메뉴 건너뛰기




Volumn , Issue , 2009, Pages 3251-3255

Normalized metal artifact reduction (NMAR) in computed tomography

Author keywords

[No Author keywords available]

Indexed keywords

BONE STRUCTURE; CLINICAL DATA; COMPUTED TOMOGRAPHY; CT IMAGE; DIAGNOSTIC VALUE; ENDOPROSTHESES; FIELD OF MEASUREMENTS; INTERPOLATION SCHEMES; LENGTH NORMALIZATION; LINEAR INTERPOLATION; METAL ARTIFACT REDUCTION; METAL IMPLANTS; MULTI-THRESHOLD SEGMENTATION; PROJECTION DATA; SIMULATED DATA; SIMULATIONS AND MEASUREMENTS; SINOGRAMS; STANDARD METHOD;

EID: 77951163485     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2009.5401721     Document Type: Conference Paper
Times cited : (18)

References (13)
  • 1
    • 66749175872 scopus 로고    scopus 로고
    • Spurious structures created by interpolation-based CT metal artifact reduction
    • Mar
    • J. Müller and T. M. Buzug, "Spurious structures created by interpolation-based CT metal artifact reduction," SPIE Medical Imaging Proc., vol. 7258, no. 1, pp. 1Y1 - 1Y8, Mar. 2009.
    • (2009) SPIE Medical Imaging Proc. , vol.7258 , Issue.1
    • Müller, J.1    Buzug, T.M.2
  • 2
    • 0019839830 scopus 로고
    • An algorithm for the reduction of metal clip artifacts in CT reconstructions
    • Nov./Dec
    • G. H. Glover and N. J. Pelc, "An algorithm for the reduction of metal clip artifacts in CT reconstructions," Med. Phys., vol. 8, no. 6, pp. 799-807, Nov./Dec. 1981.
    • (1981) Med. Phys. , vol.8 , Issue.6 , pp. 799-807
    • Glover, G.H.1    Pelc, N.J.2
  • 3
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • Aug
    • W. A. Kalender, R. Hebel, and J. Ebersberger, "Reduction of CT artifacts caused by metallic implants," Radiology, vol. 164, no. 2, pp. 576-577, Aug. 1987.
    • (1987) Radiology , vol.164 , Issue.2 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 6
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering (MAF) for conventional and spiral single-slice, multi-slice and cone-beam CT
    • Apr
    • M. Kachelrieß, O. Watzke, and W. A. Kalender, "Generalized multi-dimensional adaptive filtering (MAF) for conventional and spiral single-slice, multi-slice and cone-beam CT," Med. Phys., vol. 28, no. 4, pp. 475-490, Apr. 2001.
    • (2001) Med. Phys. , vol.28 , Issue.4 , pp. 475-490
    • Kachelrieß, M.1    Watzke, O.2    Kalender, W.A.3
  • 8
    • 33746633331 scopus 로고    scopus 로고
    • Metal artifact reduction in ct using tissue-class modeling and adaptive prefiltering
    • M. Bal and L. Spies, "Metal artifact reduction in ct using tissue-class modeling and adaptive prefiltering," Medical Physics, vol. 33, no. 8, pp. 2852-2859, 2006.
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 2852-2859
    • Bal, M.1    Spies, L.2
  • 9
    • 77951163186 scopus 로고    scopus 로고
    • A pragmatic approach to metal artifact correction in medical CT
    • Nov
    • O. Watzke, M. Kachelrieß, and W. A. Kalender, "A pragmatic approach to metal artifact correction in medical CT," Radiology, vol. 221(P), pp. 544-545, Nov. 2001.
    • (2001) Radiology , vol.221 , Issue.P , pp. 544-545
    • Watzke, O.1    Kachelrieß, M.2    Kalender, W.A.3
  • 10
    • 0034351113 scopus 로고    scopus 로고
    • X-ray CT metal artifact reduction using wavelets: An application for imaging total hip prostheses
    • Dec
    • S. Zhao, D. D. Robertson, G. Wang, B. Whiting, and K. T. Bae, "X-ray CT metal artifact reduction using wavelets: An application for imaging total hip prostheses," IEEE Transactions on Medical Imaging, vol. 19, no. 12, pp. 1238-1247, Dec. 2000.
    • (2000) IEEE Transactions on Medical Imaging , vol.19 , Issue.12 , pp. 1238-1247
    • Zhao, S.1    Robertson, D.D.2    Wang, G.3    Whiting, B.4    Bae, K.T.5
  • 12
    • 0345708391 scopus 로고    scopus 로고
    • A new algorithm for metal artifact reduction in computed tomography: In vitro and in vivo evaluation after total hip replacement
    • Dec
    • A. H. Mahnken, R. Raupach, J. E. Wildberger, B. Jung, N. Heussen, T. G. Flohr, R. W. Günther, and S. Schaller, "A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement," Investigative Radiology, vol. 38, no. 12, pp. 769-775, Dec. 2003.
    • (2003) Investigative Radiology , vol.38 , Issue.12 , pp. 769-775
    • Mahnken, A.H.1    Raupach, R.2    Wildberger, J.E.3    Jung, B.4    Heussen, N.5    Flohr, T.G.6    Günther, R.W.7    Schaller, S.8
  • 13
    • 12744273446 scopus 로고    scopus 로고
    • X-ray CT high-density artefact suppression in the presence of bones
    • J. Wei, L. Chen, G. A. Sandison, Y. Liang, and L. X. Xu, "X-ray CT high-density artefact suppression in the presence of bones," Phys. Med. Biol., vol. 49, no. 24, pp. 5407-5418, 2004.
    • (2004) Phys. Med. Biol. , vol.49 , Issue.24 , pp. 5407-5418
    • Wei, J.1    Chen, L.2    Sandison, G.A.3    Liang, Y.4    Xu, L.X.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.