메뉴 건너뛰기




Volumn 40, Issue 4, 2010, Pages 518-527

Neonatal cardiac imaging

Author keywords

Cardiac; CT; Gadolinium; Imaging; Indications; MRI; Neonate; Radiography; Technique

Indexed keywords

GADODIAMIDE; GADOLINIUM; GADOLINIUM PENTETATE; IODINATED CONTRAST MEDIUM;

EID: 77951004892     PISSN: 03010449     EISSN: 14321998     Source Type: Journal    
DOI: 10.1007/s00247-010-1549-2     Document Type: Review
Times cited : (34)

References (20)
  • 1
    • 0021667401 scopus 로고
    • The segmental approach clarified
    • Van Praagh R (1984) The segmental approach clarified. Cardiovasc Intervent Radiol 7(6):320-325
    • (1984) Cardiovasc Intervent Radiol , vol.7 , Issue.6 , pp. 320-325
    • Van Praagh, R.1
  • 2
    • 29344460281 scopus 로고    scopus 로고
    • Chest radiography and the evaluation of the neonate for congenital heart disease
    • DOI 10.1007/s00246-005-8649-z
    • Fonseca B, Chang RK, Senac M et al (2005) Chest radiography and the evaluation of the neonate for congenital heart disease. Pediatr Cardiol 26:367-372 (Pubitemid 43004579)
    • (2005) Pediatric Cardiology , vol.26 , Issue.4 , pp. 367-372
    • Fonseca, B.1    Chang, R.-K.2    Senac, M.3    Knight, G.4    Sklansky, M.S.5
  • 3
    • 17644445000 scopus 로고    scopus 로고
    • Chest roentgenogram in the evaluation of heart defects in asymptomatic infants and children with a cardiac murmur: reproducibility and accuracy
    • Birkebaek NH, Hansen LK, Elle B et al (1999) Chest roentgenogram in the evaluation of heart defects in asymptomatic infants and children with a cardiac murmur: reproducibility and accuracy. Pediatrics 103(2):E15
    • (1999) Pediatrics , vol.103 , Issue.2
    • Birkebaek, N.H.1    Hansen, L.K.2    Elle, B.3
  • 5
    • 0036693650 scopus 로고    scopus 로고
    • Diagnostic value of the chest radiograph in asymptomatic neonates with a cardiac murmur
    • Oeppen RS, Fairhurst JJ, Argent JD (2002) Diagnostic value of the chest radiograph in asymptomatic neonates with a cardiac murmur. Clin Radiol 57:736-740
    • (2002) Clin Radiol , vol.57 , pp. 736-740
    • Oeppen, R.S.1    Fairhurst, J.J.2    Argent, J.D.3
  • 7
    • 57949083852 scopus 로고    scopus 로고
    • Borderline hypoplasia of the left ventricle in neonates: Insights for decisionmaking from functional assessment with magnetic resonance imaging
    • Grosse-Wortmann L, Yun TJ, Al-Radi OK et al (2008) Borderline hypoplasia of the left ventricle in neonates: insights for decisionmaking from functional assessment with magnetic resonance imaging. J Thorac Cardiovasc Surg 136:1429-1436
    • (2008) J Thorac Cardiovasc Surg , vol.136 , pp. 1429-1436
    • Grosse-Wortmann, L.1    Yun, T.J.2    Al-Radi, O.K.3
  • 8
    • 33847009928 scopus 로고    scopus 로고
    • Cardiovascular MR imaging in neonates and infants with congenital heart disease
    • Kellenberger CJ, Yoo SJ, Büchel ER (2007) Cardiovascular MR imaging in neonates and infants with congenital heart disease. Radiographics 27(1):5-18
    • (2007) Radiographics , vol.27 , Issue.1 , pp. 5-18
    • Kellenberger, C.J.1    Yoo, S.J.2    Büchel, E.R.3
  • 9
    • 61549094947 scopus 로고    scopus 로고
    • Magnetic resonance imaging in congenital heart disease: What to do with what we see and don't see?
    • McQuillen PS (2009) Magnetic resonance imaging in congenital heart disease: what to do with what we see and don't see? Circulation 119:660-662
    • (2009) Circulation , vol.119 , pp. 660-662
    • McQuillen, P.S.1
  • 10
    • 0036176161 scopus 로고    scopus 로고
    • K/DOQ1 clinical practice guidelines for chronic kidney disease: Evaluation, classification and stratification
    • National Kidney Foundation
    • National Kidney Foundation (2002) K/DOQ1 clinical practice guidelines for chronic kidney disease: evaluation, classification and stratification. Am J Kidney Dis 39(Suppl 1):S1-266
    • (2002) Am J Kidney Dis , vol.39 , Issue.SUPPL. 1
  • 11
    • 41949086864 scopus 로고    scopus 로고
    • European Society of Urogenital Radiology (ESUR) guideline: Gadolinium-based contrast media and nephrogenic systemic fibrosis
    • Thomsen HS (2007) European Society of Urogenital Radiology (ESUR) guideline: gadolinium-based contrast media and nephrogenic systemic fibrosis. Eur Radiol 17(10):2692-2696
    • (2007) Eur Radiol , vol.17 , Issue.10 , pp. 2692-2696
    • Thomsen, H.S.1
  • 12
    • 55749114067 scopus 로고    scopus 로고
    • Gadolinium and nephrogenic systemic fibrosis - What to consider for pediatric MR imaging
    • Pediatric NSF statement. In: Fotter R (ed), 2nd edn. Springer, Berlin
    • Riccabona M, Dacher JN, Olsen OE et al (2007) Gadolinium and nephrogenic systemic fibrosis - what to consider for pediatric MR imaging. Pediatric NSF statement. In: Fotter R (ed) Pediatric uroradiology, 2nd edn. Springer, Berlin, pp 516- 517
    • (2007) Pediatric Uroradiology , pp. 516-517
    • Riccabona, M.1    Dacher, J.N.2    Olsen, O.E.3
  • 13
    • 0033983192 scopus 로고    scopus 로고
    • Safety and efficacy of omniscan (Gadodiamide injection) at 0.1 mmol/kg for MRI in infants younger than 6 months of age: Phase III open multicenter study
    • DOI 10.1097/00004424-200002000-00008
    • Martí-Bonmatí L, Vega T, Benito C et al (2000) Safety and efficacy of Omniscan (gadodiamide injection) at 0.1 mmol/kg for MRI in infants younger than 6 months of age: phase III open multicenter study. Invest Radiol 35(2):141-147 (Pubitemid 30078275)
    • (2000) Investigative Radiology , vol.35 , Issue.2 , pp. 141-147
    • Marti-Bonmati, L.1    Vega, T.2    Benito, C.3    Munoz, A.4    Niewel, M.5    Menor, F.6    Meurer, K.7    Encina, J.L.8
  • 14
    • 3042558084 scopus 로고    scopus 로고
    • Clinical role, accuracy, and technical aspects of cardiovascular magnetic resonance imaging in infants
    • DOI 10.1016/j.amjcard.2004.03.033, PII S0002914904004473
    • Tsai-Goodman B, Geva T, Odegard KC et al (2004) Clinical role, accuracy, and technical aspects of cardiovascular magnetic resonance imaging in infants. Am J Cardiol 94(1):69-74 (Pubitemid 38813457)
    • (2004) American Journal of Cardiology , vol.94 , Issue.1 , pp. 69-74
    • Tsai-Goodman, B.1    Geva, T.2    Odegard, K.C.3    Sena, L.M.4    Powell, A.J.5
  • 15
    • 34547702599 scopus 로고    scopus 로고
    • Usefulness of Magnetic Resonance Angiography in the Evaluation of Complex Congenital Heart Disease in Newborns and Infants
    • DOI 10.1016/j.amjcard.2007.03.090, PII S0002914907009654
    • Prakash A, Torres AJ, Printz BF et al (2007) Usefulness of magnetic resonance angiography in the evaluation of complex congenital heart disease in newborns and infants. Am J Cardiol 100(4):715-721 (Pubitemid 47223151)
    • (2007) American Journal of Cardiology , vol.100 , Issue.4 , pp. 715-721
    • Prakash, A.1    Torres, A.J.2    Printz, B.F.3    Prince, M.R.4    Nielsen, J.C.5
  • 16
    • 33750055753 scopus 로고    scopus 로고
    • Clinical feasibility of free-breathing, gadolinium-enhanced magnetic resonance angiography for assessing extracardiac thoracic vascular abnormalities in young children with congenital heart diseases
    • Ko SF, Liang CD, Huang CC et al (2006) Clinical feasibility of free-breathing, gadolinium-enhanced magnetic resonance angiography for assessing extracardiac thoracic vascular abnormalities in young children with congenital heart diseases. J Thorac Cardiovasc Surg 132(5):1092-1098
    • (2006) J Thorac Cardiovasc Surg , vol.132 , Issue.5 , pp. 1092-1098
    • Ko, S.F.1    Liang, C.D.2    Huang, C.C.3
  • 18
    • 63349096396 scopus 로고    scopus 로고
    • Pediatric cardiac CT
    • In: Lucaya J, Strife JL (eds), 2nd edn. Springer, Berlin
    • Sena L, Krishnamurthy R, Chung T (2007) Pediatric cardiac CT. In: Lucaya J, Strife JL (eds) Pediatric chest imaging, 2nd edn. Springer, Berlin
    • (2007) Pediatric Chest Imaging
    • Sena, L.1    Krishnamurthy, R.2    Chung, T.3
  • 19
    • 40849133825 scopus 로고    scopus 로고
    • Neonatal cardiac multidetector row CT: Why and how we do it
    • Tsai IC, Chen MC, Jan SL et al (2008) Neonatal cardiac multidetector row CT: why and how we do it. Pediatr Radiol 38 (4):438-451
    • (2008) Pediatr Radiol , vol.38 , Issue.4 , pp. 438-451
    • Tsai, I.C.1    Chen, M.C.2    Jan, S.L.3
  • 20
    • 33845548037 scopus 로고    scopus 로고
    • Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: Initial experiences in technical and clinical feasibility
    • DOI 10.1007/s00247-006-0315-y
    • Lee T, Tsai IC, Fu YC et al (2006) Using multidetector row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility. Pediatr Radiol 36(12):1273-1282 (Pubitemid 44920864)
    • (2006) Pediatric Radiology , vol.36 , Issue.12 , pp. 1273-1282
    • Lee, T.1    Tsai, I.-C.2    Fu, Y.-C.3    Jan, S.-L.4    Wang, C.-C.5    Chang, Y.6    Chen, M.-C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.