메뉴 건너뛰기




Volumn 21, Issue 3, 2010, Pages 871-878

Time-dependent failure in load-bearing polymers: A potential hazard in structural applications of polylactides

Author keywords

[No Author keywords available]

Indexed keywords

CLINICAL APPLICATION; CLINICAL STUDY; COMPRESSION TESTS; DEFORMATION KINETICS; GLASSY POLYMERS; HIGH MECHANICAL STRENGTH; HIGHER YIELD; IN-VIVO; KINETIC BEHAVIOUR; LACTIDES; LOAD-BEARING; LOADING RATE; LONG TERM PERFORMANCE; MECHANICAL INTEGRITY; MOLECULAR MOBILITY; PLLA; POLY LACTIDE; POLYLACTIDES; POTENTIAL HAZARDS; PRE-CLINICAL; PROOF OF PRINCIPLES; RESORBABLE; SPINAL CAGES; SPINAL FUSION; SPINAL IMPLANT; STATIC LOADING; STATIC STRESS; STRUCTURAL APPLICATIONS; TIME DEPENDENT FAILURE; TIME-DEPENDENT BEHAVIOUR;

EID: 77951256259     PISSN: 09574530     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10856-009-3921-z     Document Type: Conference Paper
Times cited : (31)

References (36)
  • 1
    • 0348223825 scopus 로고    scopus 로고
    • Lumbar intervertebral body fusion cages: Histological evaluation of clinically failed cages retrieved from humans
    • Togawa D, Bauer TW, Lieberman IH, et al. Lumbar intervertebral body fusion cages: histological evaluation of clinically failed cages retrieved from humans. J Bone Joint Surg Am. 2004;86-A:70-9. (Pubitemid 38057339)
    • (2004) Journal of Bone and Joint Surgery - Series A , vol.86 , Issue.1 , pp. 70-79
    • Togawa, D.1    Bauer, T.W.2    Lieberman, I.H.3    Sakai, H.4
  • 2
    • 14744296571 scopus 로고    scopus 로고
    • Three- to six-year follow-up of stand-alone BAK cages implanted by a single surgeon
    • DOI 10.1016/j.spinee.2004.06.021, PII S1529943004006023
    • G Button M Gupta C Barrett, et al. 2005 Three- to six-year follow-up of stand-alone BAK cages implanted by a single surgeon Spine J 5 155 160 10.1016/j.spinee.2004.06.021 15749615 (Pubitemid 40331435)
    • (2005) Spine Journal , vol.5 , Issue.2 , pp. 155-160
    • Button, G.1    Gupta, M.2    Barrett, C.3    Cammack, P.4    Benson, D.5
  • 3
    • 33645750310 scopus 로고    scopus 로고
    • Unilateral transforaminal lumbar interbody fusion and bilateral anterior-column fixation with two Brantigan I/F cages per level: Clinical outcomes during a minimum 2-year follow-up period
    • DOI 10.3171/spi.2006.4.3.198
    • H Taneichi K Suda T Kajino, et al. 2006 Unilateral transforaminal lumbar interbody fusion and bilateral anterior-column fixation with two Brantigan I/F cages per level: clinical outcomes during a minimum 2-year follow-up period J Neurosurg Spine 4 198 205 10.3171/spi.2006.4.3.198 16572618 (Pubitemid 47325470)
    • (2006) Journal of Neurosurgery: Spine , vol.4 , Issue.3 , pp. 198-205
    • Taneichi, H.1    Suda, K.2    Kajino, T.3    Matsumura, A.4    Moridaira, H.5    Kaneda, K.6
  • 4
    • 0028600649 scopus 로고
    • Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases
    • 10.1097/00007632-199412150-00007 1:STN:280:DyaK2M3gslyrtA%3D%3D 7899978
    • A Ohlin M Karlsson H Duppe, et al. 1994 Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases Spine 19 2774 2779 10.1097/00007632-199412150-00007 1:STN:280: DyaK2M3gslyrtA%3D%3D 7899978
    • (1994) Spine , vol.19 , pp. 2774-2779
    • Ohlin, A.1    Karlsson, M.2    Duppe, H.3
  • 5
    • 0034214346 scopus 로고    scopus 로고
    • Lumbar interbody fusion using the Brantigan I/F Cage for posterior lumbar interbody fusion and the Variable Pedicle Screw Placement System: Two- year results from a Food and Drug Administration investigational device exemption clinical trial
    • DOI 10.1097/00007632-200006010-00017
    • JW Brantigan AD Steffee ML Lewis, et al. 2000 Lumbar interbody fusion using the Brantigan I/F cage for posterior lumbar interbody fusion and the variable pedicle screw placement system: two-year results from a Food and Drug Administration investigational device exemption clinical trial Spine 25 1437 1446 10.1097/00007632-200006010-00017 1:STN:280:DC%2BD3c3ptFemsQ%3D%3D 10828927 (Pubitemid 30353830)
    • (2000) Spine , vol.25 , Issue.11 , pp. 1437-1446
    • Brantigan, J.W.1    Steffee, A.D.2    Lewis, M.L.3    Quinn, L.M.4    Persenaire, J.M.5
  • 7
    • 0036534292 scopus 로고    scopus 로고
    • The effect of cage stiffness on the rate of lumbar interbody fusion: An in vivo model using poly(L-lactic acid) and titanium cages
    • DOI 10.1097/00007632-200204010-00003
    • M van Dijk TH Smit S Sugihara, et al. 2002 The effect of cage stiffness on the rate of lumbar interbody fusion: an in vivo model using poly(l-lactic acid) and titanium cages Spine 27 682 688 10.1097/00007632-200204010-00003 11923659 (Pubitemid 34259933)
    • (2002) Spine , vol.27 , Issue.7 , pp. 682-688
    • Van Dijk, M.1    Smit, T.H.2    Sugihara, S.3    Burger, E.H.4    Wuisman, P.I.5
  • 8
    • 0034580276 scopus 로고    scopus 로고
    • Synthetic biodegradable polymers as orthopedic devices
    • 10.1016/S0142-9612(00)00101-0 1:CAS:528:DC%2BD3cXmslKmtrc%3D 11055281
    • JC Middleton AJ Tipton 2000 Synthetic biodegradable polymers as orthopedic devices Biomaterials 21 2335 2346 10.1016/S0142-9612(00)00101-0 1:CAS:528:DC%2BD3cXmslKmtrc%3D 11055281
    • (2000) Biomaterials , vol.21 , pp. 2335-2346
    • Middleton, J.C.1    Tipton, A.J.2
  • 9
    • 33645048705 scopus 로고    scopus 로고
    • Bioresorbable polymers: Heading for a new generation of spinal cages
    • 10.1007/s00586-005-1003-6 1:STN:280:DC%2BD283gvVGitA%3D%3D 16292588
    • PI Wuisman TH Smit 2006 Bioresorbable polymers: heading for a new generation of spinal cages Eur Spine J 15 133 148 10.1007/s00586-005-1003-6 1:STN:280:DC%2BD283gvVGitA%3D%3D 16292588
    • (2006) Eur Spine J , vol.15 , pp. 133-148
    • Wuisman, P.I.1    Smit, T.H.2
  • 10
    • 0030038462 scopus 로고    scopus 로고
    • Poly(L-lactide) implants for repair of human orbital floor defects: Clinical and magnetic resonance imaging evaluation of long-term results
    • DOI 10.1016/S0278-2391(96)90292-X
    • FW Cordewener RR Bos FR Rozema, et al. 1996 Poly(l-lactide) implants for repair of human orbital floor defects: clinical and magnetic resonance imaging evaluation of long-term results J Oral Maxillofac Surg 54 9 13 10.1016/S0278-2391(96)90292-X 1:STN:280:DyaK287jsFSiuw%3D%3D 8531006 (Pubitemid 26013824)
    • (1996) Journal of Oral and Maxillofacial Surgery , vol.54 , Issue.1 , pp. 9-13
    • Cordewener, F.W.1    Bos, R.R.M.2    Rozema, F.R.3    Houtman, W.A.4
  • 11
    • 33845414029 scopus 로고    scopus 로고
    • Application of polylactides in spinal cages: Studies in a goat model
    • DOI 10.1007/s10856-006-0597-5, Selected Papers from the 10th International Conference on Polymers in Medicine and Surgery, Cambridge UK, 2004
    • TH Smit MR Krijnen DM van Dijk, et al. 2006 Application of polylactides in spinal cages: studies in a goat model J Mater Sci Mater Med 17 1237 1244 10.1007/s10856-006-0597-5 1:CAS:528:DC%2BD28Xht1KisbvI 17143754 (Pubitemid 44900622)
    • (2006) Journal of Materials Science: Materials in Medicine , vol.17 , Issue.12 , pp. 1237-1244
    • Smit, T.H.1    Krijnen, M.R.2    Van Dijk, M.3    Wuisman, P.I.J.M.4
  • 12
    • 0036894574 scopus 로고    scopus 로고
    • Bioabsorbable poly-L-lactic acid cages for lumbar interbody fusion three-year follow-up radiographic, histologic, and histomorphometric analysis in goats
    • DOI 10.1097/00007632-200212010-00010
    • M van Dijk TH Smit EH Burger, et al. 2002 Bioabsorbable poly-l-lactic acid cages for lumbar interbody fusion: three-year follow-up radiographic, histologic, and histomorphometric analysis in goats Spine 27 2706 2714 10.1097/00007632-200212010-00010 12461397 (Pubitemid 35425325)
    • (2002) Spine , vol.27 , Issue.23 , pp. 2706-2714
    • Van Dijk, M.1    Smit, T.H.2    Burger, E.H.3    Wuisman, P.I.4
  • 14
    • 0027308691 scopus 로고
    • Foreign body reactions to resorbable poly(l-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures
    • 1:STN:280:DyaK3s3mtVGluw%3D%3D 8492205
    • EJ Bergsma FR Rozema RR Bos, et al. 1993 Foreign body reactions to resorbable poly(l-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures J Oral Maxillofac Surg 51 666 670 1:STN:280:DyaK3s3mtVGluw%3D%3D 8492205
    • (1993) J Oral Maxillofac Surg , vol.51 , pp. 666-670
    • Bergsma, E.J.1    Rozema, F.R.2    Bos, R.R.3
  • 15
    • 0028878553 scopus 로고
    • Late degradation tissue response to poly(l-lactide) bone plates and screws
    • 10.1016/0142-9612(95)91092-D 1:CAS:528:DyaK2MXjvVGiu70%3D 7718688
    • JE Bergsma WC de Bruijn FR Rozema, et al. 1995 Late degradation tissue response to poly(l-lactide) bone plates and screws Biomaterials 16 25 31 10.1016/0142-9612(95)91092-D 1:CAS:528:DyaK2MXjvVGiu70%3D 7718688
    • (1995) Biomaterials , vol.16 , pp. 25-31
    • Bergsma, J.E.1    De Bruijn, W.C.2    Rozema, F.R.3
  • 16
    • 0347623805 scopus 로고    scopus 로고
    • Osteoarthritis of the ankle after foreign-body reaction to absorbable pins and screws
    • DOI 10.1302/0301-620X.80B2.8302
    • OM Bostman 1998 Osteoarthritis of the ankle after foreign-body reaction to absorbable pins and screws: a three- to nine-year follow-up study J Bone Joint Surg Br 80 333 338 10.1302/0301-620X.80B2.8302 1:STN:280: DyaK1c3gs1Gnug%3D%3D 9546472 (Pubitemid 28140383)
    • (1998) Journal of Bone and Joint Surgery - Series B , vol.80 , Issue.2 , pp. 333-338
    • Bostman, O.M.1
  • 17
    • 0347623805 scopus 로고    scopus 로고
    • Osteoarthritis of the ankle after foreign-body reaction to absorbable pins and screws
    • DOI 10.1302/0301-620X.80B2.8302
    • OM Bostman HK Pihlajamaki 1998 Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw. A case report J Bone Joint Surg Am 80 1791 1794 10.1302/0301-620X.80B2.8302 1:STN:280: DyaK1M%2FptFWltA%3D%3D 9875938 (Pubitemid 28140383)
    • (1998) Journal of Bone and Joint Surgery - Series B , vol.80 , Issue.2 , pp. 333-338
    • Bostman, O.M.1
  • 18
    • 0031202409 scopus 로고    scopus 로고
    • Lokale fremdkorperreaktionen auf biodegradierbare implantate: Eine klassifikation
    • DOI 10.1007/s001130050172
    • R Hoffmann A Weller HJ Helling, et al. 1997 Local foreign body reactions to biodegradable implants. A classification Unfallchirurg 100 658 666 10.1007/s001130050172 1:STN:280:DyaK2svktlSkuw%3D%3D 9381215 (Pubitemid 27390746)
    • (1997) Unfallchirurg , vol.100 , Issue.8 , pp. 658-666
    • Hoffmann, R.1    Weiler, A.2    Helling, H.-J.3    Krettek, C.4    Rehm, K.E.5
  • 19
    • 0041876075 scopus 로고
    • (Co)polymers of l-lactice, 2 mechanical properties
    • 10.1002/macp.1994.021950516 1:CAS:528:DyaK2cXjt1Crs7o%3D
    • DW Grijpma AJ Pennings 1994 (Co)polymers of l-lactice, 2 Mechanical properties Macromol Chem Phys 195 1649 1663 10.1002/macp.1994.021950516 1:CAS:528:DyaK2cXjt1Crs7o%3D
    • (1994) Macromol Chem Phys , vol.195 , pp. 1649-1663
    • Grijpma, D.W.1    Pennings, A.J.2
  • 20
    • 24744441396 scopus 로고    scopus 로고
    • Novel bioabsorbable interbody fusion spacer-assisted fusion for correction of spinal deformity
    • 10.3171/foc.2003.14.1.12 15766218
    • RC Austin CL Branch Jr JT Alexander 2003 Novel bioabsorbable interbody fusion spacer-assisted fusion for correction of spinal deformity Neurosurg Focus 14 e11 10.3171/foc.2003.14.1.12 15766218
    • (2003) Neurosurg Focus , vol.14 , pp. 11
    • Austin, R.C.1    Branch Jr, C.L.2    Alexander, J.T.3
  • 21
    • 3042615093 scopus 로고    scopus 로고
    • Posterior lumbar interbody fusion with bioabsorbable spacers and local autograft in a series of 27 patients
    • 10.3171/foc.2004.16.3.9 15198496
    • DE Couture CL Branch Jr 2004 Posterior lumbar interbody fusion with bioabsorbable spacers and local autograft in a series of 27 patients Neurosurg Focus 16 E8 10.3171/foc.2004.16.3.9 15198496
    • (2004) Neurosurg Focus , vol.16 , pp. 8
    • Couture, D.E.1    Branch Jr, C.L.2
  • 22
    • 24744462801 scopus 로고    scopus 로고
    • Rapid subsidence in lumbar interbody spinal fusion with resorbable implants
    • Ref Type: Conference Proceeding
    • Herceg MB, Slosar PJ, Josey R. Rapid subsidence in lumbar interbody spinal fusion with resorbable implants. In: 19th Ann. meeting North American Spine Society; 2004. Ref Type: Conference Proceeding.
    • (2004) 19th Ann. Meeting North American Spine Society
    • Herceg, M.B.1    Slosar, P.J.2    Josey, R.3
  • 23
    • 64849116039 scopus 로고    scopus 로고
    • Posterior lumbar interbody fusion using nonresorbable poly-ether-ether-ketone versus resorbable poly-l-lactide-co-d,l-lactide fusion devices: A prospective, randomized study to assess fusion and clinical outcome
    • (Phila Pa 1976)
    • Jiya T, Smit T, Deddens J, et al. Posterior lumbar interbody fusion using nonresorbable poly-ether-ether-ketone versus resorbable poly-l-lactide-co-d,l- lactide fusion devices: a prospective, randomized study to assess fusion and clinical outcome. Spine (Phila Pa 1976). 2009;34:233-7.
    • (2009) Spine , vol.34 , pp. 233-237
    • Jiya, T.1    Smit, T.2    Deddens, J.3
  • 24
    • 3042511491 scopus 로고    scopus 로고
    • Lumbar interbody fusion after treatment with recombinant human bone morphogenetic protein-2 added to poly(l-lactide-co-d,l-lactide) bioresorbable implants
    • 15198497
    • TH Lanman TJ Hopkins 2004 Lumbar interbody fusion after treatment with recombinant human bone morphogenetic protein-2 added to poly(l-lactide-co-d,l- lactide) bioresorbable implants Neurosurg Focus 16 E9 15198497
    • (2004) Neurosurg Focus , vol.16 , pp. 9
    • Lanman, T.H.1    Hopkins, T.J.2
  • 26
    • 77951253494 scopus 로고    scopus 로고
    • Compressive strength retention of 70:30 poly(l-lactide-co-d,l-lactide) following real time ageing
    • Minneapolis: Society for Biomaterials Ref Type: Abstract
    • Cornwall GB, Thomas KA, McManus AJ. Compressive strength retention of 70:30 poly(l-lactide-co-d,l-lactide) following real time ageing. In: Society for biomaterials 29th annual meeting transactions. Minneapolis: Society for Biomaterials; 2003. p. 393. Ref Type: Abstract.
    • (2003) Society for Biomaterials 29th Annual Meeting Transactions , pp. 393
    • Cornwall, G.B.1    Thomas, K.A.2    McManus, A.J.3
  • 27
    • 25844485461 scopus 로고    scopus 로고
    • Strength retention of 70:30 poly(l-lactide-co-d,l-lactide) following real-time aging
    • 16001395
    • RC Moser AJ McManus SL Riley, et al. 2005 Strength retention of 70:30 poly(l-lactide-co-d,l-lactide) following real-time aging J Biomed Mater Res B Appl Biomater 75 56 63 16001395
    • (2005) J Biomed Mater Res B Appl Biomater , vol.75 , pp. 56-63
    • Moser, R.C.1    McManus, A.J.2    Riley, S.L.3
  • 28
    • 33745238394 scopus 로고    scopus 로고
    • Radiographic, histologic, and chemical evaluation of bioresorbable 70/30 poly-L-lactide-CO-D, L-lactide interbody fusion cages in a goat model
    • DOI 10.1097/01.brs.0000221984.12004.3b, PII 0000763220060615000009
    • MR Krijnen MG Mullender TH Smit, et al. 2006 Radiographic, histologic, and chemical evaluation of bioresorbable 70/30 poly-l-lactide-co-d,l-lactide interbody fusion cages in a goat model Spine 31 1559 1567 10.1097/01.brs. 0000221984.12004.3b 16778688 (Pubitemid 43916768)
    • (2006) Spine , vol.31 , Issue.14 , pp. 1559-1567
    • Krijnen, M.R.1    Mullender, M.G.2    Smit, T.H.3    Everts, V.4    Wuisman, P.I.J.M.5
  • 29
    • 37649022720 scopus 로고    scopus 로고
    • Time-dependent mechanical strength of 70/30 Poly(l, dl-lactide): Shedding light on the premature failure of degradable spinal cages
    • 10.1097/BRS.0b013e31815e39df 18165743
    • TH Smit TA Engels PI Wuisman, et al. 2008 Time-dependent mechanical strength of 70/30 Poly(l, dl-lactide): shedding light on the premature failure of degradable spinal cages Spine 33 14 18 10.1097/BRS.0b013e31815e39df 18165743
    • (2008) Spine , vol.33 , pp. 14-18
    • Smit, T.H.1    Engels, T.A.2    Wuisman, P.I.3
  • 30
    • 23844548501 scopus 로고    scopus 로고
    • Modeling of the postyield response of glassy polymers: Influence of thermomechanical history
    • DOI 10.1021/ma050498v
    • ETJ Klompen T Engels LE Govaert, et al. 2005 Modeling of the postyield response of glassy polymers: influence of thermomechanical history Macromolecules 38 6997 7008 10.1021/ma050498v 1:CAS:528:DC%2BD2MXlvVKhtb0%3D 2005MaMol..38.6997K (Pubitemid 41181646)
    • (2005) Macromolecules , vol.38 , Issue.16 , pp. 6997-7008
    • Klompen, E.T.J.1    Engels, T.A.P.2    Govaert, L.E.3    Meijer, H.E.H.4
  • 31
    • 0037455697 scopus 로고    scopus 로고
    • Multi-scale analysis of mechanical properties of amorphous polymer systems
    • 10.1002/macp.200290080 1:CAS:528:DC%2BD3sXitlOisb4%3D
    • HEH Meijer LE Govaert 2003 Multi-scale analysis of mechanical properties of amorphous polymer systems Macromol Chem Phys 204 274 288 10.1002/macp. 200290080 1:CAS:528:DC%2BD3sXitlOisb4%3D
    • (2003) Macromol Chem Phys , vol.204 , pp. 274-288
    • Meijer, H.E.H.1    Govaert, L.E.2
  • 32
    • 77951258051 scopus 로고    scopus 로고
    • Time-dependent failure of amorphous polylactides in static loading conditions
    • Engels TA, Sontjens SH, Smit TH, et al. Time-dependent failure of amorphous polylactides in static loading conditions. J Mater Sci Mater Med. 2009.
    • (2009) J Mater Sci Mater Med.
    • Engels, T.A.1    Sontjens, S.H.2    Smit, T.H.3
  • 33
    • 34147092626 scopus 로고    scopus 로고
    • Sterilization and strength of 70/30 polylactide cages: E-beam vs. ethylene oxide
    • Smit TH, Thomas KA, Hoogendoorn RJ, et al. Sterilization and strength of 70/30 polylactide cages: e-beam vs. ethylene oxide. Spine. 2007;32.
    • (2007) Spine , pp. 32
    • Smit, T.H.1    Thomas, K.A.2    Hoogendoorn, R.J.3
  • 34
    • 0030107035 scopus 로고    scopus 로고
    • The strain-rate and temperature dependence of the mechanical properties of polyetherketone and polyetheretherketone
    • S Hamdan GM Swallowe 1996 The strain-rate and temperature dependence of the mechanical properties of polyetherketone and polyetheretherketone J Mater Sci 31 1415 1423 10.1007/BF00357847 1:CAS:528:DyaK28XhvVGgtLo%3D 1996JMatS..31.1415H (Pubitemid 126711494)
    • (1996) Journal of Materials Science , vol.31 , Issue.6 , pp. 1415-1423
    • Hamdan, S.1    Swallowe, G.M.2
  • 36
    • 24344478106 scopus 로고    scopus 로고
    • Mechanical performance of polymer systems: The relation between structure and properties
    • DOI 10.1016/j.progpolymsci.2005.06.009, PII S0079670005000717, Plenary Lectures
    • H Meyer LE Govaert 2005 Mechanical performance of polymer systems: the relation between structure and properties Prog Polym Sci 30 915 938 10.1016/j.progpolymsci.2005.06.009 (Pubitemid 41261391)
    • (2005) Progress in Polymer Science (Oxford) , vol.30 , Issue.8-9 , pp. 915-938
    • Meijer, H.E.H.1    Govaert, L.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.