메뉴 건너뛰기




Volumn , Issue , 2008, Pages

Evaluation of pivot shift in the anterior cruciate ligament-injured knee using inertial and magnetic sensors

Author keywords

Anterior Cruciate Ligament; Inertial and magnetic sensor; Kinematics; Knee joint; Pivot shift; Quantification; Wavelet

Indexed keywords

ANALYSIS METHOD; ANTERIOR CRUCIATE LIGAMENT; ANTERIOR CRUCIATE LIGAMENT INJURY; INERTIAL AND MAGNETIC SENSOR; KNEE JOINT; KNEE MOVEMENTS; MAXIMUM ACCELERATION; QUANTITATIVE ASSESSMENTS; QUANTITATIVE EVALUATION; SUBJECTIVE EVALUATIONS; VIDEO IMAGE; WAVELET TRANSFORMATIONS;

EID: 77950825399     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (10)
  • 2
    • 0001547402 scopus 로고
    • Pivot shift: A clinical sign of symptomatic anterior cruciate insufficiency
    • R. D. Galway et al., "Pivot shift: a clinical sign of symptomatic anterior cruciate insufficiency," J. Bone Joint Surge Br., Vol.54-B, pp. 763-764, 1972.
    • (1972) J. Bone Joint Surge Br. , vol.54 B , pp. 763-764
    • Galway, R.D.1
  • 3
    • 0031859236 scopus 로고    scopus 로고
    • The pivot-shift phenomenon: A clinical and biomechanical perspective
    • A. M. J. Bull et al., "The pivot-shift phenomenon: a clinical and biomechanical perspective," The Knee, Vol.5, pp. 141-158, 1998.
    • (1998) The Knee , vol.5 , pp. 141-158
    • Bull, A.M.J.1
  • 5
    • 33846071075 scopus 로고    scopus 로고
    • Reliability and usefulness of a new in vivo measurement system of the pivot shift
    • S. Kubo et al., "Reliability and Usefulness of a new In Vivo Measurement System of the Pivot Shift," Clin. Orthop. Relat. Res., pp. 454-458, 2007.
    • (2007) Clin. Orthop. Relat. Res. , pp. 454-458
    • Kubo, S.1
  • 6
    • 34250844512 scopus 로고    scopus 로고
    • In vivo measurement of the pivot-shift test in the anterior cruciate ligament-deficient knee using an electromagnetic device
    • Y. Hoshino et al., "In Vivo Measurement of the Pivot-Shift Test in the Anterior Cruciate Ligament-Deficient Knee Using an Electromagnetic Device," The American Journal of Sports Medicine, Vol.35, pp. 1098-1104, 2007.
    • (2007) The American Journal of Sports Medicine , vol.35 , pp. 1098-1104
    • Hoshino, Y.1
  • 7
    • 0016667393 scopus 로고
    • A computer program for direct linear transformation solution of the colinearity condition, and some applications of it
    • N. R. Miller et al., "A computer program for direct linear transformation solution of the colinearity condition, and some applications of it," Proc. of the Sympo. on Close-Range Photogrammetric Systems, pp. 420-476, 1975.
    • (1975) Proc. of the Sympo. on Close-Range Photogrammetric Systems , pp. 420-476
    • Miller, N.R.1
  • 8
    • 12744265302 scopus 로고    scopus 로고
    • A new complex wavelet: RI-Spline wavelet and its application to signal processing
    • Z. Zhang et al., "A new complex wavelet: RI-Spline wavelet and its application to signal processing," Proceedings of the 41st SICE Annual Conference, Vol.4, pp. 2496-2501, 2002.
    • (2002) Proceedings of the 41st SICE Annual Conference , vol.4 , pp. 2496-2501
    • Zhang, Z.1
  • 9
    • 23844513274 scopus 로고    scopus 로고
    • A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes
    • H. Dejnabadi et al., "A New Approach to Accurate Measurement of Uniaxial Joint Angles Based on a Combination of Accelerometers and Gyroscopes," IEEE Trans. on Biomedical Engineering, Vol.52, No.8, pp. 1478-1484,2005.
    • (2005) IEEE Trans. on Biomedical Engineering , vol.52 , Issue.8 , pp. 1478-1484
    • Dejnabadi, H.1
  • 10
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of threedimensional motions: Application to the knee
    • E. S. Grood et al., "A Joint Coordinate System for the Clinical Description of ThreeDimensional Motions: Application to the Knee," J. of Biomechanics, Vol.105, No.2, pp. 136144, 1983.
    • (1983) J. of Biomechanics , vol.105 , Issue.2 , pp. 136144
    • Grood, E.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.