafa, G.A.E.2
  • 16
    • 0020912222 scopus 로고
    • Carbon substrate ion selective electrod ion sel
    • Midgley D., Mulcahy D.E. Carbon substrate ion selective electrod ion sel. Electrode Rev. 1983, 5:165-241.
    • (1983) Electrode Rev. , vol.5 , pp. 165-241
    • Midgley, D.1    Mulcahy, D.E.2
  • 17
    • 0035974959 scopus 로고    scopus 로고
    • Differential pulse anodic stripping voltammetric determination of lead(II) with a 1,4-bis(prop-2′-enyloxy)-9,10-anthraquinone modified carbon paste electrode
    • -305-312
    • Mousavi M.F., Rahmani S.M., Golabi M., Shamsipur M., Sharghi H. Differential pulse anodic stripping voltammetric determination of lead(II) with a 1,4-bis(prop-2′-enyloxy)-9,10-anthraquinone modified carbon paste electrode. Talanta 2001, 55. -305-312.
    • (2001) Talanta , vol.55
    • Mousavi, M.F.1    Rahmani, S.M.2    Golabi, M.3    Shamsipur, M.4    Sharghi, H.5
  • 18
    • 18844408629 scopus 로고    scopus 로고
    • A selective modified carbon paste electrode for determination of cyanide using tetra-3,4-pyridinoporphyrazinato cobalt(II)
    • Abbaspour A., Asadi M., Ghaffarinejad A., Safaei E. A selective modified carbon paste electrode for determination of cyanide using tetra-3,4-pyridinoporphyrazinato cobalt(II). Talanta 2005, 66:931-936.
    • (2005) Talanta , vol.66 , pp. 931-936
    • Abbaspour, A.1    Asadi, M.2    Ghaffarinejad, A.3    Safaei, E.4
  • 19
    • 77349104865 scopus 로고    scopus 로고
    • Carbon paste electrode in electroanalytical chemistry
    • Vytras K., Svancara I., Metelka R. Carbon paste electrode in electroanalytical chemistry. J. Serbian Chem. Soc. 2009, 74:1021-1033.
    • (2009) J. Serbian Chem. Soc. , vol.74 , pp. 1021-1033
    • Vytras, K.1    Svancara, I.2    Metelka, R.3
  • 20
    • 37349052195 scopus 로고    scopus 로고
    • A new chemically modified carbon paste electrode for determination of copper based on N,N′-disalicylidenehexameythylenediaminate copper(II) complex
    • Abu-Shawish H.M., Saadeh S.M. A new chemically modified carbon paste electrode for determination of copper based on N,N′-disalicylidenehexameythylenediaminate copper(II) complex. Sens. Lett. 2007, 5:565-571.
    • (2007) Sens. Lett. , vol.5 , pp. 565-571
    • Abu-Shawish, H.M.1    Saadeh, S.M.2
  • 21
    • 0037016292 scopus 로고    scopus 로고
    • Chemically modified carbon paste electrode for determination of copper (II) by potentiometric method
    • Abbaspour A., Moosavi S.M.M. Chemically modified carbon paste electrode for determination of copper (II) by potentiometric method. Talanta 2002, 56:91-96.
    • (2002) Talanta , vol.56 , pp. 91-96
    • Abbaspour, A.1    Moosavi, S.M.M.2
  • 22
    • 0028797922 scopus 로고
    • Role of axial ligation on potentiometric response of Co(III) tetraphenylporphyrin-doped polymeric membranes to nitrite ions
    • Meyerhoff M.E. Role of axial ligation on potentiometric response of Co(III) tetraphenylporphyrin-doped polymeric membranes to nitrite ions. Anal. Chim. Acta 1995, 300:33-43.
    • (1995) Anal. Chim. Acta , vol.300 , pp. 33-43
    • Meyerhoff, M.E.1
  • 23
    • 0035869261 scopus 로고    scopus 로고
    • Iron(II) phthalocyanine-modified carbon-paste electrode for potentiometric detection of ascorbic acid
    • Amini1 M.K., Shahrokhian S., Tangestaninejad S., Mirkhani V. Iron(II) phthalocyanine-modified carbon-paste electrode for potentiometric detection of ascorbic acid. Anal. Biochem. 2001, 290:277-282.
    • (2001) Anal. Biochem. , vol.290 , pp. 277-282
    • Amini1, M.K.1    Shahrokhian, S.2    Tangestaninejad, S.3    Mirkhani, V.4
  • 24
    • 84987573898 scopus 로고
    • Sensors based on carbon paste in electrochemical analysis: a review with particular emphasis on the period 1990-1993
    • Kalcher K., Kauffmann J.M., Wang J., Svancara I., Vytras K., Neubold C., Yang Z.P. Sensors based on carbon paste in electrochemical analysis: a review with particular emphasis on the period 1990-1993. Electroanalysis 1995, 7:5-22.
    • (1995) Electroanalysis , vol.7 , pp. 5-22
    • Kalcher, K.1    Kauffmann, J.M.2    Wang, J.3    Svancara, I.4    Vytras, K.5    Neubold, C.6    Yang, Z.P.7
  • 25
    • 5144229636 scopus 로고    scopus 로고
    • Determination of l-histidine by modified carbon paste electrode using tetra-3,4-pyridinoporphirazinatocopper(II)
    • Abbaspour A., Ghaffarinejad A., Safaei E. Determination of l-histidine by modified carbon paste electrode using tetra-3,4-pyridinoporphirazinatocopper(II). Talanta 2004, 64:1036-1040.
    • (2004) Talanta , vol.64 , pp. 1036-1040
    • Abbaspour, A.1    Ghaffarinejad, A.2    Safaei, E.3
  • 26
    • 16644373048 scopus 로고    scopus 로고
    • Cyclam modified carbon paste electrode as a potentiometric sensor for determination of cobalt(II) ions
    • Pouretedal H.R., Keshavarz M.H. Cyclam modified carbon paste electrode as a potentiometric sensor for determination of cobalt(II) ions. Chem. Res. Chin. Univ. 2005, 21:28-31.
    • (2005) Chem. Res. Chin. Univ. , vol.21 , pp. 28-31
    • Pouretedal, H.R.1    Keshavarz, M.H.2
  • 27
    • 77951499307 scopus 로고    scopus 로고
    • Design and construction of azide carbon paste selective electrode based on a new schiff's base complex of iron, IEEE Sens. J., in press.
    • M. Ghaedi, A. Shokrollahi, M. Montazerozohori, S. Derki, Design and construction of azide carbon paste selective electrode based on a new schiff's base complex of iron, IEEE Sens. J., in press.
    • Ghaedi, M.1    Shokrollahi, A.2    Montazerozohori, M.3    Derki, S.4
  • 28
    • 67349261548 scopus 로고    scopus 로고
    • Flame atomic absorption spectrometric determination of zinc, nickel, iron and lead in different matrixes after solid phase extraction on sodium dodecyl sulfate (SDS)-coated alumina as their bis (2-hydroxyacetophenone)-1, 3-propanediimine chelates
    • Ghaedi M., Tavallali M.H., Shokrollahi A., Zahedi M., Montazerozohori M., Soylak M. Flame atomic absorption spectrometric determination of zinc, nickel, iron and lead in different matrixes after solid phase extraction on sodium dodecyl sulfate (SDS)-coated alumina as their bis (2-hydroxyacetophenone)-1, 3-propanediimine chelates. J. Hazard. Mater. 2009, 166:1441-1448.
    • (2009) J. Hazard. Mater. , vol.166 , pp. 1441-1448
    • Ghaedi, M.1    Tavallali, M.H.2    Shokrollahi, A.3    Zahedi, M.4    Montazerozohori, M.5    Soylak, M.6
  • 29
    • 34548804464 scopus 로고    scopus 로고
    • Potentiometric and spectrophotometric studies of copper(II) complexes of some ligands in aqueous and nonaqueous solution
    • Shokrollahi A., Ghaedi M., Ghaedi H. Potentiometric and spectrophotometric studies of copper(II) complexes of some ligands in aqueous and nonaqueous solution. J. Chin. Chem. Soc. 2007, 54:933-940.
    • (2007) J. Chin. Chem. Soc. , vol.54 , pp. 933-940
    • Shokrollahi, A.1    Ghaedi, M.2    Ghaedi, H.3
  • 30
    • 33947290546 scopus 로고
    • A general purpose curvefitting program for class and research use
    • Nicely V.A., Dye J.I. A general purpose curvefitting program for class and research use. J. Chem. Educ. 1971, 48:443-448.
    • (1971) J. Chem. Educ. , vol.48 , pp. 443-448
    • Nicely, V.A.1    Dye, J.I.2
  • 31
    • 0027325714 scopus 로고
    • Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors
    • Rosatzin T., Bakker E., Suzuki K., Simon W. Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors. Anal. Chim. Acta 1993, 280:197-208.
    • (1993) Anal. Chim. Acta , vol.280 , pp. 197-208
    • Rosatzin, T.1    Bakker, E.2    Suzuki, K.3    Simon, W.4
  • 32
    • 0035708911 scopus 로고    scopus 로고
    • Carbon paste electrodes in modern electroanalysis
    • Svancara I., Vytras K., Barek J., Zima J. Carbon paste electrodes in modern electroanalysis. Crit. Rev. 2001, 31:311-346.
    • (2001) Crit. Rev. , vol.31 , pp. 311-346
    • Svancara, I.1    Vytras, K.2    Barek, J.3    Zima, J.4
  • 33
    • 0037784479 scopus 로고
    • Selectivity coefficients for ion-selective electrodes: recommended methods for reporting KA Bpot values (technical report)
    • Umezawa Y., Umezawa K., Sato H. Selectivity coefficients for ion-selective electrodes: recommended methods for reporting KA Bpot values (technical report). Pure Appl. Chem. 1995, 67:507.
    • (1995) Pure Appl. Chem. , vol.67 , pp. 507
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3
  • 34
    • 0002232006 scopus 로고    scopus 로고
    • Selectivity of liquid membrane ion-selective electrodes
    • Bakker E. Selectivity of liquid membrane ion-selective electrodes. Electroanalysis 1997, 9:7-12.
    • (1997) Electroanalysis , vol.9 , pp. 7-12
    • Bakker, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.