메뉴 건너뛰기




Volumn , Issue , 2009, Pages 3755-3758

Computer oriented image acquisition of the liver: Toward a better numerical model for radiofrequency ablation

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DATA ACQUISITION; IMAGE ACQUISITION; IMAGE SEGMENTATION; PHYSIOLOGICAL MODELS; PHYSIOLOGY;

EID: 77950993076     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5334539     Document Type: Conference Paper
Times cited : (2)

References (9)
  • 1
    • 0034853643 scopus 로고    scopus 로고
    • Image-guided radiofrequency tumor ablation: Challenges and opportunities-part i
    • Sept.
    • S. N. Goldberg and D. E. Dupuy, "Image-guided radiofrequency tumor ablation: challenges and opportunities-part i." J Vasc Interv Radiol, vol.12, no.9, pp. 1021-1032, Sept. 2001.
    • (2001) J Vasc Interv Radiol , vol.12 , Issue.9 , pp. 1021-1032
    • Goldberg, S.N.1    Dupuy, D.E.2
  • 3
    • 0017208259 scopus 로고
    • Electrophysiologic principles of radiofrequency lesion making
    • L. W. Organ, "Electrophysiologic principles of radiofrequency lesion making," Appl Neurophysiol, vol.39, pp. 69-76, 1976.
    • (1976) Appl Neurophysiol , vol.39 , pp. 69-76
    • Organ, L.W.1
  • 4
    • 0028332615 scopus 로고
    • Recent developments in modeling heat transfer in blood perfused tissues
    • H. Arkin, L. X. Xu, and K. R. Holmes, "Recent developments in modeling heat transfer in blood perfused tissues," Biomedical Engineering, IEEE Transactions on, vol.41, no.2, pp. 97-107, 1994.
    • (1994) Biomedical Engineering, IEEE Transactions on , vol.41 , Issue.2 , pp. 97-107
    • Arkin, H.1    Xu, L.X.2    Holmes, K.R.3
  • 5
    • 33644698566 scopus 로고    scopus 로고
    • Three-dimensional analysis for radio-frequency ablation of liver tumor with blood perfusion effect
    • Aug.
    • T. W. H. Sheu, C. W. Chou, S. F. Tsai, and P. C. Liang, "Three-dimensional analysis for radio-frequency ablation of liver tumor with blood perfusion effect," Computer Methods in Biomechanics and Biomedical Engineering, vol.8, no.4, pp. 229-240, Aug. 2005.
    • (2005) Computer Methods in Biomechanics and Biomedical Engineering , vol.8 , Issue.4 , pp. 229-240
    • Sheu, T.W.H.1    Chou, C.W.2    Tsai, S.F.3    Liang, P.C.4
  • 6
    • 84883841056 scopus 로고    scopus 로고
    • Numerical simulation of radio frequency ablation with state dependent material parameters in three space dimensions
    • ser. LNCS 4191, M. N. R. Larson, Ed., CeVis-Center for Complex Systems and Visualization, University of Bremen, Germany.: Springer-Verlag Berlin Heidelberg
    • T. Kröger, I. Altrogge, T. Preusser, P. L. Pereira, D. Schmidt, A. Weihusen, and H. O. Peitgen, "Numerical simulation of radio frequency ablation with state dependent material parameters in three space dimensions." in Medical Image Computing and Computer-Assisted Intervention, ser. LNCS 4191, M. N. R. Larson, Ed., vol.9. CeVis-Center for Complex Systems and Visualization, University of Bremen, Germany.: Springer-Verlag Berlin Heidelberg, 2006, pp. 380-388.
    • (2006) Medical Image Computing and Computer-Assisted Intervention , vol.9 , pp. 380-388
    • Kröger, T.1    Altrogge, I.2    Preusser, T.3    Pereira, P.L.4    Schmidt, D.5    Weihusen, A.6    Peitgen, H.O.7
  • 9
    • 68249121543 scopus 로고    scopus 로고
    • Comparison and evaluation of methods for liver segmentation from CT datasets
    • accepted for future publication
    • T. Heimann et al., "Comparison and evaluation of methods for liver segmentation from CT datasets," IEEE Transactions on Image Processing, 2009, accepted for future publication.
    • (2009) IEEE Transactions on Image Processing
    • Heimann, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.