메뉴 건너뛰기




Volumn 19, Issue 3, 2010, Pages 376-383

Scoliosis in Duchenne's muscular dystrophy: A changing trend in surgical management : Aistorical surgical outcome study comparing sublaminar, hybrid and pedicle screw instrumentation systems

Author keywords

Duchenne's muscular dystrophy; Hybrid instrumentation; Pedicle screw system; Scoliosis; Sublaminar instrumentation

Indexed keywords

ADOLESCENT; ARTICLE; BLEEDING; CHILD; CLINICAL ARTICLE; CONTROLLED STUDY; DUCHENNE MUSCULAR DYSTROPHY; FOLLOW UP; HUMAN; INTERMETHOD COMPARISON; OPERATION DURATION; ORTHOPEDIC EQUIPMENT; PEDICLE SCREW; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; PRIORITY JOURNAL; PROSTHESIS FAILURE; SCHOOL CHILD; SCOLIOSIS; SPINE FUSION; SUBLAMINAR AND PEDICLE SCREW SYSTEM; SUBLAMINAR INSTRUMENTATION SYSTEM; WOUND INFECTION;

EID: 77951108697     PISSN: 09406719     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00586-009-1163-x     Document Type: Article
Times cited : (35)

References (29)
  • 2
    • 0031840376 scopus 로고    scopus 로고
    • Surgery of the spine in Duchenne's muscular dystrophy
    • 1:STN:280:DyaK1cvkvVWksg%3D%3D 9775044
    • H Chataigner V Grelet M Onimus 1998 Surgery of the spine in Duchenne's muscular dystrophy Rev Chir Orthop Reparatrice Appar Mot 84 3 224 230 1:STN:280:DyaK1cvkvVWksg%3D%3D 9775044
    • (1998) Rev Chir Orthop Reparatrice Appar Mot , vol.84 , Issue.3 , pp. 224-230
    • Chataigner, H.1    Grelet, V.2    Onimus, M.3
  • 3
    • 4344698908 scopus 로고    scopus 로고
    • Surgical treatment of spinal deformities in Duchenne muscular dystrophy: A long term follow-up study
    • 10.1007/s00586-002-0515-6 1:STN:280:DC%2BD2czovVSjtw%3D%3D 15108098
    • S Cervellati N Bettini M Moscato A Gusella E Dema R Maresi 2004 Surgical treatment of spinal deformities in Duchenne muscular dystrophy: a long term follow-up study Eur Spine J 13 5 441 448 10.1007/s00586-002-0515-6 1:STN:280:DC%2BD2czovVSjtw%3D%3D 15108098
    • (2004) Eur Spine J , vol.13 , Issue.5 , pp. 441-448
    • Cervellati, S.1    Bettini, N.2    Moscato, M.3    Gusella, A.4    Dema, E.5    Maresi, R.6
  • 4
    • 0001591197 scopus 로고    scopus 로고
    • Flexible and semi-early vertebral instrumentation in surgical treatment of Duchenne muscular dystrophy scoliosis
    • 10.1007/BF00573326
    • LE Gayet G Duport P Pries 1999 Flexible and semi-early vertebral instrumentation in surgical treatment of Duchenne muscular dystrophy scoliosis Eur J Orthop Surg Traumatol 9 4 223 231 10.1007/BF00573326
    • (1999) Eur J Orthop Surg Traumatol , vol.9 , Issue.4 , pp. 223-231
    • Gayet, L.E.1    Duport, G.2    Pries, P.3
  • 5
    • 0142058935 scopus 로고    scopus 로고
    • The treatment of neuromuscular scoliosis
    • DOI 10.1016/S0268-0890(03)00002-1
    • KS Mehta MJ Gibson 2003 The treatment of neuromuscular scoliosis Curr Orthop 17 4 313 321 10.1016/S0268-0890(03)00002-1 (Pubitemid 37295097)
    • (2003) Current Orthopaedics , vol.17 , Issue.4 , pp. 313-321
    • Mehta, J.S.1    Gibson, M.J.2
  • 6
    • 0021345774 scopus 로고
    • The treatment of scoliosis in Duchenne muscular dystrophy
    • Y Rideau B Glorion A Delaubier O Tarlé J Bach 1984 The treatment of scoliosis in Duchenne muscular dystrophy Muscle Nerve 7 4 281 286 10.1002/mus.880070405 1:STN:280:DyaL2c3hvFGgug%3D%3D 6727912 (Pubitemid 14142408)
    • (1984) Muscle and Nerve , vol.7 , Issue.4 , pp. 281-286
    • Rideau, Y.1    Glorion, B.2    Delaubier, A.3
  • 7
    • 0021627541 scopus 로고
    • Advantage of early spinal stabilization and fusion in patients with Duchenne muscular dystrophy
    • 1:STN:280:DyaL2M%2FjtV2ruw%3D%3D 6490869
    • MD Sussman 1984 Advantage of early spinal stabilization and fusion in patients with Duchenne muscular dystrophy J Pediatr Orthop 4 532 537 1:STN:280:DyaL2M%2FjtV2ruw%3D%3D 6490869
    • (1984) J Pediatr Orthop , vol.4 , pp. 532-537
    • Sussman, M.D.1
  • 8
    • 0031451988 scopus 로고    scopus 로고
    • Characteristics in the treatment of scoliosis in muscular diseases
    • 10.1055/s-2008-1039563 1:STN:280:DyaK2szgvF2jtA%3D%3D 9214180
    • R Forst J Forst KD Heller K Hengstler 1997 Characteristics in the treatment of scoliosis in muscular diseases Z Orthop Ihre Grenzgeb 135 2 95 105 10.1055/s-2008-1039563 1:STN:280:DyaK2szgvF2jtA%3D%3D 9214180
    • (1997) Z Orthop Ihre Grenzgeb , vol.135 , Issue.2 , pp. 95-105
    • Forst, R.1    Forst, J.2    Heller, K.D.3    Hengstler, K.4
  • 9
    • 0027945683 scopus 로고
    • Multi-segmental fusion of scoliosis in Duchenne's muscular dystrophy
    • 10.1055/s-2008-1039840 1:STN:280:DyaK2M%2Fns1KrtQ%3D%3D 7985396
    • C Hopf R Forst J Forst P Eysel B Reitter 1994 Multi-segmental fusion of scoliosis in Duchenne's muscular dystrophy Z Orthop Ihre Grenzgeb 132 5 377 382 10.1055/s-2008-1039840 1:STN:280:DyaK2M%2Fns1KrtQ%3D%3D 7985396
    • (1994) Z Orthop Ihre Grenzgeb , vol.132 , Issue.5 , pp. 377-382
    • Hopf, C.1    Forst, R.2    Forst, J.3    Eysel, P.4    Reitter, B.5
  • 10
    • 0016609338 scopus 로고
    • Evolution of treatment of paralytic scoliosis in Rancho Los Amigos hospital
    • 1:STN:280:DyaE2M%2FpsFOjsw%3D%3D 1112847
    • C Bonnett JC Brown J Perry, et al.. 1975 Evolution of treatment of paralytic scoliosis in Rancho Los Amigos hospital J Bone Joint Surg Am 57 206 215 1:STN:280:DyaE2M%2FpsFOjsw%3D%3D 1112847
    • (1975) J Bone Joint Surg Am , vol.57 , pp. 206-215
    • Bonnett, C.1    Brown, J.C.2    Perry, J.3
  • 11
    • 73649165677 scopus 로고
    • Treatment of scoliosis correction and internal fixation by spine instrumentation
    • 14036052
    • PR Harrington 1962 Treatment of scoliosis correction and internal fixation by spine instrumentation J Bone Joint Surg Am 44 591 634 14036052
    • (1962) J Bone Joint Surg Am , vol.44 , pp. 591-634
    • Harrington, P.R.1
  • 12
    • 0020036461 scopus 로고
    • Segmental spinal instrumentation
    • 7067252
    • ER Luque 1982 Segmental spinal instrumentation Clin Orthop Relat Res 163 192 198 7067252
    • (1982) Clin Orthop Relat Res , vol.163 , pp. 192-198
    • Luque, E.R.1
  • 13
    • 0024430090 scopus 로고
    • Segmental spinal instrumentation using short closed wire loops
    • 2791399
    • H Mehdian S Eisenstein 1989 Segmental spinal instrumentation using short closed wire loops Clin Orthop Relat Res 247 90 96 2791399
    • (1989) Clin Orthop Relat Res , vol.247 , pp. 90-96
    • Mehdian, H.1    Eisenstein, S.2
  • 14
    • 0024435290 scopus 로고
    • Spinal stabilization for scoliosis in Duchenne muscular dystrophy: Experience with various sublaminar instrumentation system
    • H Mehdian N Shimizu V Draycott 1989 Spinal stabilization for scoliosis in Duchenne muscular dystrophy: experience with various sublaminar instrumentation system Neuro-Orthopedics 7 74 82
    • (1989) Neuro-Orthopedics , vol.7 , pp. 74-82
    • Mehdian, H.1    Shimizu, N.2    Draycott, V.3
  • 15
    • 0027423108 scopus 로고
    • Spinal fusion in Duchenne muscular dystrophy: Fixation and fusion to the sacropelvis?
    • 1:STN:280:DyaK2c%2FmsVyrsg%3D%3D 8245201
    • SJ Mubarak WD Morin J Leach 1993 Spinal fusion in Duchenne muscular dystrophy: fixation and fusion to the sacropelvis? J Pediatr Orthop 13 752 757 1:STN:280:DyaK2c%2FmsVyrsg%3D%3D 8245201
    • (1993) J Pediatr Orthop , vol.13 , pp. 752-757
    • Mubarak, S.J.1    Morin, W.D.2    Leach, J.3
  • 16
    • 0032885828 scopus 로고    scopus 로고
    • Pelvic obliquity after fusion of the spine in Duchenne muscular dystrophy
    • DOI 10.1302/0301-620X.81B5.9383
    • BA Alman HK Kim 1999 Pelvic obliquity after fusion of the spine in Duchenne muscular dystrophy J Bone Joint Surg Br 81 821 824 10.1302/0301-620X. 81B5.9383 1:STN:280:DyaK1MvlvVChtA%3D%3D 10530843 (Pubitemid 29438357)
    • (1999) Journal of Bone and Joint Surgery - Series B , vol.81 , Issue.5 , pp. 821-824
    • Alman, B.A.1    Kim, H.K.W.2
  • 17
    • 0037106201 scopus 로고    scopus 로고
    • Pelvic or lumbar fixation for the surgical management of scoliosis in Duchenne muscular dystrophy
    • 10.1097/00007632-200209150-00020 12634572
    • DK Sengupta SH Mehdian JR McConnell SM Eisenstein JK Webb 2002 Pelvic or lumbar fixation for the surgical management of scoliosis in Duchenne muscular dystrophy Spine 27 18 2072 2079 10.1097/00007632-200209150-00020 12634572
    • (2002) Spine , vol.27 , Issue.18 , pp. 2072-2079
    • Sengupta, D.K.1    Mehdian, S.H.2    McConnell, J.R.3    Eisenstein, S.M.4    Webb, J.K.5
  • 19
    • 0028822726 scopus 로고
    • Lung function in Duchenne muscular dystrophy
    • 10.1007/BF00301031 1:STN:280:DyaK287ivVCjtg%3D%3D 8581525
    • CS Galasko JB Williamson CM Delaney 1995 Lung function in Duchenne muscular dystrophy Eur Spine J 4 5 263 267 10.1007/BF00301031 1:STN:280:DyaK287ivVCjtg%3D%3D 8581525
    • (1995) Eur Spine J , vol.4 , Issue.5 , pp. 263-267
    • Galasko, C.S.1    Williamson, J.B.2    Delaney, C.M.3
  • 20
    • 0028847290 scopus 로고
    • Effect of spinal surgery on lung function in Duchenne muscular dystrophy
    • 10.1136/thx.50.11.1173 1:STN:280:DyaK287kvFehsw%3D%3D 8553273
    • JD Kennedy AJ Staples PD Brook, et al. 1995 Effect of spinal surgery on lung function in Duchenne muscular dystrophy Thorax 50 11 1173 1178 10.1136/thx.50.11.1173 1:STN:280:DyaK287kvFehsw%3D%3D 8553273
    • (1995) Thorax , vol.50 , Issue.11 , pp. 1173-1178
    • Kennedy, J.D.1    Staples, A.J.2    Brook, P.D.3
  • 21
    • 0023638607 scopus 로고
    • Segmental spinal instrumentation with sublaminar wires. A critical appraisal
    • 1:STN:280:DyaL2s3ltVOgtA%3D%3D 3597498
    • WA Herndon JA Sullivan DA Yngve RH Gross G Dreher 1987 Segmental spinal instrumentation with sublaminar wires. A critical appraisal J Bone Joint Surg Am 69 851 859 1:STN:280:DyaL2s3ltVOgtA%3D%3D 3597498
    • (1987) J Bone Joint Surg Am , vol.69 , pp. 851-859
    • Herndon, W.A.1    Sullivan, J.A.2    Yngve, D.A.3    Gross, R.H.4    Dreher, G.5
  • 22
    • 0023722037 scopus 로고
    • Cotrel-Dubousset instrumentation in adults. A preliminary report
    • 10.1097/00007632-198805000-00014 1:STN:280:DyaL1M%2FksVagtg%3D%3D 3187697
    • KR Gurr PC McAfee 1988 Cotrel-Dubousset instrumentation in adults. A preliminary report Spine 13 5 510 520 10.1097/00007632-198805000-00014 1:STN:280:DyaL1M%2FksVagtg%3D%3D 3187697
    • (1988) Spine , vol.13 , Issue.5 , pp. 510-520
    • Gurr, K.R.1    McAfee, P.C.2
  • 23
    • 0038205965 scopus 로고    scopus 로고
    • In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables
    • 12859069
    • PW Hitchon MD Brenton AG Black, et al. 2003 In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables J Neurosurg 99 1 Suppl 104 109 12859069
    • (2003) J Neurosurg , vol.99 , Issue.SUPPL1 , pp. 104-109
    • Hitchon, P.W.1    Brenton, M.D.2    Black, A.G.3
  • 24
    • 33645917710 scopus 로고    scopus 로고
    • Thoracic pedicle screw fixation for spinal deformity
    • 10.3171/foc.2003.14.1.8 15766224
    • MK Rosner DW Polly TR Kuklo SL Ondra 2003 Thoracic pedicle screw fixation for spinal deformity Neurosurg Focus 14 1 e7 10.3171/foc.2003.14.1.8 15766224
    • (2003) Neurosurg Focus , vol.14 , Issue.1 , pp. 7
    • Rosner, M.K.1    Polly, D.W.2    Kuklo, T.R.3    Ondra, S.L.4
  • 25
    • 32244435001 scopus 로고    scopus 로고
    • Comparative analysis of pedicle screw versus hybrid instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis
    • DOI 10.1097/01.brs.0000197865.20803.d4
    • YJ Kim LG Lenke J Kim, et al. 2006 Comparative analysis of pedicle screw versus hybrid instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis Spine 31 3 291 298 10.1097/01.brs.0000197865.20803.d4 16449901 (Pubitemid 43214769)
    • (2006) Spine , vol.31 , Issue.3 , pp. 291-298
    • Kim, Y.J.1    Lenke, L.G.2    Kim, J.3    Bridwell, K.H.4    Cho, S.K.5    Cheh, G.6    Sides, B.7
  • 26
    • 0035884966 scopus 로고    scopus 로고
    • Thoracic pedicle screw fixation in spinal deformities: Are they really safe?
    • DOI 10.1097/00007632-200109150-00022
    • SI Suk WJ Kim SM Lee JH Kim ER Chung 2001 Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine 26 18 2049 2057 10.1097/00007632-200109150-00022 1:STN:280:DC%2BD3MvpvVGntQ%3D%3D 11547207 (Pubitemid 32852102)
    • (2001) Spine , vol.26 , Issue.18 , pp. 2049-2057
    • Suk, S.-I.1    Kim, W.-J.2    Lee, S.-M.3    Kim, J.-H.4    Chung, E.-R.5
  • 27
    • 77951114732 scopus 로고    scopus 로고
    • Biomechanics in posterior spinal instrumentation in biomechanics and biomaterials, Chapter 43
    • D.G. Poitout (eds). Springer Berlin
    • Suk SI, Kim WJ (2004) Biomechanics in posterior spinal instrumentation in biomechanics and biomaterials, Chapter 43. In: Poitout DG (ed) Orthopaedics. Springer, Berlin, pp 462-491
    • (2004) Orthopaedics , pp. 462-491
    • Suk, S.I.1    Kim, W.J.2
  • 28
    • 0344826538 scopus 로고    scopus 로고
    • Blood loss during posterior spinal fusion surgery in patients with neuromuscular disease: Is there an increased risk?
    • DOI 10.1046/j.1460-9592.2003.01171.x
    • A Edler DJ Murray RB Forbes 2003 Blood loss during posterior spinal fusion surgery in patients with neuromuscular disease: is there an increased risk? Paediatr Anesth 13 9 818 10.1046/j.1460-9592.2003.01171.x (Pubitemid 37475883)
    • (2003) Paediatric Anaesthesia , vol.13 , Issue.9 , pp. 818-822
    • Edler, A.1    Murray, D.J.2    Forbes, R.B.3
  • 29
    • 0035104081 scopus 로고    scopus 로고
    • The treatment of scoliosis in muscular dystrophy using modified Luque and Harrington-Luque instrumentation
    • 10.1302/0301-620X.83B1.10029
    • G Bentley F Haddad TM Bull D Seingry 2001 The treatment of scoliosis in muscular dystrophy using modified Luque and Harrington-Luque instrumentation J Bone Joint Surg Br 83-B 22 28 10.1302/0301-620X.83B1.10029
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 22-28
    • Bentley, G.1    Haddad, F.2    Bull, T.M.3    Seingry, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.