메뉴 건너뛰기




Volumn , Issue , 2009, Pages 2276-2278

Magnetic flux density measurement with balanced steady state free precession pulse sequence for MREIT: A simulation study

Author keywords

[No Author keywords available]

Indexed keywords

DATA ACQUISITION; ELECTRIC IMPEDANCE TOMOGRAPHY; MAGNETIC FIELDS; MAGNETIC FLUX; MAGNETIC RESONANCE; RESONANCE; SPIN POLARIZATION;

EID: 77950996651     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5335084     Document Type: Conference Paper
Times cited : (14)

References (12)
  • 2
    • 0028731158 scopus 로고
    • Impedance tomography using internal current density distribution measured by nuclear magnetic resonance
    • E. J. Woo, S. Y. Lee, and C. W. Mun, "Impedance tomography using internal current density distribution measured by nuclear magnetic resonance," SPIE, vol.2299, pp. 377-385, 1994.
    • (1994) SPIE , vol.2299 , pp. 377-385
    • Woo, E.J.1    Lee, S.Y.2    Mun, C.W.3
  • 8
    • 30344452316 scopus 로고    scopus 로고
    • High-resulution fMRI at 1.5T using balanced SSFP
    • K. L. Miller, S. M. Smith, P. Jezzard, and J. M. Pauly, "High-resulution fMRI at 1.5T using balanced SSFP", Mag. Reson. Med., vol.55, pp. 161-170, 2006.
    • (2006) Mag. Reson. Med. , vol.55 , pp. 161-170
    • Miller, K.L.1    Smith, S.M.2    Jezzard, P.3    Pauly, J.M.4
  • 9
    • 33846111314 scopus 로고    scopus 로고
    • Systematic investigation of balanced steady-state free precession for functional MRI in the human visual cortex at 3 Tesla
    • K. Zhong, J. Leupold, J. Henning, and O. Speck, "Systematic investigation of balanced steady-state free precession for functional MRI in the human visual cortex at 3 Tesla", Mag. Reson. Med., vol.57, pp. 67-73, 2007.
    • (2007) Mag. Reson. Med. , vol.57 , pp. 67-73
    • Zhong, K.1    Leupold, J.2    Henning, J.3    Speck, O.4
  • 10
    • 0023117716 scopus 로고
    • Rapid Fourier imaging using steady-state free precession
    • R. C. Hawkes, and S. Patz, "Rapid Fourier imaging using steady-state free precession", Mag. Reson. Med., vol.4, pp. 9-23, 1987.
    • (1987) Mag. Reson. Med. , vol.4 , pp. 9-23
    • Hawkes, R.C.1    Patz, S.2
  • 11
    • 0023872880 scopus 로고
    • An analysis of fast imaging sequences with steady-state transverse magnetization refocusing
    • Y. Zur, S. Stokar, and P. Bendel, "An analysis of fast imaging sequences with steady-state transverse magnetization refocusing", Mag. Reson. Med., vol.6, pp. 175-193, 1988.
    • (1988) Mag. Reson. Med. , vol.6 , pp. 175-193
    • Zur, Y.1    Stokar, S.2    Bendel, P.3
  • 12
    • 0037370514 scopus 로고    scopus 로고
    • Rapid combined T1 and T2 mapping using gradient recalled acquisition in steady state
    • S. C. L Deoni. B.K. Rutt, and T. M. Peters, "Rapid combined T1 and T2 mapping using gradient recalled acquisition in steady state", Mag. Reson. Med., vol.49, pp. 515-526, 2003.
    • (2003) Mag. Reson. Med. , vol.49 , pp. 515-526
    • Deoni, S.C.L.1    Rutt, B.K.2    Peters, T.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.