Volumn , Issue , 2009, Pages 2548-2552

Basic evaluation of a C-shaped breast PET scanner

Author keywords

[No Author keywords available]

Indexed keywords

ACQUISITION TIME; BREAST CANCER; C-SHAPED; COUNT RATES; CRYSTAL ARRAYS; CRYSTAL ELEMENTS; DEPTH-OF-INTERACTION DETECTORS; DETECTOR MODULE; LARGE EFFECTIVE; LIGHT GUIDES; PET SCANNER; POSITION SENSITIVE PHOTOMULTIPLIER TUBE; POSITRON EMISSION TOMOGRAPHY SCANNERS; RING CONFIGURATION; SMALL LESIONS; SPATIAL RESOLUTION;

EID: 77951192958     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2009.5402027     Document Type: Conference Paper
Times cited : (40)

References (8)
  • 1
    • 70349644006 scopus 로고    scopus 로고
    • Clinical Imaging Characteristics of the Positron Emission Mammography Camera: PEM Flex Solo II
    • Oct.
    • L. MacDnald, et al, "Clinical Imaging Characteristics of the Positron Emission Mammography Camera: PEM Flex Solo II", The Journal of Medicine, vol.50, no.10, pp. 1666-1675, Oct. 2009.
    • (2009) The Journal of Medicine , vol.50 , Issue.10 , pp. 1666-1675
    • MacDnald, L.1
  • 2
    • 33645653260 scopus 로고    scopus 로고
    • Design and evaluation of the Clear-PEM scanner for positron emission mammography
    • Feb.
    • M. C. Abreu, et al. "Design and evaluation of the Clear-PEM scanner for positron emission mammography", IEEE Trans. Nucl. Sci., vol. 53, no. 1, pp.71-77, Feb. 2006.
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , Issue.1 , pp. 71-77
    • Abreu, M.C.1
  • 3
    • 69449092739 scopus 로고    scopus 로고
    • Initial Characterization of a Dedicated Breast PET/CT Scanner during Human Imaging
    • Sep.
    • S. L. Bowen, et al, "Initial Characterization of a Dedicated Breast PET/CT Scanner During Human Imaging", The Journal of Medicine, vol.50, no.9, pp. 1401-1408, Sep. 2009.
    • (2009) The Journal of Medicine , vol.50 , Issue.9 , pp. 1401-1408
    • Bowen, S.L.1
  • 4
    • 67649160219 scopus 로고    scopus 로고
    • Development of a C-shaped Breast PET Scanner Equipped with Four-Layer DOI Detectors
    • K. Kitamura, et al, "Development of a C-shaped Breast PET Scanner Equipped with Four-Layer DOI Detectors", IEEE MRBC 2008, Conf. Rec. MR10-2
    • IEEE MRBC 2008, Conf. Rec. MR10-2
    • Kitamura, K.1
  • 5
    • 48349138114 scopus 로고    scopus 로고
    • Sophisticated 32 X 32 X 4-Layer DOI Detector for High Resolution PEM Scanner
    • H. Tonami, et al., "Sophisticated 32 x 32 x 4-Layer DOI Detector for High Resolution PEM Scanner", IEEE NSS&MIC 2007, Conf. Rec., M19-151
    • IEEE NSS&MIC 2007, Conf. Rec., M19-151
    • Tonami, H.1
  • 6
    • 57849165504 scopus 로고    scopus 로고
    • A DOI-Dependent Extended Energy Window Method to Control Balance of Scatter and True Events
    • Oct.
    • E. Yoshida, et al. "A DOI-Dependent Extended Energy Window Method to Control Balance of Scatter and True Events", I IEEE Trans. Nucl. Sci., vol. 55, no.5, pp. 2475-2481, Oct. 2007.
    • (2007) I IEEE Trans. Nucl. Sci. , vol.55 , Issue.5 , pp. 2475-2481
    • Yoshida, E.1
  • 7
    • 48149083140 scopus 로고    scopus 로고
    • Reconstruction of 4-Layer DOI Detector Equipped C-Shaped PEM via List-Mode Iterative Algorithm
    • Y. Yamada, et al., "Reconstruction of 4-Layer DOI Detector Equipped C-Shaped PEM via List-Mode Iterative Algorithm", IEEE NSS&MIC 2007, Conf. Rec., M26-212
    • IEEE NSS&MIC 2007, Conf. Rec., M26-212
    • Yamada, Y.1
  • 8
    • 67649188769 scopus 로고    scopus 로고
    • MAP-EM Reconstruction using Uniform Background Template for Limited-Angle PEM
    • K. Kitamura, et al, "MAP-EM Reconstruction using Uniform Background Template for Limited-Angle PEM", IEEE MRBC 2008, Conf. Rec. MR06-341
    • IEEE MRBC 2008, Conf. Rec. MR06-341
    • Kitamura, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.