메뉴 건너뛰기




Volumn 4, Issue 2, 2010, Pages 93-100

An 11 μ w, two-electrode transimpedance biosignal amplifier with active current feedback stabilization

Author keywords

Biosignal amplifier; Electrocardiogram; Portable physiological monitoring

Indexed keywords

ACTIVE CURRENT; AMPLIFIER SATURATION; BASELINE DRIFT; BIO-SIGNAL AMPLIFIER; BIOSIGNALS; COMMONMODE; ENSEMBLE AVERAGES; GAIN-BANDWIDTH PRODUCTS; INPUT VOLTAGES; MICROPOWER; NOISE LEVELS; PHYSIOLOGICAL MONITORING; POWER CONSUMPTION; SKIN RESISTANCE; SUPPLY RAIL; TRANSIMPEDANCE; TRANSIMPEDANCE AMPLIFIERS; TWO-ELECTRODE SYSTEMS; VOLTAGE GAIN; VOLTAGE SIGNALS;

EID: 77950301111     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2009.2032096     Document Type: Article
Times cited : (12)

References (24)
  • 2
    • 0033975221 scopus 로고    scopus 로고
    • A micropower dry-electrode ECG preamplifier
    • Feb.
    • M. J. Burke and D. T. Gleeson, "A micropower dry-electrode ECG preamplifier," IEEE Trans. Biomed. Eng., vol.47, no.2, pp. 155-162, Feb. 2000.
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , Issue.2 , pp. 155-162
    • Burke, M.J.1    Gleeson, D.T.2
  • 3
    • 2342429744 scopus 로고    scopus 로고
    • Two-electrode low supply voltage electrocardiogram signal amplifier
    • D. Dobrev, "Two-electrode low supply voltage electrocardiogram signal amplifier," Med. Biol. Eng. Comput., vol.42, pp. 272-276, 2004.
    • (2004) Med. Biol. Eng. Comput. , vol.42 , pp. 272-276
    • Dobrev, D.1
  • 4
    • 0028439453 scopus 로고
    • Amplifiers for bioelectric events: A design with a minimal number of parts
    • A. C. MettingVanRijn, A. Peper, and C. A. Grimbergen, "Amplifiers for bioelectric events: A design with a minimal number of parts," Med. Biol. Eng. Comput., vol.32, pp. 305-310, 1994.
    • (1994) Med. Biol. Eng. Comput. , vol.32 , pp. 305-310
    • MettingVanRijn, A.C.1    Peper, A.2    Grimbergen, C.A.3
  • 5
    • 34250748965 scopus 로고    scopus 로고
    • A low-power and compact analog CMOS processing chip for portable ECG recorders
    • Nov.
    • M. Shojaei-Baghini, R. K. Lal, and D. K. Sharma, "A low-power and compact analog CMOS processing chip for portable ECG recorders," in Proc. IEEE ASSCC, Nov. 2005, pp. 473-476.
    • (2005) Proc. IEEE ASSCC , pp. 473-476
    • Shojaei-Baghini, M.1    Lal, R.K.2    Sharma, D.K.3
  • 7
    • 51949105156 scopus 로고    scopus 로고
    • A 2 μ100 nV/rtHz chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials
    • Dec.
    • T. Denison, K. Consoer, W. Santa, A.-T. Avestruz, J. Cooley, and A. Kelly, "A 2 μ 100 nV/rtHz chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials," IEEE J. Solid-State Circuits, vol.42, no.12, pp. 2934-2945, Dec. 2007.
    • (2007) IEEE J. Solid-State Circuits , vol.42 , Issue.12 , pp. 2934-2945
    • Denison, T.1    Consoer, K.2    Santa, W.3    Avestruz, A.-T.4    Cooley, J.5    Kelly, A.6
  • 8
    • 51749091936 scopus 로고    scopus 로고
    • A versatile integrated circuit for the acquisition of biopotentials
    • R. R. Harrison, "A versatile integrated circuit for the acquisition of biopotentials," in Proc. IEEE CICC, 2007, pp. 115-122.
    • (2007) Proc. IEEE CICC , pp. 115-122
    • Harrison, R.R.1
  • 9
    • 29344445678 scopus 로고    scopus 로고
    • A 1-V analog CMOS front-end for detecting QRS complexes in a cardiac signal
    • I: Reg. Papers, Dec.
    • K. Lasanen and J. Kostamovaara, "A 1-V analog CMOS front-end for detecting QRS complexes in a cardiac signal," IEEE Trans. Circuits Syst. I: Reg. Papers, vol.52, no.12, pp. 2584-2594, Dec. 2005.
    • (2005) IEEE Trans. Circuits Syst. , vol.52 , Issue.12 , pp. 2584-2594
    • Lasanen, K.1    Kostamovaara, J.2
  • 10
    • 67349209167 scopus 로고    scopus 로고
    • ECG front-end design is simplified with microConverter
    • Nov.
    • E. Company-Bosch and E. Hartmann, "ECG front-end design is simplified with microConverter," Analog Dialogue, vol.37-11, pp. 1-5, Nov. 2003.
    • (2003) Analog Dialogue , vol.37 , Issue.11 , pp. 1-5
    • Company-Bosch, E.1    Hartmann, E.2
  • 11
    • 77950300672 scopus 로고    scopus 로고
    • Heart-rate and EKG monitor using the MSP430FG439
    • Sep., Figure 2
    • M. Raju, Heart-rate and EKG monitor using the MSP430FG439, Texas Instruments Appl. Rep. SLAA280A, Sep. 2007, Figure 2.
    • (2007) Texas Instruments Appl. Rep. SLAA280A
    • Raju, M.1
  • 13
    • 0032907015 scopus 로고    scopus 로고
    • EEG alpha and theta oscillations reflect cognitive and memory performance: A review and analysis
    • W. Klimesch, "EEG alpha and theta oscillations reflect cognitive and memory performance: A review and analysis," Brain Res. Rev., vol.29, no.2-3, pp. 169-195, 1999.
    • (1999) Brain Res. Rev. , vol.29 , Issue.2-3 , pp. 169-195
    • Klimesch, W.1
  • 14
    • 20744444701 scopus 로고    scopus 로고
    • Miniature ultra-low-power biopotential amplifier for potable [sic] applications
    • C.-N. Chien and F.-S. Jaw, "Miniature ultra-low-power biopotential amplifier for potable [sic] applications," Biomed. Eng.-Appl., Basis Commun., vol.17, no.2, 2005.
    • (2005) Biomed. Eng.-Appl., Basis Commun. , vol.17 , Issue.2
    • Chien, C.-N.1    Jaw, F.-S.2
  • 15
    • 51549102010 scopus 로고    scopus 로고
    • A chopper stabilized pre-amplifier for biomedical signal acquisition
    • G. A. Hanasusanto and Y. Zheng, "A chopper stabilized pre-amplifier for biomedical signal acquisition," in IEEE Int. Symp. on Integrated Circuits, 2007, pp. 200-203.
    • (2007) IEEE Int. Symp. on Integrated Circuits , pp. 200-203
    • Hanasusanto, G.A.1    Zheng, Y.2
  • 16
    • 0028439453 scopus 로고
    • Amplifiers for bioelectric events: A design with a minimal number of parts
    • A. C. MettingVanRijn, A. Peper, and C. A. Grimbergen, "Amplifiers for bioelectric events: A design with a minimal number of parts," Med. Biol. Eng. Comput., vol.32, pp. 305-310, 1994.
    • (1994) Med. Biol. Eng. Comput. , vol.32 , pp. 305-310
    • MettingVanRijn, A.C.1    Peper, A.2    Grimbergen, C.A.3
  • 17
    • 28444432367 scopus 로고    scopus 로고
    • A CMOS analog front-end IC for portable EEG/ECG monitoring applications
    • Reg. Papers, Nov.
    • K. A. Ng and P. K. Chan, "A CMOS analog front-end IC for portable EEG/ECG monitoring applications," IEEE Trans. Circuits Syst. I, Reg. Papers, vol.52, no.11, pp. 2335-2347, Nov. 2005.
    • (2005) IEEE Trans. Circuits Syst. i , vol.52 , Issue.11 , pp. 2335-2347
    • Ng, K.A.1    Chan, P.K.2
  • 18
    • 51549112952 scopus 로고    scopus 로고
    • Ultra low-power low-voltage integrated preamplifier using Class-AB op-amp for biomedical sensor application
    • A. Putra, T. H. Teo, and S. Rajinder, "Ultra low-power low-voltage integrated preamplifier using Class-AB op-amp for biomedical sensor application," in Proc. IEEE Int. Symp. Integrated Circuits, 2007, pp. 216-219.
    • (2007) Proc. IEEE Int. Symp. Integrated Circuits , pp. 216-219
    • Putra, A.1    Teo, T.H.2    Rajinder, S.3
  • 19
    • 0033638845 scopus 로고    scopus 로고
    • AC coupled three op-amp biopotential amplifier with active DC suppression
    • Dec.
    • E. M. Spinelli and M. A. Mayosky, "AC coupled three op-amp biopotential amplifier with active DC suppression," IEEE Trans. Biomed. Eng., vol.47, no.12, pp. 1616-1619, Dec. 2000.
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , Issue.12 , pp. 1616-1619
    • Spinelli, E.M.1    Mayosky, M.A.2
  • 20
    • 33745780112 scopus 로고    scopus 로고
    • A low-voltage low-noise CMOS instrumentation amplifier for portable medical monitoring systems
    • H. Wu and Y.-P. Xu, "A low-voltage low-noise CMOS instrumentation amplifier for portable medical monitoring systems," in Proc. IEEENEWCAS Conf., 2005, pp. 295-298.
    • (2005) Proc. IEEENEWCAS Conf. , pp. 295-298
    • Wu, H.1    Xu, Y.-P.2
  • 21
    • 34247325582 scopus 로고    scopus 로고
    • A 60 W 60 nV/rtHz readout front-end for portable biopotential acquisition systems
    • May
    • R. F. Yazicioglu, P. Merken, R. Puers, and C. Van Hoof, "A 60 W 60 nV/rtHz readout front-end for portable biopotential acquisition systems," IEEE J. Solid-State Circuits, vol.42, no.5, pp. 1100-1110, May 2007.
    • (2007) IEEE J. Solid-State Circuits , vol.42 , Issue.5 , pp. 1100-1110
    • Yazicioglu, R.F.1    Merken, P.2    Puers, R.3    Van Hoof, C.4
  • 22
    • 2542616918 scopus 로고    scopus 로고
    • Micro-power low-offset instrumentation amplifier IC design for biomedical system applications
    • Reg. Papers, Apr.
    • C.-J. Yen, W.-Y. Chung, and M. C. Chi, "Micro-power low-offset instrumentation amplifier IC design for biomedical system applications," IEEE Trans. Circuits Syst. I, Reg. Papers, vol.51, no.4, pp. 691-699, Apr. 2004.
    • (2004) IEEE Trans. Circuits Syst. i , vol.51 , Issue.4 , pp. 691-699
    • Yen, C.-J.1    Chung, W.-Y.2    Chi, M.C.3
  • 23
    • 0020858401 scopus 로고
    • Impedance measurement of individual skin surface electrodes
    • S. Grimnes, "Impedance measurement of individual skin surface electrodes," Med. Biol. Eng. Comput., vol.21, pp. 750-755, 1983.
    • (1983) Med. Biol. Eng. Comput. , vol.21 , pp. 750-755
    • Grimnes, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.