Volumn 25, Issue 9, 2009, Pages 138-141

Bioelectric source localization in the rat sciatic nerve: Initial assessment using an idealized nerve model

Author keywords

Bioelectric source localization; Finiteelement modeling; Multi contact nerve cuff electrode; Rat sciatic nerve; SLORETA

Indexed keywords

BIOMEDICAL ENGINEERING; ELECTRODES; FINITE ELEMENT METHOD; PROSTHETICS; RATS;

EID: 77950385237     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03889-1_38     Document Type: Conference Paper
Times cited : (4)

References (12)
  • 1
    • 3142743126 scopus 로고    scopus 로고
    • Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs
    • discussion 616-618
    • Dhillon GS, Lawrence SM., Hutchinson DT, Horch KW (2004) Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs. J. Hand Surg. 29(4):605-15; discussion 616-618
    • (2004) J. Hand Surg. , vol.29 , Issue.4 , pp. 605-615
    • Dhillon, G.S.1    Lawrence, S.M.2    Hutchinson, D.T.3    Horch, K.W.4
  • 2
    • 55749108721 scopus 로고    scopus 로고
    • On the use of longitudinal intrafascicular peripheral interfaces for the control of cybernetic hand prostheses in amputees
    • Micera S et al. (2008) On the use of longitudinal intrafascicular peripheral interfaces for the control of cybernetic hand prostheses in amputees. IEEE Trans Neural Sys Rehab Eng. 16(5):453-472.
    • (2008) IEEE Trans Neural Sys Rehab Eng , vol.16 , Issue.5 , pp. 453-472
    • Micera, S.1
  • 3
    • 0141889845 scopus 로고    scopus 로고
    • The application of implant technology for cybernetic systems
    • Warwick K et al. (2003) The application of implant technology for cybernetic systems. Arch. Neurol. 60(10):1369-1373.
    • (2003) Arch. Neurol. , vol.60 , Issue.10 , pp. 1369-1373
    • Warwick, K.1
  • 4
    • 0348147669 scopus 로고    scopus 로고
    • Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
    • Branner A, Stein RB, Fernandez E, Aoyagi Y, Normann RA (2004) Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve. IEEE Trans. Biomed. Eng. 51, 146-157.
    • (2004) IEEE Trans. Biomed. Eng. , vol.51 , pp. 146-157
    • Branner, A.1    Stein, R.B.2    Fernandez, E.3    Aoyagi, Y.4    Normann, R.A.5
  • 5
    • 0016766025 scopus 로고
    • Principles underlying new methods for chronic neural recording
    • Stein RB et al. (1975) Principles underlying new methods for chronic neural recording. Canadian J. Neurol. Sci. 2(3):235-244.
    • (1975) Canadian J. Neurol. Sci. , vol.2 , Issue.3 , pp. 235-244
    • Stein, R.B.1
  • 6
    • 0001574753 scopus 로고    scopus 로고
    • Micromachined, polyimidebased devices for flexible neural interfaces
    • Stieglitz T, Beutel H, Schuettler M, Meyer JW (2000) Micromachined, polyimidebased devices for flexible neural interfaces. Biomed. Microdev. 2:283-294.
    • (2000) Biomed. Microdev. , vol.2 , pp. 283-294
    • Stieglitz, T.1    Beutel, H.2    Schuettler, M.3    Meyer, J.W.4
  • 7
    • 23844501514 scopus 로고    scopus 로고
    • Selective recording of the canine hypoglossal nerve using a multicontact flat interface nerve electrode
    • Yoo PB, Durand DM (2005) Selective recording of the canine hypoglossal nerve using a multicontact flat interface nerve electrode. IEEE Trans. Biomed. Eng. 52(8):1461-1469.
    • (2005) IEEE Trans. Biomed. Eng. , vol.52 , Issue.8 , pp. 1461-1469
    • Yoo, P.B.1    Durand, D.M.2
  • 8
    • 60249098953 scopus 로고    scopus 로고
    • Localization of active pathways in peripheral nerves: A simulation study
    • Zariffa J, Popovic MR (2008) Localization of active pathways in peripheral nerves: a simulation study, IEEE Trans Neural Sys Rehab Eng. 17(1):53-62.
    • (2008) IEEE Trans Neural Sys Rehab Eng , vol.17 , Issue.1 , pp. 53-62
    • Zariffa, J.1    Popovic, M.R.2
  • 12
    • 0034352209 scopus 로고    scopus 로고
    • Lead-field bases for electroencephalography source imaging
    • Weinstein D, Zhukov L, Johnson C (2000) Lead-field bases for electroencephalography source imaging. Ann. Biomed. Eng. 28(9):1059-1065.
    • (2000) Ann. Biomed. Eng. , vol.28 , Issue.9 , pp. 1059-1065
    • Weinstein, D.1    Zhukov, L.2    Johnson, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.