메뉴 건너뛰기




Volumn 34, Issue 3, 2010, Pages 355-359

Clinical use of a new tourniquet system for foot and ankle surgery

Author keywords

[No Author keywords available]

Indexed keywords

ACHILLES TENDON; ADOLESCENT; ADULT; AGED; ANKLE; ARTHROSCOPY; ARTICLE; BLOOD PRESSURE MEASUREMENT; BONE GRAFT; CHILD; CLINICAL EVALUATION; EQUIPMENT DESIGN; FEMALE; FOOT SURGERY; HUMAN; JOINT SURGERY; MAJOR CLINICAL STUDY; MALE; OPEN REDUCTION; OSTEOSYNTHESIS; OSTEOTOMY; POSTOPERATIVE HEMORRHAGE; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; SCHOOL CHILD; SURGICAL TECHNIQUE; SYNOVECTOMY; SYSTOLIC BLOOD PRESSURE; TENDON RECONSTRUCTION; TOURNIQUET;

EID: 77950917229     PISSN: 03412695     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00264-009-0804-3     Document Type: Article
Times cited : (10)

References (18)
  • 1
    • 0029061552 scopus 로고
    • Surgical hemostasis by pneumatic ankle tourniquet during 3027 podiatric operations
    • 10.1016/S1067-2516(09)80054-9 1:STN:280:DyaK28%2FitlKntQ%3D%3D 7550186
    • R Derner J Buckholts 1995 Surgical hemostasis by pneumatic ankle tourniquet during 3027 podiatric operations J Foot Ankle Surg 34 236 246 10.1016/S1067-2516(09)80054-9 1:STN:280:DyaK28%2FitlKntQ%3D%3D 7550186
    • (1995) J Foot Ankle Surg , vol.34 , pp. 236-246
    • Derner, R.1    Buckholts, J.2
  • 2
    • 0027408219 scopus 로고
    • Occlusion of arterial flow in the extremities at subsystolic pressures through the use of wide tourniquet cuffs
    • B Graham MJ Breault JA McEwen RW McGraw 1993 Occlusion of arterial flow in the extremities at subsystolic pressures through the use of wide tourniquet cuffs Clin Orthop 286 257 261 8425355 (Pubitemid 23059496)
    • (1993) Clinical Orthopaedics and Related Research , Issue.286 , pp. 257-261
    • Graham, B.1    Breault, M.J.2    McEwen, J.A.3    McGraw, R.W.4
  • 3
    • 16244409779 scopus 로고    scopus 로고
    • Effect of tourniquet pressure on perioperative blood loss associated with cementless total knee arthroplasty: A prospective, randomized study
    • DOI 10.1016/j.arth.2004.10.001
    • Y Ishii Y Matsuda 2005 Effect of tourniquet pressure on perioperative blood loss associated with cementless total knee arthroplasty: a prospective, randomized study J Arthroplasty 20 325 330 10.1016/j.arth.2004.10.001 15809950 (Pubitemid 40460799)
    • (2005) Journal of Arthroplasty , vol.20 , Issue.3 , pp. 325-330
    • Ishii, Y.1    Matsuda, Y.2
  • 4
    • 39049114497 scopus 로고    scopus 로고
    • A new tourniquet system that determines pressures in synchrony with systolic blood pressure
    • DOI 10.1007/s00402-007-0446-0
    • Y Ishii H Noguchi Y Matsuda M Takeda T Higashihara 2008 A new tourniquet system that determines pressures in synchrony with systolic blood pressure in total knee arthroplasty J Arthroplasty 23 1050 1056 10.1016/j.arth.2007.08.012 18534383 (Pubitemid 351234312)
    • (2008) Archives of Orthopaedic and Trauma Surgery , vol.128 , Issue.3 , pp. 297-300
    • Ishii, Y.1    Noguchi, H.2    Matsuda, Y.3    Takeda, M.4    Higashihara, T.-I.5
  • 5
    • 16844386313 scopus 로고    scopus 로고
    • Tourniquets may increase postoperative swelling and pain after internal fixation of ankle fractures
    • DOI 10.1097/01.blo.0000151849.37260.0a
    • G Konrad M Markmiller A Lenich E Mayr A Rüter 2005 Tourniquets may increase postoperative swelling and pain after internal fixation of ankle fractures Clin Orthop 433 189 194 15805957 (Pubitemid 40489269)
    • (2005) Clinical Orthopaedics and Related Research , Issue.433 , pp. 189-194
    • Konrad, G.1    Markmiller, M.2    Lenich, A.3    Mayr, E.4    Ruter, A.5
  • 6
    • 0027310481 scopus 로고
    • Use of a tourniquet in the internal fixation of fractures of the distal part of the fibula. A prospective, randomized trial
    • N Maffulli V Testa G Capasso 1993 Use of a tourniquet in the internal fixation of fractures of the distal part of the fibula: a prospective, randomized trial J Bone Joint Surg Am 75 700 703 1:STN:280:DyaK3s3ntlOmtg%3D%3D 8501085 (Pubitemid 23199103)
    • (1993) Journal of Bone and Joint Surgery - Series A , vol.75 , Issue.5 , pp. 700-703
    • Maffulli, N.1    Testa, V.2    Capasso, G.3
  • 7
    • 0032784186 scopus 로고    scopus 로고
    • Pneumatic ankle tourniquets: Physiological factors related to minimal arterial occlusion pressure
    • KA Massey C Blakeslee W Martin HS Pitkow 1999 Pneumatic ankle tourniquets: physiological factors related to minimal arterial occlusion pressure J Foot Ankle Surg 38 306 307 10.1016/S1067-2516(99)80067-2 (Pubitemid 29398729)
    • (1999) Journal of Foot and Ankle Surgery , vol.38 , Issue.4 , pp. 256-263
    • Massey, K.A.1    Blakeslee, C.2    Martin, W.3    Pitkow, H.S.4
  • 8
    • 0023521338 scopus 로고
    • Wide tourniquets eliminate blood flow at low inflation pressures
    • 1:STN:280:DyaL1c%2FovVGksA%3D%3D 2961797
    • MR Moore SR Grafin AR Hargens 1987 Wide tourniquets eliminate blood flow at low inflation pressures J Hand Surg Am 12 1006 1011 1:STN:280: DyaL1c%2FovVGksA%3D%3D 2961797
    • (1987) J Hand Surg Am , vol.12 , pp. 1006-1011
    • Moore, M.R.1    Grafin, S.R.2    Hargens, A.R.3
  • 9
    • 0022624940 scopus 로고
    • A low-pressure tourniquet system for the lower limb
    • DOI 10.1016/0020-1383(86)90020-3
    • A Muirhead RJ Newman 1986 A low-pressure tourniquet system for the lower limb Injury 17 53 54 10.1016/0020-1383(86)90020-3 1:STN:280: DyaL2s%2Fjt1egsA%3D%3D 3770891 (Pubitemid 16147768)
    • (1986) Injury , vol.17 , Issue.1 , pp. 53-54
    • Muirhead, A.1    Newman, R.J.2
  • 10
    • 0021015797 scopus 로고
    • Double tourniquet with linked mercury manometers for hand surgery
    • 1:STN:280:DyaL2c%2Fmt1ymuw%3D%3D 6643976
    • RJ Neimkin RJ Smith 1983 Double tourniquet with linked mercury manometers for hand surgery J Hand Surg Am 8 938 941 1:STN:280:DyaL2c%2Fmt1ymuw%3D%3D 6643976
    • (1983) J Hand Surg Am , vol.8 , pp. 938-941
    • Neimkin, R.J.1    Smith, R.J.2
  • 11
    • 0022497865 scopus 로고
    • A safe and effective low pressure tourniquet: A prospective evaluation
    • RJ Newman A Muirhead 1986 A safe and effective low-pressure tourniquet: a prospective evaluation J Bone Joint Surg Br 68 625 628 1:STN:280: DyaL283nvVemug%3D%3D 3525572 (Pubitemid 16035357)
    • (1986) Journal of Bone and Joint Surgery - Series B , vol.68 , Issue.4 , pp. 625-628
    • Newman, R.J.1    Muirhead, A.2
  • 12
    • 0031441927 scopus 로고    scopus 로고
    • The relationship between the use of tourniquet and the intensity of postoperative pain in surgically treated malleolar fractures
    • H Omeroǧlu U Günel A Biçimoǧlu AY Tabak A Uçaner O Güney 1997 The relationship between the use of tourniquet and the intensity of postoperative pain in surgically treated malleolar fractures Foot Ankle Int 18 798 802 9429882 (Pubitemid 28016564)
    • (1997) Foot and Ankle International , vol.18 , Issue.12 , pp. 798-802
    • Omeroglu, H.1    Gunel, U.2    Bicimoglu, A.3    Tabak, A.Y.4    Ucaner, A.5    Guney, O.6
  • 13
    • 0028574105 scopus 로고
    • Low pressure pneumatic tourniquets: Effectiveness at minimum recommended inflation pressures
    • 1:STN:280:DyaK2M3gtFOhsw%3D%3D 7894409
    • RS Pauers MA Carocci 1994 Low pressure pneumatic tourniquets: effectiveness at minimum recommended inflation pressures J Foot Ankle Surg 33 605 609 1:STN:280:DyaK2M3gtFOhsw%3D%3D 7894409
    • (1994) J Foot Ankle Surg , vol.33 , pp. 605-609
    • Pauers, R.S.1    Carocci, M.A.2
  • 14
    • 0020510458 scopus 로고
    • Tourniquet hemostasis. A clinical study
    • 6861401
    • HS Reid RA Camp WH Jacob 1983 Tourniquet hemostasis. A clinical study Clin Orthop 177 230 234 6861401
    • (1983) Clin Orthop , vol.177 , pp. 230-234
    • Reid, H.S.1    Camp, R.A.2    Jacob, W.H.3
  • 16
    • 0142243314 scopus 로고    scopus 로고
    • Controlled hypotension and minimal inflation pressure: A new approach for pneumatic tourniquet application in upper limb surgery
    • B Tuncali A Karci AK Bacakoglu BE Tuncali A Ekin 2003 Controlled hypotension and minimal inflation pressure: a new approach for pneumatic tourniquet application in upper limb surgery Anesth Analg 97 1529 1532 10.1213/01.ANE.0000081660.97731.91 14570681 (Pubitemid 37310163)
    • (2003) Anesthesia and Analgesia , vol.97 , Issue.5 , pp. 1529-1532
    • Tuncali, B.1    Karci, A.2    Bacakoglu, A.K.3    Tuncali, B.E.4    Ekin, A.5
  • 18
    • 8644254255 scopus 로고    scopus 로고
    • Wide contoured thigh cuffs and automated limb occlusion measurement allow lower tourniquet pressures
    • DOI 10.1097/01.blo.0000142625.82654.b3
    • AS Younger JA McEwen K Inkpen 2004 Wide countered thigh cuffs and automated limb occlusion measurement allow lower tourniquet pressures Clin Orthop 428 286 293 10.1097/01.blo.0000142625.82654.b3 15534554 (Pubitemid 39506185)
    • (2004) Clinical Orthopaedics and Related Research , Issue.428 , pp. 286-293
    • Younger, A.S.E.1    McEwen, J.A.2    Inkpen, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.