메뉴 건너뛰기




Volumn , Issue , 2009, Pages 3517-3522

A new method for cupping and scatter precorrection for flat detector CT

Author keywords

Beam hardening; Computed tomography (CT); Cupping; Image correction; Scatter

Indexed keywords

BEAM HARDENING; BEAM HARDENING CORRECTION; BINARY TOMOGRAPHY; BOW TIE; CALIBRATION TECHNIQUES; COMPUTED TOMOGRAPHY; CONE-BEAM CT SCANNERS; CORRECTION MODELS; CT SCAN; FLAT DETECTORS; FLAT PANEL; HOMOGENEOUS OBJECTS; IMAGE CORRECTION; MEASURED DATA; NON-BINARY; PARAMETER SPACES; PREPROCESS; RATIONAL FUNCTION; SELF CALIBRATION; SIMULATED DATA; SIMULATION STUDIES; SMOOTHNESS CONSTRAINTS; VOLTAGE MODULATIONS; VOLTAGE VARIATION; X-RAY CT;

EID: 77951157928     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2009.5401805     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 2
    • 0017195533 scopus 로고
    • Beam hardening in x-ray reconstructive tomography
    • May
    • R. A. Brooks and G. D. Chiro, "Beam hardening in x-ray reconstructive tomography.," Phys Med Biol, vol. 21, pp. 390-398, May 1976.
    • (1976) Phys Med Biol , vol.21 , pp. 390-398
    • Brooks, R.A.1    Chiro, G.D.2
  • 3
    • 0033983855 scopus 로고    scopus 로고
    • An iterative approach to the beam hardening correction in cone beam CT
    • Jan
    • J. Hsieh, R. C. Molthen, C. A. Dawson, and R. H. Johnson, "An iterative approach to the beam hardening correction in cone beam CT," Med. Phys., vol. 27, pp. 23 - 29, Jan 2000.
    • (2000) Med. Phys. , vol.27 , pp. 23-29
    • Hsieh, J.1    Molthen, R.C.2    Dawson, C.A.3    Johnson, R.H.4
  • 5
    • 33646460131 scopus 로고    scopus 로고
    • Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography
    • May
    • M. Kachelrieß, K. Sourbelle, and W. A. Kalender, "Empirical cupping correction: a first-order raw data precorrection for cone-beam computed tomography," Med. Phys., vol. 33, pp. 1269-1274, May 2006.
    • (2006) Med. Phys. , vol.33 , pp. 1269-1274
    • Kachelrieß, M.1    Sourbelle, K.2    Kalender, W.A.3
  • 6
    • 0017810277 scopus 로고
    • A method for correcting bone induced artifacts in computed tomography scanners
    • Jan
    • P. M. Joseph and R. D. Spital, "A method for correcting bone induced artifacts in computed tomography scanners.," J Comput Assist Tomogr, vol. 2, pp. 100 - 108, Jan 1978.
    • (1978) J Comput Assist Tomogr , vol.2 , pp. 100-108
    • Joseph, P.M.1    Spital, R.D.2
  • 7
    • 0032605125 scopus 로고    scopus 로고
    • Efficient object scatter correction algorithm for third and fourth generation CT scanners
    • B. Ohnesorge, T. Flohr, and K. Klingenbeck-Regn, "Efficient object scatter correction algorithm for third and fourth generation CT scanners," European Radiology, vol. 9, no. 3, pp. 563-569, 1999.
    • (1999) European Radiology , vol.9 , Issue.3 , pp. 563-569
    • Ohnesorge, B.1    Flohr, T.2    Klingenbeck-Regn, K.3
  • 9
    • 33748518881 scopus 로고    scopus 로고
    • Combining deterministic and monte carlo calculations for fast estimation of scatter intensities in ct.
    • Sep
    • Y. Kyriakou, T. Riedel, and W. A. Kalender, "Combining deterministic and monte carlo calculations for fast estimation of scatter intensities in ct.," Phys. Med. Biol., vol. 51, pp. 4567-4586, Sep 2006.
    • (2006) Phys. Med. Biol. , vol.51 , pp. 4567-4586
    • Kyriakou, Y.1    Riedel, T.2    Kalender, W.A.3
  • 10
    • 0025756532 scopus 로고
    • Semiempirical model for generating tungsten target x-ray spectra
    • D. M. Tucker, G. T. Barnes, and D. P. Chakraborty, "Semiempirical model for generating tungsten target x-ray spectra," Med. Phys., vol. 18, no. 2, pp. 211 - 218, 1991.
    • (1991) Med. Phys. , vol.18 , Issue.2 , pp. 211-218
    • Tucker, D.M.1    Barnes, G.T.2    Chakraborty, D.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.