Addressing the stranded power problem in datacenters using storage workload characterization

Author keywords

Datacenter power provisioning; Storage characterization; Stranded power

Indexed keywords

DATA CENTERS; DATACENTER POWER PROVISIONING; POWER ALLOCATIONS; POWER CAPACITY; POWER EFFICIENCY; POWER PROBLEM; STORAGE COMPONENT; WORKLOAD CHARACTERIZATION;

EID: 77950504862     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1145/1712605.1712639     Document Type: Conference Paper
Times cited : (8)

References (17)
  • 3
    • 77950484085 scopus 로고    scopus 로고
    • SPECpower-ssj2008 http://www.spec.org/specpower/
  • 4
    • 77950507586 scopus 로고    scopus 로고
    • IOMeter, performance analysis tool. http://www.iometer.org/.
  • 5
    • 0037670375 scopus 로고    scopus 로고
    • DRPM: Dynamic speed control for power management in server class disks
    • (May. 2003)
    • S. Gurumurthi, A. Sivasubramaniam, M. Kandemir and H. Franke. 2003. DRPM: dynamic speed control for power management in server class disks. SIGARCH Comput. Archit. News 31, 2 (May. 2003), 169-181.
    • (2003) SIGARCH Comput. Archit. News , vol.31 , Issue.2 , pp. 169-181
    • Gurumurthi, S.1    Sivasubramaniam, A.2    Kandemir, M.3    Franke, H.4
  • 7
    • 65949102994 scopus 로고    scopus 로고
    • An analysis of hard drive energy consumption
    • A. Hylick, R. Sohan, A. Rice, and B. Jones. An analysis of hard drive energy consumption. In MASCOTS 2008, pages 103-112.
    • (2008) MASCOTS , pp. 103-112
    • Hylick, A.1    Sohan, R.2    Rice, A.3    Jones, B.4
  • 8
    • 84983476702 scopus 로고    scopus 로고
    • Energy management for hypervisor-based virtual machines
    • J. Stoess, C. Lang, and F. Bellosa. Energy management for hypervisor-based virtual machines. USENIX, 2007.
    • (2007) USENIX
    • Stoess, J.1    Lang, C.2    Bellosa, F.3
  • 10
    • 8344236685 scopus 로고    scopus 로고
    • Energy conservation techniques for disk array-based servers
    • E. Pinheiro and R. Bianchini. Energy conservation techniques for disk array-based servers. In ICS, 2004.
    • (2004) ICS
    • Pinheiro, E.1    Bianchini, R.2
  • 15
    • 77950510917 scopus 로고    scopus 로고
    • Seagate Barracuda® ES.2 (Server & Enterprise Storage)
    • Seagate Barracuda® ES.2 (Server & Enterprise Storage)
  • 17
    • 35348835964 scopus 로고    scopus 로고
    • Power provisioning for a warehouse-sized computer
    • (San Diego, California, USA, June 09 -13, 2007)
    • Fan, X., Weber, W., and Barroso, L. A. 2007. Power provisioning for a warehouse-sized computer. ISCA 2007 (San Diego, California, USA, June 09 - 13, 2007)
    • (2007) ISCA 2007
    • Fan, X.1    Weber, W.2    Barroso, L.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.