메뉴 건너뛰기




Volumn , Issue , 2009, Pages 65-68

Accurate reconstruction of brain activity and functional connectivity from noisy MEG data

Author keywords

[No Author keywords available]

Indexed keywords

BAYESIAN NETWORKS; BRAIN MAPPING; MAGNETOENCEPHALOGRAPHY; NEUROPHYSIOLOGY;

EID: 77951000736     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5335005     Document Type: Conference Paper
Times cited : (5)

References (8)
  • 1
    • 34548413755 scopus 로고    scopus 로고
    • A probabilistic algorithm for robust interference suppression in bioelectromagnetic sensor data
    • Sept.
    • S.S. Nagarajan, et al., "A probabilistic algorithm for robust interference suppression in bioelectromagnetic sensor data," Stat Med. vol.26, no.21, pp. 3886-910 Sept. 2007.
    • (2007) Stat Med , vol.26 , Issue.21 , pp. 3886-3910
    • Nagarajan, S.S.1
  • 2
    • 4444355027 scopus 로고    scopus 로고
    • Identifying true brain interaction from EEG data using the imaginary part of coherency
    • G. Nolte, et al. Identifying true brain interaction from EEG data using the imaginary part of coherency," Clinical Neurophysiology. vol. 100, no. 10, pp. 2292-2307, 2004.
    • (2004) Clinical Neurophysiology , vol.100 , Issue.10 , pp. 2292-2307
    • Nolte, G.1
  • 3
    • 0036454342 scopus 로고    scopus 로고
    • Standardized low resolution brain electromagnetic tomography (sloreta): Technical details
    • R.D. Pascual-Marqui, "Standardized low resolution brain electromagnetic tomography (sloreta): Technical details," Methods and Findings in Experimental and Clinical Pharmacology, vol. 24, no. Suppl D, pp. 5-12, 2002.
    • (2002) Methods and Findings in Experimental and Clinical Pharmacology , vol.24 , Issue.SUPPL. D , pp. 5-12
    • Pascual-Marqui, R.D.1
  • 5
    • 0029033726 scopus 로고
    • Selective minimum-norm solution of the biomagnetic inverse problem
    • K. Matsuura, et al., "Selective minimum-norm solution of the biomagnetic inverse problem," IEEE Trans. Biomed. Eng. vol.42, pp. 608-615, 1995.
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , pp. 608-615
    • Matsuura, K.1
  • 6
    • 57649220812 scopus 로고    scopus 로고
    • A Unified Bayesian Framework for MEG/EEG Source Imaging
    • D. Wipf, et al., "A Unified Bayesian Framework for MEG/EEG Source Imaging," Neuroimage vol.44, no.3,pp. 947-966, 2009.
    • (2009) Neuroimage , vol.44 , Issue.3 , pp. 947-966
    • Wipf, D.1
  • 7
    • 57649152931 scopus 로고    scopus 로고
    • Estimating the Location and Orientation of Complex, Correlated Neural Activity using MEG
    • D. Wipf, et al., "Estimating the Location and Orientation of Complex, Correlated Neural Activity using MEG," Advances in Neural Information Processing Systems 21 2009.
    • (2009) Advances in Neural Information Processing Systems , vol.21
    • Wipf, D.1
  • 8
    • 70349962981 scopus 로고    scopus 로고
    • Robust Bayesian Estimation of the Location, Orientation, and Timecourse of Multiple Correlated Neural Sources Using MEG
    • In Revision
    • D. Wipf, et al., "Robust Bayesian Estimation of the Location, Orientation, and Timecourse of Multiple Correlated Neural Sources Using MEG," Neuroimage In Revision.
    • Neuroimage
    • Wipf, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.