메뉴 건너뛰기




Volumn 15, Issue 3, 2010, Pages 131-134

Optical coherence tomography for bladder cancer - Ready as a surrogate for optical biopsy? - Results of a prospective mono-centre study

Author keywords

Bladder cancer; Diagnosis; Minimally invasive; Optical biopsy; Optical coherence tomography

Indexed keywords

ARTICLE; BLADDER BIOPSY; BLADDER CANCER; CANCER INVASION; CYSTOSCOPY; DEVICE; HUMAN; HUMAN TISSUE; LAMINA PROPRIA; MAJOR CLINICAL STUDY; MINIMALLY INVASIVE PROCEDURE; OPTICAL BIOPSY; OPTICAL COHERENCE TOMOGRAPHY; SENSITIVITY ANALYSIS; SENSITIVITY AND SPECIFICITY; COMPUTED TOMOGRAPHY SCANNER; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; FALSE POSITIVE RESULT; FLEXIBLE CYSTOSCOPE; HISTOPATHOLOGY; INTERMETHOD COMPARISON; PROSPECTIVE STUDY; TUMOR BIOPSY;

EID: 77950971043     PISSN: 09492321     EISSN: None     Source Type: Journal    
DOI: 10.1186/2047-783x-15-3-131     Document Type: Article
Times cited : (52)

References (13)
  • 1
    • 0034044430 scopus 로고    scopus 로고
    • Limitations of computerized tomography in staging invasive bladder cancer before radical cystectomy
    • Paik ML, Scolieri MJ, Brown SL, et al. Limitations of computerized tomography in staging invasive bladder cancer before radical cystectomy. J Urol. 2000;163(6): 1693-1696.
    • (2000) J Urol , vol.163 , Issue.6 , pp. 1693-1696
    • Paik, M.L.1    Scolieri, M.J.2    Brown, S.L.3
  • 4
    • 0035188381 scopus 로고    scopus 로고
    • Optical coherence tomography in dermatology: A review
    • DOI 10.1034/j.1600-0846.2001.007001001.x
    • Welzel J. Optical coherence tomography in dermatology: a review. Skin Res Technol. 2001;7(1): 1-9. (Pubitemid 32060993)
    • (2001) Skin Research and Technology , vol.7 , Issue.1 , pp. 1-9
    • Welzel, J.1
  • 6
    • 27744587902 scopus 로고    scopus 로고
    • Fluorescence guided optical coherence tomography for the diagnosis of early bladder cancer in a rat model
    • DOI 10.1097/01.ju.0000180413.98752.a1
    • Wang ZG, Durand DB, Schoenberg M, et al. Fluorescence guided optical coherence tomography for the diagnosis of early bladder cancer in a rat model. J Urol. 2005;174(6:)2376-2381. (Pubitemid 41611832)
    • (2005) Journal of Urology , vol.174 , Issue.6 , pp. 2376-2381
    • Wang, Z.G.1    Durand, D.B.2    Schoenberg, M.3    Pan, Y.T.4
  • 7
    • 57349197289 scopus 로고    scopus 로고
    • Optical coherence tomography (OCT): Ready for the diagnosis of a nephrogenic adenoma of the urinary bladder?
    • Karl A, Stepp H, Willmann E, et al. Optical coherence tomography (OCT): ready for the diagnosis of a nephrogenic adenoma of the urinary bladder? J Endourol. 2008; 22(11): 2429-2432.
    • (2008) J Endourol , vol.22 , Issue.11 , pp. 2429-2432
    • Karl, A.1    Stepp, H.2    Willmann, E.3
  • 8
    • 22244436962 scopus 로고    scopus 로고
    • Evaluation of superficial bladder transitional-cell carcinoma by optical coherence tomography
    • Manyak MJ, Gladkova ND, Makari JH, et al. Evaluation of superficial bladder transitional-cell carcinoma by optical coherence tomography. J Endourol. 2005;19(5): 570-574.
    • (2005) J Endourol , vol.19 , Issue.5 , pp. 570-574
    • Manyak, M.J.1    Gladkova, N.D.2    Makari, J.H.3
  • 9
    • 0036165630 scopus 로고    scopus 로고
    • In vivo optical coherence tomography feasibility for bladder disease
    • Zagaynova EV, Streltsova OS, Gladkova ND, et al. In vivo optical coherence tomography feasibility for bladder disease. J Urol. 2002;167(3): 1492-1496.
    • (2002) J Urol , vol.167 , Issue.3 , pp. 1492-1496
    • Zagaynova, E.V.1    Streltsova, O.S.2    Gladkova, N.D.3
  • 10
    • 22244436962 scopus 로고    scopus 로고
    • Evaluation of superficial bladder transitional-cell carcinoma by optical coherence tomography
    • Manyak MJ, Gladkova ND, Makari JH, et al. Evaluation of superficial bladder transitional-cell carcinoma by optical coherence tomography. J Endourol. 2005;19(5): 570-574.
    • (2005) J Endourol , vol.19 , Issue.5 , pp. 570-574
    • Manyak, M.J.1    Gladkova, N.D.2    Makari, J.H.3
  • 11
    • 45849103877 scopus 로고    scopus 로고
    • Optical Coherence Tomography of Cavernous Nerves: A Step Toward Real-Time Intraoperative Imaging during Nerve-Sparing Radical Prostatectomy
    • Jul
    • Rais-Bahrami S, Levinson AW, Fried NM, et al. Optical Coherence Tomography of Cavernous Nerves: A Step Toward Real-Time Intraoperative Imaging During Nerve-Sparing Radical Prostatectomy. Urology. 2008 Jul;72(1): 198-204.
    • (2008) Urology , vol.72 , Issue.1 , pp. 198-204
    • Rais-Bahrami, S.1    Levinson, A.W.2    Fried, N.M.3
  • 12
    • 34548863915 scopus 로고    scopus 로고
    • Second prize: Preliminary experience with the Niris optical coherence tomography system during laparoscopic and robotic prostatectomy
    • Aron M, Kaouk JH, Hegarty NJ, et al. Second prize: preliminary experience with the Niris optical coherence tomography system during laparoscopic and robotic prostatectomy. J Endourol. 2007;21(8): 814-818.
    • (2007) J Endourol , vol.21 , Issue.8 , pp. 814-818
    • Aron, M.1    Kaouk, J.H.2    Hegarty, N.J.3
  • 13
    • 60349122808 scopus 로고    scopus 로고
    • Fibered confocal microscopy of bladder tumors: An ex vivo study
    • Sonn GA, Mach KE, Jensen K, et al. Fibered confocal microscopy of bladder tumors: an ex vivo study. J Endourol. 2009;23(2): 197-201.
    • (2009) J Endourol , vol.23 , Issue.2 , pp. 197-201
    • Sonn, G.A.1    Mach, K.E.2    Jensen, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.