메뉴 건너뛰기




Volumn , Issue , 2009, Pages 4064-4067

GPU acceleration of a fully 3D iterative reconstruction software for PET using CUDA

Author keywords

[No Author keywords available]

Indexed keywords

BACKWARD PROJECTION; C LANGUAGE; CODE RUNNING; EXECUTION TIME; FORTRAN; GRAPHICS PROCESSING UNITS; ITERATIVE RECONSTRUCTION; MEMORY ALLOCATION; PERFORMANCE COMPARISON;

EID: 77951161074     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2009.5402402     Document Type: Conference Paper
Times cited : (6)

References (9)
  • 1
    • 33748566788 scopus 로고    scopus 로고
    • FIRST: Fast Iterative Reconstruction Software for (PET) Tomography
    • J. L. Herraiz et al., "FIRST: Fast Iterative Reconstruction Software for (PET) Tomography," Phys. Med. Biol., vol. 51, pp. 4547-4565, 2007.
    • (2007) Phys. Med. Biol. , vol.51 , pp. 4547-4565
    • Herraiz, J.L.1
  • 2
    • 35948991669 scopus 로고    scopus 로고
    • CUDA - Nvidia Corp.
    • CUDA - Nvidia Corp.: Nvidia CUDA Programming Guide v.2.3 (2009) - http://www.nvidia.com/object/cuda-home.html
    • (2009) Nvidia CUDA Programming Guide V.2.3
  • 3
    • 61449116964 scopus 로고    scopus 로고
    • Fast, accurate and shift-varying line projections for iterative reconstructions using the GPU
    • Mar
    • G. Pratx, G. Chinn, P.D. Olcott, and C.S. Levin, "Fast, accurate and shift-varying line projections for iterative reconstructions using the GPU," IEEE Trans. Med. Imag., vol 28(3), pp. 435-445, Mar 2009.
    • (2009) IEEE Trans. Med. Imag. , vol.28 , Issue.3 , pp. 435-445
    • Pratx, G.1    Chinn, G.2    Olcott, P.D.3    Levin, C.S.4
  • 5
    • 63649147667 scopus 로고    scopus 로고
    • PeneloPET, a Monte Carlo PET simulation toolkit based on PENELOPE
    • E. España et al., "PeneloPET, a Monte Carlo PET simulation toolkit based on PENELOPE," Phys. Med. Bio. vol. 54, pp. 1723-1742, 2009
    • (2009) Phys. Med. Bio. , vol.54 , pp. 1723-1742
    • España, E.1
  • 6
    • 70350635839 scopus 로고    scopus 로고
    • Design and perform evaluation of a coplanar multimodality scanner for rodents imaging
    • E. Lage et al., "Design and perform evaluation of a coplanar multimodality scanner for rodents imaging," Phys. Med. Biol, vol. 54, pp. 5427-5441, 2009.
    • (2009) Phys. Med. Biol , vol.54 , pp. 5427-5441
    • Lage, E.1
  • 7
    • 58149210333 scopus 로고    scopus 로고
    • PENELOPE: An algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter
    • J Baró et al., " PENELOPE: an algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter," Nucl Inst Meth In Phy Res B, vol. 100, pp. 31-46, 1996
    • (1996) Nucl Inst Meth in Phy Res B , vol.100 , pp. 31-46
    • Baró, J.1
  • 8
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • H. M. Hudson, and R. S. Larkin, "Accelerated image reconstruction using ordered subsets of projection data," IEEE Trans. Med. Imag., vol. 13, pp. 601-609, 1994
    • (1994) IEEE Trans. Med. Imag. , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 9
    • 77951147919 scopus 로고    scopus 로고
    • http://software.intel.com/en-us/intel-compilers


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.