-
3
-
-
33745007371
-
The stability of three commercially available implants used in medial opening wedge high tibial osteotomy
-
Dorsey WO, Miller BS, Tadje JP, Bryant CR (2006) The stability of three commercially available implants used in medial opening wedge high tibial osteotomy. J Knee Surg 19: 95-98.
-
(2006)
J Knee Surg
, vol.19
, pp. 95-98
-
-
Dorsey, W.O.1
Miller, B.S.2
Tadje, J.P.3
Bryant, C.R.4
-
4
-
-
0032693161
-
Primary stability of different implants used in conjunction with high tibial osteotomy
-
Flamme CH, Kohn D, Kirsch L, Hurschler C (1999) Primary stability of different implants used in conjunction with high tibial osteotomy. Arch Orthop Trauma Surg 119: 450-455.
-
(1999)
Arch Orthop Trauma Surg
, vol.119
, pp. 450-455
-
-
Flamme, C.H.1
Kohn, D.2
Kirsch, L.3
Hurschler, C.4
-
5
-
-
0030340307
-
Open wedge high tibial osteotomy using fractioned drill osteotomy: A surgical modification that lowers the complication rate
-
Flierl S, Sabo D, Hornig K, Perlick L (1996) Open wedge high tibial osteotomy using fractioned drill osteotomy: a surgical modification that lowers the complication rate. Knee Surg Sports Traumatol Arthrosc 4: 149-153.
-
(1996)
Knee Surg Sports Traumatol Arthrosc
, vol.4
, pp. 149-153
-
-
Flierl, S.1
Sabo, D.2
Hornig, K.3
Perlick, L.4
-
6
-
-
1442325509
-
Medial opening wedge high tibial osteotomy: How I do it
-
Fowler P, Tan L, Brown G (2000) Medial opening wedge high tibial osteotomy: how I do it. Oper Tech Sports Med 8: 32-38.
-
(2000)
Oper Tech Sports Med
, vol.8
, pp. 32-38
-
-
Fowler, P.1
Tan, L.2
Brown, G.3
-
7
-
-
0018648753
-
The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints
-
Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10: 585-608.
-
(1979)
Orthop Clin North Am
, vol.10
, pp. 585-608
-
-
Fujisawa, Y.1
Masuhara, K.2
Shiomi, S.3
-
8
-
-
22544438849
-
Accuracy and initial stability of open- and closed-wedge high tibial osteotomy: A cadaveric RSA study
-
Gaasbeek RD, Welsing RT, Verdonschot N, Rijnberg WJ, van Loon CJ, van Kampen A (2005) Accuracy and initial stability of open- and closed-wedge high tibial osteotomy: a cadaveric RSA study. Knee Surg Sports Traumatol Arthrosc 13: 689-694.
-
(2005)
Knee Surg Sports Traumatol Arthrosc
, vol.13
, pp. 689-694
-
-
Gaasbeek, R.D.1
Welsing, R.T.2
Verdonschot, N.3
Rijnberg, W.J.4
van Loon, C.J.5
van Kampen, A.6
-
9
-
-
62949246527
-
Radiological assessment of osteo-arthrosis
-
Kellgren JH, Lawrence JS (1957) Radiological assessment of osteo-arthrosis. Ann Rheum Dis 16: 494-502.
-
(1957)
Ann Rheum Dis
, vol.16
, pp. 494-502
-
-
Kellgren, J.H.1
Lawrence, J.S.2
-
10
-
-
0142161636
-
Open-wedge high-tibial osteotomy with rigid plate fixation
-
Lobenhoffer P, De Simoni C, Staubli A (2002) Open-wedge high-tibial osteotomy with rigid plate fixation. Tech Knee Surg 1: 93-105.
-
(2002)
Tech Knee Surg
, vol.1
, pp. 93-105
-
-
Lobenhoffer, P.1
de Simoni, C.2
Staubli, A.3
-
12
-
-
25844503814
-
The effect of lateral cortex disruption and repair on the stability of the medial opening wedge high tibial osteotomy
-
Miller BS, Dorsey WO, Bryant CR, Austin JC (2005) The effect of lateral cortex disruption and repair on the stability of the medial opening wedge high tibial osteotomy. Am J Sports Med 33: 1552-1557.
-
(2005)
Am J Sports Med
, vol.33
, pp. 1552-1557
-
-
Miller, B.S.1
Dorsey, W.O.2
Bryant, C.R.3
Austin, J.C.4
-
13
-
-
24144457292
-
Fixation stability following high tibial osteotomy: A radiostereometric analysis
-
Pape D, Adam F, Seil R, Georg T, Kohn D (2005) Fixation stability following high tibial osteotomy: a radiostereometric analysis. J Knee Surg 18: 108-115.
-
(2005)
J Knee Surg
, vol.18
, pp. 108-115
-
-
Pape, D.1
Adam, F.2
Seil, R.3
Georg, T.4
Kohn, D.5
-
14
-
-
32044444121
-
Partial release of the superficial medial collateral ligament for open-wedge high tibial osteotomy. A human cadaver study evaluating medial joint opening by stress radiography
-
Pape D, Duchow J, Rupp S, Seil R, Kohn D (2006) Partial release of the superficial medial collateral ligament for open-wedge high tibial osteotomy. A human cadaver study evaluating medial joint opening by stress radiography. Knee Surg Sports Traumatol Arthrosc 14: 141-148.
-
(2006)
Knee Surg Sports Traumatol Arthrosc
, vol.14
, pp. 141-148
-
-
Pape, D.1
Duchow, J.2
Rupp, S.3
Seil, R.4
Kohn, D.5
-
15
-
-
0017832129
-
A stereophotogrammetric system for the study of human movements
-
Selvik G (1978) A stereophotogrammetric system for the study of human movements. Scand J Rehabil Med Suppl 6: 16-20.
-
(1978)
Scand J Rehabil Med Suppl
, vol.6
, pp. 16-20
-
-
Selvik, G.1
-
16
-
-
0021082479
-
A roentgen stereophotogrammetric system. Construction, calibration and technical accuracy
-
Selvik G, Alberius P, Aronson AS (1983) A roentgen stereophotogrammetric system. Construction, calibration and technical accuracy. Acta Radiol 24: 343-352.
-
(1983)
Acta Radiol
, vol.24
, pp. 343-352
-
-
Selvik, G.1
Alberius, P.2
Aronson, A.S.3
-
17
-
-
31544472827
-
Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy
-
Spahn G, Muckley T, Kahl E, Hofmann GO (2006) Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy. Clin Biomech 21: 272-278.
-
(2006)
Clin Biomech
, vol.21
, pp. 272-278
-
-
Spahn, G.1
Muckley, T.2
Kahl, E.3
Hofmann, G.O.4
-
18
-
-
4744356841
-
Open wedge high tibial osteotomy: Biomechanical investigation of the modified arthrex osteotomy plate and the tomofix plate
-
Stoffel K, Stachowiak G, Kuster M (2004) Open wedge high tibial osteotomy: biomechanical investigation of the modified arthrex osteotomy plate and the tomofix plate. Clin Biomech 19: 944-950.
-
(2004)
Clin Biomech
, vol.19
, pp. 944-950
-
-
Stoffel, K.1
Stachowiak, G.2
Kuster, M.3
-
19
-
-
0033145047
-
Biomechanical evaluation of a proximal tibial opening-wedge osteotomy plate
-
Stuart MJ, Beachy AM, Grabowski JJ, An KN, Kaufman KR (1999) Biomechanical evaluation of a proximal tibial opening-wedge osteotomy plate. Am J Knee Surg 12: 148-153.
-
(1999)
Am J Knee Surg
, vol.12
, pp. 148-153
-
-
Stuart, M.J.1
Beachy, A.M.2
Grabowski, J.J.3
An, K.N.4
Kaufman, K.R.5
-
20
-
-
24144447269
-
Guidelines for standardization of radiostereometry (RSA) of implants
-
Valstar ER, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J (2005) Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 76: 563-572.
-
(2005)
Acta Orthop
, vol.76
, pp. 563-572
-
-
Valstar, E.R.1
Gill, R.2
Ryd, L.3
Flivik, G.4
Borlin, N.5
Karrholm, J.6
-
22
-
-
33646175585
-
Biomechanical stability of a retrotubercle opening-wedge high tibial osteotomy
-
Zhim F, Laflamme GY, Viens H, Laflamme GH, Yahia L (2006) Biomechanical stability of a retrotubercle opening-wedge high tibial osteotomy. J Knee Surg 19: 28-321.
-
(2006)
J Knee Surg
, vol.19
, pp. 28-321
-
-
Zhim, F.1
Laflamme, G.Y.2
Viens, H.3
Laflamme, G.H.4
Yahia, L.5
|