메뉴 건너뛰기




Volumn , Issue , 2009, Pages 2707-2710

Decoupling of imaging and diffusion gradients in DTI

Author keywords

[No Author keywords available]

Indexed keywords

EIGENVALUES AND EIGENFUNCTIONS; LINEAR ALGEBRA; MATRIX ALGEBRA; OPTIMIZATION; SITE SELECTION;

EID: 77950981185     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5333395     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 3
    • 0030982536 scopus 로고    scopus 로고
    • Optimised diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brain
    • D. Xing, N. G. Papadakis, C. L.-H. Huang, V. M. Lee, T. A. Carpenter, and L. D. Hall, "Optimised diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brain," Magnetic Resonance Imaging, vol.15, no.7, pp. 771-784, 1997.
    • (1997) Magnetic Resonance Imaging , vol.15 , Issue.7 , pp. 771-784
    • Xing, D.1    Papadakis, N.G.2    Huang, C.L.-H.3    Lee, V.M.4    Carpenter, T.A.5    Hall, L.D.6
  • 4
    • 0031732550 scopus 로고    scopus 로고
    • A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging
    • M. E. Bastin, P. A. Armitage, and I. Marshall, "A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging," Magnetic Resonance Imaging, vol.16, no.7, pp. 773-785, 1998.
    • (1998) Magnetic Resonance Imaging , vol.16 , Issue.7 , pp. 773-785
    • Bastin, M.E.1    Armitage, P.A.2    Marshall, I.3
  • 5
    • 0035017270 scopus 로고    scopus 로고
    • Utilizing the diffusion-to-noise ratio to optimize magnetic resonance diffusion tensor acquisition strategies for improving measurements of diffusion anisotropy
    • P. A. Armitage and M. E. Bastin, "Utilizing the diffusion-to-noise ratio to optimize magnetic resonance diffusion tensor acquisition strategies for improving measurements of diffusion anisotropy," Magnetic Resonance in Medicine, vol.45, pp. 1056-1065, 2001.
    • (2001) Magnetic Resonance in Medicine , vol.45 , pp. 1056-1065
    • Armitage, P.A.1    Bastin, M.E.2
  • 6
    • 2342649531 scopus 로고    scopus 로고
    • Selection of the optimum b factor for diffusion-weighted magnetic resonance imaging assesment of ischemic stroke
    • P. B. Kingsley and W. G. Monahan, "Selection of the optimum b factor for diffusion-weighted magnetic resonance imaging assesment of ischemic stroke," Magnetic Resonance in Medicine, vol.51, pp. 996-1001, 2004.
    • (2004) Magnetic Resonance in Medicine , vol.51 , pp. 996-1001
    • Kingsley, P.B.1    Monahan, W.G.2
  • 7
    • 23044459584 scopus 로고    scopus 로고
    • Optimal imaging parameters for fiber-orientation estimation in diffusion MRI
    • D. C. Alexander and G. J. Barker, "Optimal imaging parameters for fiber-orientation estimation in diffusion MRI," Neuroimage, vol.27, pp. 357-367, 2005.
    • (2005) Neuroimage , vol.27 , pp. 357-367
    • Alexander, D.C.1    Barker, G.J.2
  • 8
    • 11344254685 scopus 로고    scopus 로고
    • (Mathematical) necessary conditions for the selection of gradient vectors in DTI
    • Feb.
    • A. Özcan, "(Mathematical) necessary conditions for the selection of gradient vectors in DTI," Journal of Magnetic Resonance, vol.172, no.2, pp. 238-241, Feb. 2005.
    • (2005) Journal of Magnetic Resonance , vol.172 , Issue.2 , pp. 238-241
    • Özcan, A.1
  • 10
    • 0030162959 scopus 로고    scopus 로고
    • Microstructral and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI
    • P. J. Basser and C. Pierpaoli, "Microstructral and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI," Journal of Magnetic Resonance Series B, vol.111, pp. 209-219, 1996.
    • (1996) Journal of Magnetic Resonance Series B , vol.111 , pp. 209-219
    • Basser, P.J.1    Pierpaoli, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.