메뉴 건너뛰기




Volumn 34, Issue 3, 2010, Pages 323-328

A meta-analysis of the Gamma nail and dynamic hip screw in treating peritrochanteric fractures

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; DYNAMIC HIP SCREW; FEMUR PERITROCHANTERIC FRACTURE; FEMUR SHAFT FRACTURE; FEMUR TROCHANTERIC FRACTURE; GAMMA NAIL; HUMAN; INTERMETHOD COMPARISON; META ANALYSIS; ORTHOPEDIC EQUIPMENT; OSTEOSYNTHESIS; OUTCOME ASSESSMENT; PATIENT MOBILITY; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; REHABILITATION CARE; REOPERATION; SURGICAL INFECTION; SURGICAL MORTALITY; SURGICAL RISK; SURGICAL TECHNIQUE; SYSTEMATIC REVIEW; TREATMENT RESPONSE;

EID: 77950917721     PISSN: 03412695     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00264-009-0783-4     Document Type: Article
Times cited : (61)

References (23)
  • 1
    • 84937171000 scopus 로고
    • Trochanteric fractures treated by the sliding screw plate fixation method
    • 1:STN:280:DyaF2M%2FivFOhtA%3D%3D 14225321
    • DK Clawson 1964 Trochanteric fractures treated by the sliding screw plate fixation method J Trauma 4 737 752 1:STN:280:DyaF2M%2FivFOhtA%3D%3D 14225321
    • (1964) J Trauma , vol.4 , pp. 737-752
    • Clawson, D.K.1
  • 2
    • 0018344505 scopus 로고
    • Analysis of six hundred and twenty-two intertrochanteric hip fractures
    • 1:STN:280:DyaE1M7jtVGjtw%3D%3D 422605
    • RF Kyle RB Gustilo RF Premer 1979 Analysis of six hundred and twenty-two intertrochanteric hip fractures J Bone Joint Surg Am 61 216 221 1:STN:280:DyaE1M7jtVGjtw%3D%3D 422605
    • (1979) J Bone Joint Surg Am , vol.61 , pp. 216-221
    • Kyle, R.F.1    Gustilo, R.B.2    Premer, R.F.3
  • 3
    • 0347003738 scopus 로고    scopus 로고
    • Unstable trochanteric femoral fractures: Extramedullary or intramedullary fixation: Review of literature
    • DOI 10.1016/S0020-1383(03)00287-0
    • IB Schipper RK Marti C van der Werken 2004 Unstable trochanteric femoral fractures: extramedullary or intramedullary fixation. Review of literature Injury 35 142 151 10.1016/S0020-1383(03)00287-0 1:STN:280: DC%2BD2c%2Fjsleiuw%3D%3D 14736471 (Pubitemid 38084891)
    • (2004) Injury , vol.35 , Issue.2 , pp. 142-151
    • Schipper, I.B.1    Marti, R.K.2    Van Der Werken, C.3
  • 5
    • 0026764040 scopus 로고
    • Cutting-out of the dynamic hip screw related to its position
    • 1:STN:280:DyaK38zisFWntA%3D%3D 1624529
    • MJ Parker 1992 Cutting-out of the dynamic hip screw related to its position J Bone Joint Surg Br 74 625 1:STN:280:DyaK38zisFWntA%3D%3D 1624529
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 625
    • Parker, M.J.1
  • 6
    • 0036512930 scopus 로고    scopus 로고
    • Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95° screw-plate: A prospective, randomized study
    • C Sadowski A Lübbeke M Saudan N Riand R Stern P Hoffmeyer 2002 Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study J Bone Joint Surg Am 84-A 372 381 11886906 (Pubitemid 37107707)
    • (2002) Journal of Bone and Joint Surgery - Series A , vol.84 , Issue.3 , pp. 372-381
    • Sadowski, C.1    Lubbeke, A.2    Saudan, M.3    Riand, N.4    Stern, R.5    Hoffmeyer, P.6
  • 7
    • 33645083749 scopus 로고    scopus 로고
    • Misconceptions about the mechanical advantages of intramedullary devices for treatment of proximal femur fractures
    • DOI 10.1080/17453670610045876, PII L813153145468
    • M Zlowodzki M Bhandari GA Brown 2006 Misconceptions about the mechanical advantages of intramedullary devices for treatment of proximal femur fractures Acta Orthop 77 169 170 10.1080/17453670610045876 16534719 (Pubitemid 43879172)
    • (2006) Acta Orthopaedica , vol.77 , Issue.1 , pp. 169-170
    • Zlowodzki, M.1    Bhandari, M.2    Brown, G.A.3
  • 8
    • 0031866341 scopus 로고    scopus 로고
    • Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw - A randomised prospective trial
    • DOI 10.1007/s002640050231
    • SR Park JS Kang HS Kim WH Lee YH Kim 1998 Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw-a randomised prospective trial Int Orthop 22 157 160 10.1007/s002640050231 1:STN:280:DyaK1czpslGmsQ%3D%3D 9728307 (Pubitemid 28388727)
    • (1998) International Orthopaedics , vol.22 , Issue.3 , pp. 157-160
    • Park, S.-R.1    Kang, J.-S.2    Kim, H.-S.3    Lee, W.-H.4    Kim, Y.-H.5
  • 9
    • 0029616325 scopus 로고
    • Fixation of intertrochanteric hip fractures: Gamma nail versus dynamic hip screw. A randomized, prospective study
    • PJ O'Brien RN Meek PA Blachut HM Broekhuyse S Sabharwal 1995 Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomized, prospective study Can J Surg 38 516 520 7497366 (Pubitemid 26024416)
    • (1995) Canadian Journal of Surgery , vol.38 , Issue.6 , pp. 516-520
    • O'Brien, P.J.1    Meek, R.N.2    Blachut, P.A.3    Broekhuyse, H.M.4    Sabharwal, S.5
  • 10
    • 0035203607 scopus 로고    scopus 로고
    • Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the Femur
    • DOI 10.1097/00005131-200108000-00003
    • CI Adams CM Robinson CM Court-Brown MM McQueen 2001 Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur J Orthop Trauma 15 394 400 10.1097/00005131-200108000-00003 1:STN:280:DC%2BD3MvmvFKrsA%3D%3D 11514765 (Pubitemid 33130617)
    • (2001) Journal of Orthopaedic Trauma , vol.15 , Issue.6 , pp. 394-400
    • Adams, C.I.1    Robinson, C.M.2    Court-Brown, C.M.3    McQueen, M.M.4
  • 11
    • 0026504845 scopus 로고
    • Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients
    • 1:STN:280:DyaK383mvVWmuw%3D%3D 1587874
    • KS Leung WS So WY Shen PW Hui 1992 Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients J Bone Joint Surg Br 74 345 351 1:STN:280:DyaK383mvVWmuw%3D%3D 1587874
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 345-351
    • Leung, K.S.1    So, W.S.2    Shen, W.Y.3    Hui, P.W.4
  • 12
    • 0026090325 scopus 로고
    • Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw
    • 1:STN:280:DyaK3M7ntVehsw%3D%3D 2005167
    • SH Bridle AD Patel M Bircher PT Calvert 1991 Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw J Bone Joint Surg Br 73 330 334 1:STN:280:DyaK3M7ntVehsw%3D%3D 2005167
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 330-334
    • Bridle, S.H.1    Patel, A.D.2    Bircher, M.3    Calvert, P.T.4
  • 13
    • 0027170493 scopus 로고
    • A prospective randomised comparison of the dynamic hip screw and the gamma locking nail
    • PJ Radford M Needoff JK Webb 1993 A prospective randomised comparison of the dynamic hip screw and the gamma locking nail J Bone Joint Surg Br 75 5 789 793 1:STN:280:DyaK3szovVKktA%3D%3D 8376441 (Pubitemid 23267948)
    • (1993) Journal of Bone and Joint Surgery - Series B , vol.75 , Issue.5 , pp. 789-793
    • Radford, P.J.1    Needoff, M.2    Webb, J.K.3
  • 14
    • 0028307825 scopus 로고
    • Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients
    • AK Aune A Ekeland B Odegaard B Grøgaard A Alho 1994 Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients Acta Orthop Scand 65 127 130 1:STN:280:DyaK2c3ls1Wqtg%3D%3D 8197841 (Pubitemid 24153933)
    • (1994) Acta Orthopaedica Scandinavica , vol.65 , Issue.2 , pp. 127-130
    • Aune, A.K.1    Ekeland, A.2    Odegaard, B.3    Grogaard, B.4    Alho, A.5
  • 15
    • 2942720616 scopus 로고    scopus 로고
    • Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures (Cochrane Review)
    • John Wiley & Sons, Chichester
    • Parker MJ, Handoll HHG (2004) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures (Cochrane Review). In: The Cochrane Library, Issue 3. John Wiley & Sons, Chichester
    • (2004) The Cochrane Library , Issue.3
    • Parker, M.J.1    Handoll, H.H.G.2
  • 16
    • 0032059914 scopus 로고    scopus 로고
    • Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the gamma nail and compression hip screw
    • JE Madsen L Naess AK Aune A Alho A Ekeland K Strømsøe 1998 Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw J Orthop Trauma 12 1 241 248 10.1097/00005131-199805000- 00005 1:STN:280:DyaK1c3otVOmtQ%3D%3D 9619458 (Pubitemid 128454115)
    • (1998) Journal of Orthopaedic Trauma , vol.12 , Issue.4 , pp. 241-248
    • Madsen, J.E.1    Naess, L.2    Aune, A.K.3    Alho, A.4    Ekeland, A.5    Stromsoe, K.6
  • 17
    • 0028866619 scopus 로고
    • Comparison of dynamic hip screw and gamma nail: A prospective, randomized, controlled trial
    • 10.1016/0020-1383(95)00126-T 1:STN:280:DyaK287kt1Kntg%3D%3D 8550169
    • MS Butt SJ Krikler S Nafie MS Ali 1995 Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial Injury 26 2 615 618 10.1016/0020-1383(95)00126-T 1:STN:280:DyaK287kt1Kntg%3D%3D 8550169
    • (1995) Injury , vol.26 , Issue.2 , pp. 615-618
    • Butt, M.S.1    Krikler, S.J.2    Nafie, S.3    Ali, M.S.4
  • 18
    • 0016829044 scopus 로고
    • The treatment of trochanteric hip fractures using a compressing screw
    • 1:STN:280:DyaE2M7jtlKntw%3D%3D 1123368
    • ML Ecker JJ Joyce 3rd EJ Kohl 1975 The treatment of trochanteric hip fractures using a compressing screw J Bone Joint Surg Am 57 1 23 27 1:STN:280:DyaE2M7jtlKntw%3D%3D 1123368
    • (1975) J Bone Joint Surg Am , vol.57 , Issue.1 , pp. 23-27
    • Ecker, M.L.1    Joyce III, J.J.2    Kohl, E.J.3
  • 19
    • 0019295916 scopus 로고
    • Unstable trochanteric fractures. A comparative analysis of four methods of internal fixation
    • JS Jensen S Sonne-Holm E Tøndevold 1980 Unstable trochanteric fractures. A comparative analysis of four methods of internal fixation Acta Orthop Scand 51 6 949 962 1:STN:280:DyaL3M7ls1amtQ%3D%3D 7211302 (Pubitemid 11146071)
    • (1980) Acta Orthopaedica Scandinavica , vol.51 , Issue.6 , pp. 949-962
    • Jensen, J.S.1    Sonne-Holm, S.2    Tondevold, E.3
  • 20
    • 33645286249 scopus 로고    scopus 로고
    • Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures
    • 10.1007/s00264-005-0028-0 16496147
    • HW Jones P Johnston M Parker 2006 Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures Int Orthop 30 69 78 10.1007/s00264-005-0028-0 16496147
    • (2006) Int Orthop , vol.30 , pp. 69-78
    • Jones, H.W.1    Johnston, P.2    Parker, M.3
  • 21
    • 0033834484 scopus 로고    scopus 로고
    • What contributions do languages other than English make on the results of meta-analyses?
    • 10.1016/S0895-4356(00)00188-8 1:STN:280:DC%2BD3M%2FhtFWqsw%3D%3D 11004423
    • D Moher B Pham TP Klassen KF Schulz JA Berlin AR Jadad A Liberati 2000 What contributions do languages other than English make on the results of meta-analyses? J Clin Epidemiol 53 3 964 972 10.1016/S0895-4356(00)00188-8 1:STN:280:DC%2BD3M%2FhtFWqsw%3D%3D 11004423
    • (2000) J Clin Epidemiol , vol.53 , Issue.3 , pp. 964-972
    • Moher, D.1    Pham, B.2    Klassen, T.P.3    Schulz, K.F.4    Berlin, J.A.5    Jadad, A.R.6    Liberati, A.7
  • 22
    • 0028895409 scopus 로고
    • Methodologic guidelines for systematic reviews of randomized control trials in health care from the Potsdam Consultation on Meta-Analysis
    • 10.1016/0895-4356(94)00172-M 1:STN:280:DyaK2M7ls1WitA%3D%3D 7853043
    • DJ Cook DL Sackett WO Spitzer 1995 Methodologic guidelines for systematic reviews of randomized control trials in health care from the Potsdam Consultation on Meta-Analysis J Clin Epidemiol 48 1 167 171 10.1016/0895- 4356(94)00172-M 1:STN:280:DyaK2M7ls1WitA%3D%3D 7853043
    • (1995) J Clin Epidemiol , vol.48 , Issue.1 , pp. 167-171
    • Cook, D.J.1    Sackett, D.L.2    Spitzer, W.O.3
  • 23
    • 0030742003 scopus 로고    scopus 로고
    • The promise and problems of meta-analysis
    • DOI 10.1056/NEJM199708213370810
    • JC Bailar 3rd 1997 The promise and problems of meta-analysis N Engl J Med 337 8 559 561 10.1056/NEJM199708213370810 9262502 (Pubitemid 27352025)
    • (1997) New England Journal of Medicine , vol.337 , Issue.8 , pp. 559-561
    • Bail, J.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.