메뉴 건너뛰기




Volumn 26, Issue 3, 2010, Pages 309-321

Comparison of 3D-diffusion-prepared segmented steady-state free precession and 2D fast spin echo imaging of femoral artery atherosclerosis

Author keywords

3D dark blood MRI; Atherosclerosis; Diffusion SSFP; Femoral imaging; Peripheral artery disease; Reproducibility

Indexed keywords

ADULT; ARTICLE; ATHEROSCLEROSIS; ATHEROSCLEROTIC PLAQUE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FEMORAL ARTERY; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; INGUINAL REGION; INTERMETHOD COMPARISON; MALE; MORPHOMETRICS; NUCLEAR MAGNETIC RESONANCE IMAGING; REPRODUCIBILITY; STEADY STATE; THREE DIMENSIONAL DIFFUSION PREPARED STEADY STATE FREE PRECESSION; TWO DIMENSIONAL TURBO SPIN ECHO;

EID: 77951119472     PISSN: 15695794     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10554-009-9544-0     Document Type: Article
Times cited : (8)

References (26)
  • 1
    • 0035903242 scopus 로고    scopus 로고
    • Clinical imaging of the high-risk or vulnerable atherosclerotic plaque
    • ZA Fayad V Fuster 2001 Clinical imaging of the high-risk or vulnerable atherosclerotic plaque Circ Res 89 305 316 10.1161/hh1601.095596 1:CAS:528:DC%2BD3MXmsVert7o%3D 11509446 (Pubitemid 34132668)
    • (2001) Circulation Research , vol.89 , Issue.4 , pp. 305-316
    • Fayad, Z.A.1    Fuster, V.2
  • 3
    • 0037044418 scopus 로고    scopus 로고
    • Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: Current and potential future concepts
    • DOI 10.1161/01.CIR.0000034392.34211.FC
    • ZA Fayad V Fuster K Nikolaou C Becker 2002 Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: current and potential future concepts Circulation 106 2026 2034 10.1161/01.CIR.0000034392.34211.FC 12370230 (Pubitemid 35176312)
    • (2002) Circulation , vol.106 , Issue.15 , pp. 2026-2034
    • Fayad, Z.A.1    Fuster, V.2    Nikolaou, K.3    Becker, C.4
  • 4
    • 41949118497 scopus 로고    scopus 로고
    • Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall imaging in clinically significant atherosclerosis
    • DOI 10.1002/jmri.21282
    • N Balu B Chu TS Hatsukami C Yuan VL Yarnykh 2008 Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall imaging in clinically significant atherosclerosis J Magn Reson Imaging 27 918 924 10.1002/jmri.21282 18383253 (Pubitemid 351508111)
    • (2008) Journal of Magnetic Resonance Imaging , vol.27 , Issue.4 , pp. 918-924
    • Balu, N.1    Chu, B.2    Hatsukami, T.S.3    Yuan, C.4    Yarnykh, V.L.5
  • 7
    • 0036695901 scopus 로고    scopus 로고
    • Carotid atherosclerotic wall imaging by MRI
    • 10.1016/S1052-5149(02)00022-9 12486828
    • C Yuan ZE Miller J Cai T Hatsukami 2002 Carotid atherosclerotic wall imaging by MRI Neuroimaging Clin N Am 12 391 401 10.1016/S1052-5149(02)00022-9 12486828
    • (2002) Neuroimaging Clin N Am , vol.12 , pp. 391-401
    • Yuan, C.1    Miller, Z.E.2    Cai, J.3    Hatsukami, T.4
  • 8
    • 0035940373 scopus 로고    scopus 로고
    • In vivo accuracy of multispectral magnetic resonance imaging for identifying lipid-rich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques
    • 10.1161/hc4201.097839 1:STN:280:DC%2BD3Mrms12rtw%3D%3D 11673345
    • C Yuan LM Mitsumori MS Ferguson NL Polissar D Echelard G Ortiz R Small JW Davies WS Kerwin TS Hatsukami 2001 In vivo accuracy of multispectral magnetic resonance imaging for identifying lipid-rich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques Circulation 104 2051 2056 10.1161/hc4201.097839 1:STN:280:DC%2BD3Mrms12rtw%3D%3D 11673345
    • (2001) Circulation , vol.104 , pp. 2051-2056
    • Yuan, C.1    Mitsumori, L.M.2    Ferguson, M.S.3    Polissar, N.L.4    Echelard, D.5    Ortiz, G.6    Small, R.7    Davies, J.W.8    Kerwin, W.S.9    Hatsukami, T.S.10
  • 9
    • 0038714358 scopus 로고    scopus 로고
    • Measurement of carotid wall volume and maximum area with contrast-enhanced 3D MR imaging: Initial observations
    • DOI 10.1148/radiol.2281020484
    • S Zhang J Cai Y Luo C Han NL Polissar TS Hatsukami C Yuan 2003 Measurement of carotid wall volume and maximum area with contrast-enhanced 3D MR imaging: initial observations Radiology 228 200 205 10.1148/radiol.2281020484 12832583 (Pubitemid 36736091)
    • (2003) Radiology , vol.228 , Issue.1 , pp. 200-205
    • Zhang, S.1    Cai, J.2    Luo, Y.3    Han, C.4    Polissar, N.L.5    Hatsukami, T.S.6    Yuan, C.7
  • 10
    • 0035902442 scopus 로고    scopus 로고
    • Effects of lipid-lowering by simvastatin on human atherosclerotic lesions: A longitudinal study by high-resolution, noninvasive magnetic resonance imaging
    • 10.1161/hc4001.097191 1:CAS:528:DC%2BD3MXlslOmt7s%3D 11457739
    • R Corti ZA Fayad V Fuster SG Worthley G Helft J Chesebro M Mercuri JJ Badimon 2001 Effects of lipid-lowering by simvastatin on human atherosclerotic lesions: a longitudinal study by high-resolution, noninvasive magnetic resonance imaging Circulation 104 249 252 10.1161/hc4001.097191 1:CAS:528: DC%2BD3MXlslOmt7s%3D 11457739
    • (2001) Circulation , vol.104 , pp. 249-252
    • Corti, R.1    Fayad, Z.A.2    Fuster, V.3    Worthley, S.G.4    Helft, G.5    Chesebro, J.6    Mercuri, M.7    Badimon, J.J.8
  • 11
    • 0037016049 scopus 로고    scopus 로고
    • Lipid lowering by simvastatin induces regression of human atherosclerotic lesions: Two years' follow-up by high-resolution noninvasive magnetic resonance imaging
    • DOI 10.1161/01.CIR.0000041255.88750.F0
    • R Corti V Fuster ZA Fayad SG Worthley G Helft D Smith J Weinberger J Wentzel G Mizsei M Mercuri JJ Badimon 2002 Lipid lowering by simvastatin induces regression of human atherosclerotic lesions: two years' follow-up by high-resolution noninvasive magnetic resonance imaging Circulation 106 2884 2887 10.1161/01.CIR.0000041255.88750.F0 1:CAS:528:DC%2BD38XovVelt7k%3D 12460866 (Pubitemid 35424736)
    • (2002) Circulation , vol.106 , Issue.23 , pp. 2884-2887
    • Corti, R.1    Fuster, V.2    Fayad, Z.A.3    Worthley, S.G.4    Helft, G.5    Smith, D.6    Weinberger, J.7    Wentzel, J.8    Mizsei, G.9    Mercuri, M.10    Badimon, J.J.11
  • 12
    • 0034737974 scopus 로고    scopus 로고
    • In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: A comparison with transesophageal echocardiography
    • 1:STN:280:DC%2BD3c3pt12ktQ%3D%3D 10831525
    • ZA Fayad T Nahar JT Fallon M Goldman JG Aguinaldo JJ Badimon M Shinnar JH Chesebro V Fuster 2000 In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: a comparison with transesophageal echocardiography Circulation 101 2503 2509 1:STN:280:DC%2BD3c3pt12ktQ%3D%3D 10831525
    • (2000) Circulation , vol.101 , pp. 2503-2509
    • Fayad, Z.A.1    Nahar, T.2    Fallon, J.T.3    Goldman, M.4    Aguinaldo, J.G.5    Badimon, J.J.6    Shinnar, M.7    Chesebro, J.H.8    Fuster, V.9
  • 13
    • 4844229373 scopus 로고    scopus 로고
    • Effects of percutaneous transluminal angioplasty and endovascular brachytherapy on vascular remodeling of human femoropopliteal artery by noninvasive magnetic resonance imaging
    • DOI 10.1161/01.CIR.0000140672.70862.5B
    • R Wyttenbach A Gallino M Alerci F Mahler L Cozzi M Di Valentino JJ Badimon V Fuster R Corti 2004 Effects of percutaneous transluminal angioplasty and endovascular brachytherapy on vascular remodeling of human femoropopliteal artery by noninvasive magnetic resonance imaging Circulation 110 1156 1161 10.1161/01.CIR.0000140672.70862.5B 15326071 (Pubitemid 39319016)
    • (2004) Circulation , vol.110 , Issue.9 , pp. 1156-1161
    • Wyttenbach, R.1    Gallino, A.2    Alerci, M.3    Mahler, F.4    Cozzi, L.5    Di Valentino, M.6    Badimon, J.J.7    Fuster, V.8    Corti, R.9
  • 14
    • 33845884581 scopus 로고    scopus 로고
    • Reproducibility and reliability of atherosclerotic plaque volume measurements in peripheral arterial disease with cardiovascular magnetic resonance
    • DOI 10.1080/10976640600843330, PII NV4T7T632227G083
    • DC Isbell CH Meyer WJ Rogers FH Epstein JM DiMaria NL Harthun H Wang CM Kramer 2007 Reproducibility and reliability of atherosclerotic plaque volume measurements in peripheral arterial disease with cardiovascular magnetic resonance J Cardiovasc Magn Reson 9 71 76 10.1080/10976640600843330 17178683 (Pubitemid 46018484)
    • (2007) Journal of Cardiovascular Magnetic Resonance , vol.9 , Issue.1 , pp. 71-76
    • Isbell, D.C.1    Meyer, C.H.2    Rogers, W.J.3    Epstein, F.H.4    DiMaria, J.M.5    Harthun, N.L.6    Wang, H.7    Kramer, C.M.8
  • 15
    • 36348944620 scopus 로고    scopus 로고
    • Peripheral arterial disease assessment: Wall, perfusion, and spectroscopy
    • DOI 10.1097/rmr.0b013e31815d064c, PII 0000214220071000000006
    • CM Kramer 2007 Peripheral arterial disease assessment: wall, perfusion, and spectroscopy Top Magn Reson Imaging 18 357 369 10.1097/rmr.0b013e31815d064c 18025990 (Pubitemid 350145116)
    • (2007) Topics in Magnetic Resonance Imaging , vol.18 , Issue.5 , pp. 357-369
    • Kramer, C.M.1
  • 16
    • 0037380401 scopus 로고    scopus 로고
    • Multislice double inversion-recovery black-blood imaging with simultaneous slice reinversion
    • DOI 10.1002/jmri.10278
    • VL Yarnykh C Yuan 2003 Multislice double inversion-recovery black-blood imaging with simultaneous slice reinversion J Magn Reson Imaging 17 478 483 10.1002/jmri.10278 12655588 (Pubitemid 36396951)
    • (2003) Journal of Magnetic Resonance Imaging , vol.17 , Issue.4 , pp. 478-483
    • Yarnykh, V.L.1    Yuan, C.2
  • 17
    • 33646440711 scopus 로고    scopus 로고
    • Simultaneous outer volume and blood suppression by quadruple inversion-recovery
    • 10.1002/mrm.20880 16598725
    • VL Yarnykh C Yuan 2006 Simultaneous outer volume and blood suppression by quadruple inversion-recovery Magn Reson Med 55 1083 1092 10.1002/mrm.20880 16598725
    • (2006) Magn Reson Med , vol.55 , pp. 1083-1092
    • Yarnykh, V.L.1    Yuan, C.2
  • 19
    • 27644437673 scopus 로고    scopus 로고
    • Comparison of gated and nongated fast multislice black-blood carotid imaging using rapid extended coverage and inflow/outflow saturation techniques
    • DOI 10.1002/jmri.20428
    • V Mani VV Itskovich SH Aguiar G Mizsei JG Aguinaldo DD Samber FM Macaluso ZA Fayad 2005 Comparison of gated and non-gated fast multislice black-blood carotid imaging using rapid extended coverage and inflow/outflow saturation techniques J Magn Reson Imaging 22 628 633 10.1002/jmri.20428 16215965 (Pubitemid 41572714)
    • (2005) Journal of Magnetic Resonance Imaging , vol.22 , Issue.5 , pp. 628-633
    • Mani, V.1    Itskovich, V.V.2    Aguiar, S.H.3    Mizsei, G.4    Aguinaldo, J.G.S.5    Samber, D.D.6    Macaluso, F.M.7    Fayad, Z.A.8
  • 20
    • 2942705883 scopus 로고    scopus 로고
    • Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging
    • DOI 10.1148/radiol.2321031022
    • V Mani VV Itskovich M Szimtenings JG Aguinaldo DD Samber G Mizsei ZA Fayad 2004 Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging Radiology 232 281 288 10.1148/radiol.2321031022 15220509 (Pubitemid 38787850)
    • (2004) Radiology , vol.232 , Issue.1 , pp. 281-288
    • Mani, V.1    Itskovich, V.V.2    Szimtenings, M.3    Aguinaldo, J.G.S.4    Samber, D.D.5    Mizsei, G.6    Fayad, Z.A.7
  • 21
    • 34147195477 scopus 로고    scopus 로고
    • Three-dimensional black-blood MR imaging of carotid arteries with segmented steady-state free precession: Initial experience
    • DOI 10.1148/radiol.2431060310
    • I Koktzoglou YC Chung TJ Carroll OP Simonetti MD Morasch D Li 2007 Three-dimensional black-blood MR imaging of carotid arteries with segmented steady-state free precession: initial experience Radiology 243 220 228 10.1148/radiol.2431060310 17392255 (Pubitemid 46579714)
    • (2007) Radiology , vol.243 , Issue.1 , pp. 220-228
    • Koktzoglou, I.1    Chung, Y.-C.2    Carroll, T.J.3    Simonetti, O.P.4    Morasch, M.D.5    Li, D.6
  • 22
    • 34748912279 scopus 로고    scopus 로고
    • Dark-blood MRI of the thoracic aorta with 3D diffusion-prepared steady-state free precession: Initial clinical evaluation
    • DOI 10.2214/AJR.07.2428
    • I Koktzoglou A Kirpalani TJ Carroll D Li JC Carr 2007 Dark-blood MRI of the thoracic aorta with 3D diffusion-prepared steady-state free precession: initial clinical evaluation AJR Am J Roentgenol 189 966 972 10.2214/AJR.07.2428 17885072 (Pubitemid 47479783)
    • (2007) American Journal of Roentgenology , vol.189 , Issue.4 , pp. 966-972
    • Koktzoglou, I.1    Kirpalani, A.2    Carroll, T.J.3    Li, D.4    Carr, J.C.5
  • 23
    • 33845904636 scopus 로고    scopus 로고
    • Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls
    • DOI 10.1080/10976640600843413, PII X62575X231G02776
    • I Koktzoglou D Li 2007 Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls J Cardiovasc Magn Reson 9 33 42 10.1080/10976640600843413 17178678 (Pubitemid 46018481)
    • (2007) Journal of Cardiovascular Magnetic Resonance , vol.9 , Issue.1 , pp. 33-42
    • Koktzoglou, I.1    Li, D.2
  • 24
    • 0000394113 scopus 로고
    • Matching to remove bias in observational studies
    • 10.2307/2529684
    • DB Rubin 1973 Matching to remove bias in observational studies Biometrics 29 159 183 10.2307/2529684
    • (1973) Biometrics , vol.29 , pp. 159-183
    • Rubin, D.B.1
  • 25
    • 34347375489 scopus 로고    scopus 로고
    • Agreement between methods of measurement with multiple observations per individual
    • DOI 10.1080/10543400701329422, PII 780214319
    • JM Bland DG Altman 2007 Agreement between methods of measurement with multiple observations per individual J Biopharm Stat 17 571 582 10.1080/10543400701329422 17613642 (Pubitemid 47027010)
    • (2007) Journal of Biopharmaceutical Statistics , vol.17 , Issue.4 , pp. 571-582
    • Bland, J.M.1    Altman, D.G.2
  • 26
    • 70350714054 scopus 로고    scopus 로고
    • Three-dimensional T2-weighted MRI of the human femoral arterial vessel wall at 3.0 Tesla
    • 10.1097/RLI.0b013e3181b4c218 19692844
    • Z Zhang Z Fan TJ Carroll Y Chung P Weale R Jerecic D Li 2009 Three-dimensional T2-weighted MRI of the human femoral arterial vessel wall at 3.0 Tesla Invest Radiol 44 619 626 10.1097/RLI.0b013e3181b4c218 19692844
    • (2009) Invest Radiol , vol.44 , pp. 619-626
    • Zhang, Z.1    Fan, Z.2    Carroll, T.J.3    Chung, Y.4    Weale, P.5    Jerecic, R.6    Li, D.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.