메뉴 건너뛰기




Volumn , Issue , 2009, Pages 865-868

Static forces variation and pressure distribution in laryngoscopy performed by straight and curved blades

Author keywords

Laryngoscopy; Pressure distribution measurement

Indexed keywords

CARTILAGE; ENDOSCOPY; PRESSURE DISTRIBUTION;

EID: 77950974063     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5334422     Document Type: Conference Paper
Times cited : (8)

References (11)
  • 1
    • 15944396119 scopus 로고    scopus 로고
    • A comparison of 20 laryngoscope blades using an intubating manikin: Visual analogue scores and forces exerted during laryngoscopy
    • S. Rassam, A.R. Wilkers, J.E. Hall, and J.S. Mecklenburgh, "A comparison of 20 laryngoscope blades using an intubating manikin: visual analogue scores and forces exerted during laryngoscopy," Anaesthesia, vol.60, pp.384-394, 2005.
    • (2005) Anaesthesia , vol.60 , pp. 384-394
    • Rassam, S.1    Wilkers, A.R.2    Hall, J.E.3    Mecklenburgh, J.S.4
  • 2
    • 0042326302 scopus 로고    scopus 로고
    • A comparison of the forces exerted during laryngoscopy using disposable and non-disposable laryngoscope blades
    • A. Evans, R.S. Vaughan, J.E. Hall, J. Mecklenburgh, and A.R. Wilkes, "A comparison of the forces exerted during laryngoscopy using disposable and non-disposable laryngoscope blades," Anaesthesia, vol.58, pp. 869-873, 2003.
    • (2003) Anaesthesia , vol.58 , pp. 869-873
    • Evans, A.1    Vaughan, R.S.2    Hall, J.E.3    Mecklenburgh, J.4    Wilkes, A.R.5
  • 4
    • 0028566560 scopus 로고    scopus 로고
    • Forces acting on the maxillary incisor teeth during laryngoscopy using the Macintosh laryngoscope
    • M.J.L. Bucx et al. "Forces acting on the maxillary incisor teeth during laryngoscopy using the Macintosh laryngoscope," Anaesthesia, vol.49, pp. 1064-1070, 2003.
    • (2003) Anaesthesia , vol.49 , pp. 1064-1070
    • Bucx, M.J.L.1
  • 5
    • 0028908308 scopus 로고
    • A new device for measuring and recording the forces applied during laryngoscopy
    • E.P. McCoy, B.A. Austin, R.K. Mirakhur, and K.C. Wong, "A new device for measuring and recording the forces applied during laryngoscopy," Anaesthesia, vol.50, pp. 139-143, 1995.
    • (1995) Anaesthesia , vol.50 , pp. 139-143
    • McCoy, E.P.1    Austin, B.A.2    Mirakhur, R.K.3    Wong, K.C.4
  • 7
    • 0030031661 scopus 로고    scopus 로고
    • Force and torque vary between laryngoscopists and laryngoscope blades
    • R.H. Hastings, E.D. Hon, C. Nghiem, and E.A. Wahrenbrock, "Force and torque vary between laryngoscopists and laryngoscope blades," Anaesthesia & Analgesia, vol.82, pp. 462-468, 1996.
    • (1996) Anaesthesia & Analgesia , vol.82 , pp. 462-468
    • Hastings, R.H.1    Hon, E.D.2    Nghiem, C.3    Wahrenbrock, E.A.4
  • 8
    • 58749108338 scopus 로고    scopus 로고
    • Manual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation
    • B.G. Santoni, B.J. Hidman, C.M. Puttlitz, J.B. Weeks, M.P.T.N. Johnson, M.A. Maktabi, and M.M. Todd, "Manual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation," Anesthesiology, vol.110, pp. 24-31, 2009.
    • (2009) Anesthesiology , vol.110 , pp. 24-31
    • Santoni, B.G.1    Hidman, B.J.2    Puttlitz, C.M.3    Weeks, J.B.4    Johnson, M.P.T.N.5    Maktabi, M.A.6    Todd, M.M.7
  • 11
    • 15944396119 scopus 로고    scopus 로고
    • A comparison of 20 laryngoscope blades using an intubating manikin: Visual analogue scores and forces exerted during laryngoscopy
    • S. Rassam, A.R. Wilkes, J.E. Hall, and J. Mecklenburgh, "A comparison of 20 laryngoscope blades using an intubating manikin: visual analogue scores and forces exerted during laryngoscopy," Anaesthesia, vol.60, pp. 384-394, 2005.
    • (2005) Anaesthesia , vol.60 , pp. 384-394
    • Rassam, S.1    Wilkes, A.R.2    Hall, J.E.3    Mecklenburgh, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.