메뉴 건너뛰기




Volumn 93, Issue 1, 2010, Pages 15-19

Radiation dose optimization in thoracic imaging

Author keywords

CT; Injurious effects lung; Radiations

Indexed keywords

AUTOMATION; CANCER RISK; COMPUTER ASSISTED TOMOGRAPHY; CONTROL SYSTEM; DIAGNOSTIC IMAGING; HEALTH SURVEY; HUMAN; IMAGE QUALITY; LOW ENERGY RADIATION; LUNG ANGIOGRAPHY; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE FRACTIONATION; REFERENCE VALUE; REVIEW; THORAX;

EID: 77950619794     PISSN: 17802393     EISSN: None     Source Type: Journal    
DOI: 10.5334/jbr-btr.31     Document Type: Review
Times cited : (8)

References (24)
  • 1
    • 0038037974 scopus 로고    scopus 로고
    • Radiation exposure at chest CT: A statement of the fleischner society
    • DOI 10.1148/radiol.2281020874
    • Mayo J.R., Aldrich J., Muller NL.: Radiation exposure at chest CT: a statement of the Fleischner Society. Radiology, 2003, 228: 15-21. (Pubitemid 36736063)
    • (2003) Radiology , vol.228 , Issue.1 , pp. 15-21
    • Mayo, J.R.1    Aldrich, J.2    Muller, N.L.3
  • 2
    • 2142695134 scopus 로고    scopus 로고
    • Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer
    • Brenner D.J.: Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer. Radiology, 2004, 231: 440-445.
    • (2004) Radiology , vol.231 , pp. 440-445
    • Brenner, D.J.1
  • 3
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • Brenner D.J., Hall E.J.: Computed tomography - an increasing source of radiation exposure. N Engl J Med, 2007, 357: 2277-2284. (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 4
    • 35349026173 scopus 로고    scopus 로고
    • Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society
    • DOI 10.1148/radiol.2452070397
    • Remy-Jardin M., Pistolesi M., Goodman L.R., et al.: Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society. Radiology, 2007, 245: 315-329. (Pubitemid 47612510)
    • (2007) Radiology , vol.245 , Issue.2 , pp. 315-329
    • Remy-Jardin, M.1    Pistolesi, M.2    Goodman, L.R.3    Gefter, W.B.4    Gottschalk, A.5    Mayo, J.R.6    Sostman, H.D.7
  • 6
    • 35348977748 scopus 로고    scopus 로고
    • Image quality and radiation exposure at pulmonary CT angiography with 100- Or 120-kVp protocol: Prospective randomized study
    • Heyer C.M., Mohr P.S., Lemburg S.P., Peters S.A., Nicolas V.: Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study. Radiology, 2007, 245: 577-583.
    • (2007) Radiology , vol.245 , pp. 577-583
    • Heyer, C.M.1    Mohr, P.S.2    Lemburg, S.P.3    Peters, S.A.4    Nicolas, V.5
  • 7
    • 0035078869 scopus 로고    scopus 로고
    • Further reduction of radiation dose in helical CT for lung cancer screening using small tube current and a newly designed filter
    • DOI 10.1097/00005382-200104000-00003
    • Itoh S., Koyama S., Ikeda M., et al.: Further reduction of radiation dose in helical CT for lung cancer screening using small tube current and a newly designed filter. J Thorac Imaging, 2001, 16: 81-88. (Pubitemid 32231700)
    • (2001) Journal of Thoracic Imaging , vol.16 , Issue.2 , pp. 81-88
    • Itoh, S.1    Koyama, S.2    Ikeda, M.3    Ozaki, M.4    Sawaki, A.5    Iwano, S.6    Ishigaki, T.7
  • 8
    • 34147202921 scopus 로고    scopus 로고
    • Pulmonary emphysema: Radiation dose and section thickness at multidetector CT quantification - Comparison with macroscopic and microscopic morphometry
    • DOI 10.1148/radiol.2431060194
    • Madani A., De Maertelaer V., Zanen J., Gevenois P.A.: Pulmonary emphysema: radiation dose and section thickness at multidetector CT quantification - comparison with macroscopic and microscopic morphometry. Radiology, 2007, 243: 250-257. (Pubitemid 46579717)
    • (2007) Radiology , vol.243 , Issue.1 , pp. 250-257
    • Madani, A.1    De Maertelaer, V.2    Zanen, J.3    Gevenois, P.A.4
  • 10
    • 59649088090 scopus 로고    scopus 로고
    • Patient exposure and image quality of low-dose pulmonary computed tomography angiography: Comparison of 100- and 80-kVp protocols
    • Szucs-Farkas Z., Kurmann L., Strautz T., Patak M.A., Vock P., Schindera S.T.: Patient exposure and image quality of low-dose pulmonary computed tomography angiography: comparison of 100- and 80-kVp protocols. Invest Radiol, 2008, 43: 871-876.
    • (2008) Invest Radiol , vol.43 , pp. 871-876
    • Szucs-Farkas, Z.1    Kurmann, L.2    Strautz, T.3    Patak, M.A.4    Vock, P.5    Schindera, S.T.6
  • 11
    • 1342266221 scopus 로고    scopus 로고
    • Strategies for CT radiation dose optimization
    • Kalra M.K., Maher M.M., Toth T.L., et al.: Strategies for CT radiation dose optimization. Radiology, 2004, 230: 619-628.
    • (2004) Radiology , vol.230 , pp. 619-628
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 12
    • 4143151587 scopus 로고    scopus 로고
    • Reduced radiation dose helical chest CT: Effect on reader evaluation of structures and lung findings
    • Mayo J.R., Kim K.I., MacDonald S.L., et al.: Reduced radiation dose helical chest CT: effect on reader evaluation of structures and lung findings. Radiology, 2004, 232: 749-756.
    • (2004) Radiology , vol.232 , pp. 749-756
    • Mayo, J.R.1    Kim, K.I.2    MacDonald, S.L.3
  • 13
    • 77950619786 scopus 로고    scopus 로고
    • Collective radiation dose from MDCT: Critical review of surveys studies
    • Tack D., Gevenois P.A., eds. Berlin, Heidelberg, New York, Springer
    • Stamm G.: Collective radiation dose from MDCT: critical review of surveys studies. In: Tack D., Gevenois P.A., eds. Radiation dose from adult and pediatric multidetector computed tomography. Berlin, Heidelberg, New York, Springer, 2007, 82-97.
    • (2007) Radiation Dose from Adult and Pediatric Multidetector Computed Tomography , pp. 82-97
    • Stamm, G.1
  • 16
    • 77950606492 scopus 로고    scopus 로고
    • Automatic exposure control in multidetector-row computed tomography
    • Tack D., Gevenois P.A., eds. Berlin, Heidelberg, New York, Springer
    • Kalra M.K., Toth T.L.: Automatic exposure control in multidetector-row computed tomography. In: Tack D., Gevenois P.A., eds. Radiation dose from adult and pediatric multidetector computed tomography. Berlin, Heidelberg, New York, Springer, 2007, 117-128.
    • (2007) Radiation Dose from Adult and Pediatric Multidetector Computed Tomography , pp. 117-128
    • Kalra, M.K.1    Toth, T.L.2
  • 17
    • 0033542870 scopus 로고    scopus 로고
    • Early Lung Cancer Action Project: Overall design and findings from baseline screening
    • Henschke C.I., McCauley D.I., Yankelevitz D.F., et al.: Early Lung Cancer Action Project: overall design and findings from baseline screening. Lancet, 1999, 354: 99-105.
    • (1999) Lancet , vol.354 , pp. 99-105
    • Henschke, C.I.1    McCauley, D.I.2    Yankelevitz, D.F.3
  • 18
    • 0025799886 scopus 로고
    • Low-dose high-resolution CT of lung parenchyma
    • Zwirewich C.V., Mayo J.R., Müller N.L.: Low-dose high-resolution CT of lung parenchyma. Radiology, 1991, 180: 413-417.
    • (1991) Radiology , vol.180 , pp. 413-417
    • Zwirewich, C.V.1    Mayo, J.R.2    Müller, N.L.3
  • 19
    • 0023220989 scopus 로고
    • High-resolution CT of the lungs: An optimal approach
    • Mayo J.R., Webb W.R., Gould R., et al.: High-resolution CT of the lungs: an optimal approach. Radiology, 1987, 163: 507-510.
    • (1987) Radiology , vol.163 , pp. 507-510
    • Mayo, J.R.1    Webb, W.R.2    Gould, R.3
  • 20
    • 0037742555 scopus 로고    scopus 로고
    • Low-dose multislice CT of the thorax in follow-up of malignant lymphoma and extrapulmonary primary tumors
    • Dinkel H.P., Sonnenschein M., Hoppe H., Vock P.: Low-dose multislice CT of the thorax in follow-up of malignant lymphoma and extrapulmonary primary tumors. Eur Radiol, 2003, 13: 1241-1249. (Pubitemid 36790624)
    • (2003) European Radiology , vol.13 , Issue.6 , pp. 1241-1249
    • Dinkel, H.-P.1    Sonnenschein, M.2    Hoppe, H.3    Vock, P.4
  • 21
    • 20744455342 scopus 로고    scopus 로고
    • Comparisons of Standard-Dose and Simulated Low-Dose Multi-Detector-Row CT Pulmonary Angiography
    • Tack D., De Maertelaer V., Petit W., Scillia P., Muller P., Suess C., Gevenois P.A.: Comparisons of Standard-Dose and Simulated Low-Dose Multi-Detector-Row CT Pulmonary Angiography. Radiology, 2005, 236: 318-325.
    • (2005) Radiology , vol.236 , pp. 318-325
    • Tack, D.1    De Maertelaer, V.2    Petit, W.3    Scillia, P.4    Muller, P.5    Suess, C.6    Gevenois, P.A.7
  • 22
    • 1642389455 scopus 로고    scopus 로고
    • Low-Kilovoltage Multi-Detector Row Chest CT in Adults: Feasibility and Effect on Image Quality and Iodine Dose
    • DOI 10.1148/radiol.2311030191
    • Sigal-Cinqualbre A.B., Hennequin R., Abada H.T., Chen X., Paul J.F.: Low-kilovoltage multidetector row chest CT in adults: feasability and effect on image quality and iodine dose. Radiology, 2004, 231: 169-174. (Pubitemid 38375425)
    • (2004) Radiology , vol.231 , Issue.1 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3    Chen, X.4    Paul, J.-F.5
  • 23
    • 33846695725 scopus 로고    scopus 로고
    • CT angiography of pulmonary arteries to detect pulmonary embolism: Improvement of vascular enhancement with low kilovoltage settings
    • DOI 10.1148/radiol.2413040128
    • Schueller-Weidekamm C., Schaefer-Prokop C.M., Weber M., Herold C.J., Prokop M.: CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. Radiology, 2006, 241: 899-907. (Pubitemid 46190558)
    • (2006) Radiology , vol.241 , Issue.3 , pp. 899-907
    • Schueller-Weidekamm, C.1    Schaefer-Prokop, C.M.2    Weber, M.3    Herold, C.J.4    Prokop, M.5
  • 24
    • 33847233255 scopus 로고    scopus 로고
    • Air trapping: Comparison of standard-dose and simulated low-dose thin-section CT techniques
    • DOI 10.1148/radiol.2423060196
    • Bankier A.A., Schaefer-Prokop C., De Maertelaer V., Tack D., Jaksch P., Klepetko W., Gevenois P.A.: Air trapping: comparison of standard-dose and simulated low-dose thin-section CT techniques. Radiology, 2007, 242: 898-906. (Pubitemid 46310105)
    • (2007) Radiology , vol.242 , Issue.3 , pp. 898-906
    • Bankier, A.A.1    Schaefer-Prokop, C.2    De Maertelaer, V.3    Tack, D.4    Jaksch, P.5    Klepetko, W.6    Gevenois, P.A.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.