메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1804-1807

Environmental stress: Approximate entropy approach revisited

Author keywords

[No Author keywords available]

Indexed keywords

RATS;

EID: 77951004235     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5332762     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 1
    • 0026015905 scopus 로고
    • Approximate entropy as a measure of system complexity
    • S.M. Pincus, "Approximate entropy as a measure of system complexity", Proc Natl Acad Sci USA;Vol. 88, 1991,pp 2297-2301,
    • (1991) Proc Natl Acad Sci USA , vol.88 , pp. 2297-2301
    • Pincus, S.M.1
  • 2
    • 0028355806 scopus 로고
    • Physiological time-series analysis: What does regularity quantify?
    • A.L. Goldberger, S.M. Pincus, "Physiological time-series analysis: What does regularity quantify?" Am J Physiol(Heart Circ Physiol), Vol.266, 1994, pp H1643-H1656.
    • (1994) Am J Physiol(Heart Circ Physiol) , vol.266
    • Goldberger, A.L.1    Pincus, S.M.2
  • 3
    • 0033949457 scopus 로고    scopus 로고
    • Physiological time-series analysis using approximate entropy and sample entropy
    • J.S. Richman, J.R. Moorman, "Physiological time-series analysis using approximate entropy and sample entropy" Am J Physiol Heart Circ Physiol Vol.278(6), 2000, ppH2039-H2049.
    • (2000) Am J Physiol Heart Circ Physiol , vol.278 , Issue.6
    • Richman, J.S.1    Moorman, J.R.2
  • 5
    • 47649088553 scopus 로고    scopus 로고
    • Automatic selection of the threshold value r for approximate entropy
    • Aug.
    • S.Lu, X.Chen, J.K.Kanters, I.C.Solomon and K.H.Chon, "Automatic selection of the threshold value r for approximate entropy", IEEE Trans. Biomed. Eng. Vo55., no.8, Aug.2008.,pp.1966-1972
    • (2008) IEEE Trans. Biomed. Eng. , vol.55 , Issue.8 , pp. 1966-1972
    • Lu, S.1    Chen, X.2    Kanters, J.K.3    Solomon, I.C.4    Chon, K.H.5
  • 7
    • 62249091785 scopus 로고    scopus 로고
    • How the Threshold "R" Influences Approximate Entropy Analysis of Heart-Rate Variability
    • P Castiglioni, M Di Rienzo, "How the Threshold "R" Influences Approximate Entropy Analysis of Heart-Rate Variability", Computers in cardiology, vol.35, 2008, pp.561-564
    • (2008) Computers in Cardiology , vol.35 , pp. 561-564
    • Castiglioni, P.1    Di Rienzo, M.2
  • 8
    • 54149104033 scopus 로고    scopus 로고
    • The effect of time delay on Approximate and Sample entropy calculations
    • F. Kaffashi, R.Foglyano, C.G.Wilson and K.Loparo, "The effect of time delay on Approximate and Sample entropy calculations", Physica D, vol 237, 2008, pp.3069-3074;
    • (2008) Physica D , vol.237 , pp. 3069-3074
    • Kaffashi, F.1    Foglyano, R.2    Wilson, C.G.3    Loparo, K.4
  • 9
    • 0036157955 scopus 로고    scopus 로고
    • An advanced detrending approach with application to HRV analysis
    • M. P. Tarvainen, P. O. Ranta-aho, and P. A. Karjalainen, "An advanced detrending approach with application to HRV analysis," IEEE Trans. Biomed. Eng. vol 42., no.2., 2002, pp. 172-174.
    • (2002) IEEE Trans. Biomed. Eng. , vol.42 , Issue.2 , pp. 172-174
    • Tarvainen, M.P.1    Ranta-aho, P.O.2    Karjalainen, P.A.3
  • 10
    • 0036656226 scopus 로고    scopus 로고
    • Dimensional Analysis of HRV in Hypertrophic Cardiomyopathy Patientes
    • July
    • R. Karvajal et al.: "Dimensional Analysis of HRV in Hypertrophic Cardiomyopathy Patientes", IEEE Engineering in Medicine and Biology, 21(4), pp 71-78, July 2002.
    • (2002) IEEE Engineering in Medicine and Biology , vol.21 , Issue.4 , pp. 71-78
    • Karvajal, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.