메뉴 건너뛰기




Volumn 29, Issue 1, 2010, Pages 42-47

Measurement of human metabolism

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOMEDICAL ENGINEERING; BODY WEIGHT; EATING; ENERGY METABOLISM; EQUIPMENT DESIGN; HUMAN; INSTRUMENTATION; METHODOLOGY; MONITORING; OBESITY; PATHOPHYSIOLOGY;

EID: 77950641945     PISSN: 07395175     EISSN: None     Source Type: Journal    
DOI: 10.1109/MEMB.2009.935463     Document Type: Article
Times cited : (20)

References (21)
  • 2
    • 0032910326 scopus 로고    scopus 로고
    • Santorio Sanctorius (1561-1636)-Founding father of metabolic balance studies
    • G. Eknoyan, "Santorio Sanctorius (1561-1636)-Founding father of metabolic balance studies," Amer. J. Nephrol., vol. 19, pp. 226-233, 1999.
    • (1999) Amer. J. Nephrol. , vol.19 , pp. 226-233
    • Eknoyan, G.1
  • 3
    • 33144472648 scopus 로고    scopus 로고
    • Measurement of energy expenditure
    • Oct
    • J. A. Levine, "Measurement of energy expenditure," Public Health Nutr., vol. 8, pp. 1123-1132, Oct. 2005.
    • (2005) Public Health Nutr. , vol.8 , pp. 1123-1132
    • Levine, J.A.1
  • 4
    • 0033936521 scopus 로고    scopus 로고
    • An improved estimation of mean body temperature using combined direct calorimetry and thermometry
    • June
    • J. W. Snellen, "An improved estimation of mean body temperature using combined direct calorimetry and thermometry," Eur. J. Appl. Physiol., vol. 82, pp. 188-196, June 2000.
    • (2000) Eur. J. Appl. Physiol. , vol.82 , pp. 188-196
    • Snellen, J.W.1
  • 5
    • 0020673626 scopus 로고
    • Technical description and performance characteristics of a human whole-body calorimeter
    • Jan
    • J. W. Snellen, K. S. Chang, and W. Smith, "Technical description and performance characteristics of a human whole-body calorimeter," Med. Biol. Eng. Comput., vol. 21, pp. 9-20, Jan. 1983.
    • (1983) Med. Biol. Eng. Comput. , vol.21 , pp. 9-20
    • Snellen, J.W.1    Chang, K.S.2    Smith, W.3
  • 6
    • 0018743958 scopus 로고
    • An isothermic, gradient-free, whole-body calorimeter for long-term investigations of energy balance in man
    • July
    • E. Tschegg, A. Sigmund, V. Veitl, P. Schmid, and K. Irsigler, "An isothermic, gradient-free, whole-body calorimeter for long-term investigations of energy balance in man," Metabolism, vol. 28, pp. 764-770, July 1979.
    • (1979) Metabolism , vol.28 , pp. 764-770
    • Tschegg, E.1    Sigmund, A.2    Veitl, V.3    Schmid, P.4    Irsigler, K.5
  • 7
    • 0022657033 scopus 로고
    • Description of a human direct calorimeter, with a note on the energy cost of clerical work
    • Jan
    • J. D. Webster, G. Welsh, P. Pacy, and J. S. Garrow, "Description of a human direct calorimeter, with a note on the energy cost of clerical work," Br. J. Nutr., vol. 55, pp. 1-6, Jan. 1986.
    • (1986) Br. J. Nutr. , vol.55 , pp. 1-6
    • Webster, J.D.1    Welsh, G.2    Pacy, P.3    Garrow, J.S.4
  • 8
    • 0025420169 scopus 로고
    • New methods for calculating metabolic rate with special reference to protein metabolism 1949
    • May-June
    • J. B. Weir, "New methods for calculating metabolic rate with special reference to protein metabolism 1949," Nutrition, vol. 6, pp. 213-221, May-June 1990.
    • (1990) Nutrition , vol.6 , pp. 213-221
    • Weir, J.B.1
  • 9
    • 3343021881 scopus 로고    scopus 로고
    • Accuracy and reliability of a Cosmed K4b2 portable gas analysis system
    • Mar
    • R. Duffield, B. Dawson, H. C. Pinnington, and P. Wong, "Accuracy and reliability of a Cosmed K4b2 portable gas analysis system," J. Sci. Med. Sport., vol. 7, pp. 11-22, Mar. 2004.
    • (2004) J. Sci. Med. Sport. , vol.7 , pp. 11-22
    • Duffield, R.1    Dawson, B.2    Pinnington, H.C.3    Wong, P.4
  • 11
    • 0028235249 scopus 로고
    • Modification of a whole room indirect calorimeter for measurement of rapid changes in energy expenditure
    • June
    • M. Sun, G. W. Reed, and J. O. Hill, "Modification of a whole room indirect calorimeter for measurement of rapid changes in energy expenditure," J. Appl. Physiol., vol. 76, pp. 2686-2691, June 1994.
    • (1994) J. Appl. Physiol. , vol.76 , pp. 2686-2691
    • Sun, M.1    Reed, G.W.2    Hill, J.O.3
  • 12
    • 0028802042 scopus 로고
    • Closed-loop control of carbon dioxide concentration and pressure improves response of room respiration calorimeters
    • J. K. Moon, F. A. Vohra, O. S. Valerio Jimenez, M. R. Puyau, and N. F. Butte, "Closed-loop control of carbon dioxide concentration and pressure improves response of room respiration calorimeters," J. Nutr., vol. 125, pp. 220-228, 1995.
    • (1995) J. Nutr. , vol.125 , pp. 220-228
    • Moon, J.K.1    Vohra, F.A.2    Valerio Jimenez, O.S.3    Puyau, M.R.4    Butte, N.F.5
  • 13
    • 0023228588 scopus 로고
    • Precision of the doubly labelled water method using the two-point calculation
    • May
    • D. A. Schoeller and P. B. Taylor, "Precision of the doubly labelled water method using the two-point calculation," Hum. Nutr. Clin. Nutr., vol. 41, pp. 215-223, May 1987.
    • (1987) Hum. Nutr. Clin. Nutr. , vol.41 , pp. 215-223
    • Schoeller, D.A.1    Taylor, P.B.2
  • 14
    • 28044467315 scopus 로고    scopus 로고
    • The technology of accelerometry-based activity monitors: Current and future
    • Nov
    • K. Y. Chen and D. R. Bassett, Jr., "The technology of accelerometry-based activity monitors: current and future," Med. Sci. Sports Exerc., vol. 37, pp. S490-S500, Nov. 2005.
    • (2005) Med. Sci. Sports Exerc. , vol.37
    • Chen, K.Y.1    Bassett Jr., D.R.2
  • 15
    • 63049091166 scopus 로고    scopus 로고
    • Assessment of physical activity: A critical appraisal
    • K. R. Westerterp, "Assessment of physical activity: A critical appraisal," Eur. J. Appl. Physiol., vol. 105, pp. 823-828, 2009.
    • (2009) Eur. J. Appl. Physiol. , vol.105 , pp. 823-828
    • Westerterp, K.R.1
  • 16
    • 3542996061 scopus 로고    scopus 로고
    • Use of heart rate montiors to assess physical activity
    • G. Welk, Ed. Champaign, IL: Human Kinetics
    • K. F. Janz, "Use of heart rate montiors to assess physical activity," in Physical Activity Assessments for Health-Related Research, G. Welk, Ed. Champaign, IL: Human Kinetics, 2002, pp. 143-161.
    • (2002) Physical Activity Assessments for Health-Related Research , pp. 143-161
    • Janz, K.F.1
  • 17
    • 0011642404 scopus 로고    scopus 로고
    • Validity and reliability issues in objective monitoring of physical activity
    • June
    • D. R. Bassett, Jr., "Validity and reliability issues in objective monitoring of physical activity," Res. Q. Exerc. Sport, vol. 71, pp. S30-S36, June 2000.
    • (2000) Res. Q. Exerc. Sport , vol.71
    • Bassett Jr., D.R.1
  • 18
    • 33646526925 scopus 로고    scopus 로고
    • Validity of the polar S810 heart rate monitor to measure R-R intervals at rest
    • May
    • F. X. Gamelin, S. Berthoin, and L. Bosquet, "Validity of the polar S810 heart rate monitor to measure R-R intervals at rest," Med. Sci. Sports Exerc., vol. 38, pp. 887-893, May 2006.
    • (2006) Med. Sci. Sports Exerc. , vol.38 , pp. 887-893
    • Gamelin, F.X.1    Berthoin, S.2    Bosquet, L.3
  • 19
    • 13844298768 scopus 로고    scopus 로고
    • Comparison of Polar 810s and an ambulatory ECG system for RR interval measurement during progressive exercise
    • Jan.-Feb
    • M. Kingsley, M. J. Lewis, and R. E. Marson, "Comparison of Polar 810s and an ambulatory ECG system for RR interval measurement during progressive exercise," Int. J. Sports Med., vol. 26, pp. 39-44, Jan.-Feb. 2005.
    • (2005) Int. J. Sports Med. , vol.26 , pp. 39-44
    • Kingsley, M.1    Lewis, M.J.2    Marson, R.E.3
  • 20
  • 21
    • 34249106180 scopus 로고    scopus 로고
    • Heart rate response to therapeutic riding in children with cerebral palsy: An exploratory study
    • Summer
    • L. N. Dirienzo, L. T. Dirienzo, and D. A. Baceski, "Heart rate response to therapeutic riding in children with cerebral palsy: An exploratory study," Pediatr. Phys. Ther., vol. 19, pp. 160-165, Summer 2007.
    • (2007) Pediatr. Phys. Ther. , vol.19 , pp. 160-165
    • Dirienzo, L.N.1    Dirienzo, L.T.2    Baceski, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.