메뉴 건너뛰기




Volumn 4, Issue 2, 2010, Pages 101-111

Interpretations of wrist/grip operations from SEMG signals at different locations on arm

Author keywords

SEMG interpretation; Surface electromyogram (SEMG); Wrist grip operations

Indexed keywords

CAPTURING SYSTEM; FILTER ALGORITHM; FOUR-CHANNEL; FREQUENCY DOMAINS; METHOD OF MEASUREMENT; MUSCLE ACTIVITIES; MYOELECTRIC SIGNALS; PROSTHETIC HANDS; SINGLE-CHANNEL; SURFACE ELECTROMYOGRAM; TWO-CHANNEL;

EID: 77950296583     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2009.2037604     Document Type: Article
Times cited : (40)

References (22)
  • 2
    • 0028829507 scopus 로고
    • Different approaches and cultural considerations in third world prosthetics
    • [Online]. Available
    • S. Meanley, "Different approaches and cultural considerations in third world prosthetics," J. Int. Soc. Prosthetics and Orthotics vol. 19, pp. 176-180, 1995. [Online]. Available: www.oandplibrary. org/poi/pdf/1995-03- 176.pdf
    • (1995) J. Int. Soc. Prosthetics and Orthotics , vol.19 , pp. 176-180
    • Meanley, S.1
  • 3
    • 47349128252 scopus 로고    scopus 로고
    • Detection and filtering of SEMG for assessing voluntary muscle activity during FES
    • Presented at the, Bournemouth, U.K., Sep
    • T. Schauer, R. C. Salbert, N. O. Negard, and J. Raisch, "Detection and filtering of SEMG for assessing voluntary muscle activity during FES," presented at the 9th Annu. Conf. Int. FES Soc., Bournemouth, U.K., Sep. 2004.
    • (2004) 9th Annu. Conf. Int. FES Soc.
    • Schauer, T.1    Salbert, R.C.2    Negard, N.O.3    Raisch, J.4
  • 5
    • 0019732777 scopus 로고
    • Frequency parameters of the myoelectric signal as a measure of muscle conduction velocity
    • Jul.
    • F. B. Stulen and C. J. De Luca, "Frequency parameters of the myoelectric signal as a measure of muscle conduction velocity," IEEE Trans. Biomed. Eng., vol.BME-28, no.7, pp. 515-523, Jul. 1981.
    • (1981) IEEE Trans. Biomed. Eng. , vol.BME-28 , Issue.7 , pp. 515-523
    • Stulen, F.B.1    De Luca, C.J.2
  • 7
    • 0017490752 scopus 로고
    • Interpretation of myoelectric power spectra:Amodel and its applications
    • May
    • L. H. Lindstrom and R. I. Magnusson, "Interpretation of myoelectric power spectra:Amodel and its applications," in Proc. IEEE, May 1977, vol. PROC-65, no. 5, pp. 653-662.
    • (1977) Proc. IEEE , vol.PROC-65 , Issue.5 , pp. 653-662
    • Lindstrom, L.H.1    Magnusson, R.I.2
  • 8
    • 21844447139 scopus 로고    scopus 로고
    • Application of higher order statistics techniques to EMG signals to characterize the motor unit action potential
    • Jul.
    • S. Shahid, J. Walker, G. M. Lyons, C. A. Byrne, and A. V. Nene, "Application of higher order statistics techniques to EMG signals to characterize the motor unit action potential," IEEE Trans. Biomed. Eng., vol.52, no.7, pp. 1195-1205, Jul. 2005.
    • (2005) IEEE Trans. Biomed. Eng. , vol.52 , Issue.7 , pp. 1195-1205
    • Shahid, S.1    Walker, J.2    Lyons, G.M.3    Byrne, C.A.4    Nene, A.V.5
  • 9
    • 0016506177 scopus 로고
    • An analysis of the electromyogram by fourier, simulation and experimental techniques
    • May
    • G. C. Agarwal and G. L. Gottlieb, "An analysis of the electromyogram by fourier, simulation and experimental techniques," IEEE Trans. Biomed. Eng., vol.BME-22, no.3, pp. 225-229, May 1975.
    • (1975) IEEE Trans. Biomed. Eng. , vol.BME-22 , Issue.3 , pp. 225-229
    • Agarwal, G.C.1    Gottlieb, G.L.2
  • 10
    • 0030296976 scopus 로고    scopus 로고
    • Analysis of myoelectric signals recorded during dynamic contractions
    • Nov./Dec.
    • P. Bonato, G. Gagliati, and M. Knaflitz, "Analysis of myoelectric signals recorded during dynamic contractions," IEEE Eng. Med. Biol. Mag., vol.15, no.6, pp. 102-111, Nov./Dec. 1996.
    • (1996) IEEE Eng. Med. Biol. Mag. , vol.15 , Issue.6 , pp. 102-111
    • Bonato, P.1    Gagliati, G.2    Knaflitz, M.3
  • 13
    • 77950299796 scopus 로고    scopus 로고
    • [Online]. Available
    • [Online]. Available: http://www.geocities.com/jrh-iii/acupressure/ acupoints.html-Acupoint of arm
  • 14
    • 34247369307 scopus 로고    scopus 로고
    • Modified adaptive resonance theory based control strategy for SEMG operated prosthesis for below-elbow amputee
    • May/Jun.
    • A. S. Arora, "Modified adaptive resonance theory based control strategy for SEMG operated prosthesis for below-elbow amputee," J. Med. Eng. Technol., vol.31, no.3, pp. 191-201, May/Jun. 2007.
    • (2007) J. Med. Eng. Technol. , vol.31 , Issue.3 , pp. 191-201
    • Arora, A.S.1
  • 15
    • 75049085959 scopus 로고    scopus 로고
    • Study of issues in the development of surface EMG controlled human hand
    • 10.1007/s10856-008-3492-3494
    • H. S. Ryait, A. S. Arora, and R. Agarwal, "Study of issues in the development of surface EMG controlled human hand," J. Mater. Sci.: Materials in Medicine, 10.1007/s10856-008-3492-3494
    • J. Mater. Sci.: Materials in Medicine
    • Ryait, H.S.1    Arora, A.S.2    Agarwal, R.3
  • 17
    • 0026243164 scopus 로고
    • Computer analysis of the myoelectric signal
    • 48-58, Oct.
    • M. Knaflitz and G. Balestra, "Computer analysis of the myoelectric signal," IEEE Micro., vol.11, no.5, pp. 12-15, 48-58, Oct. 1991.
    • (1991) IEEE Micro , vol.11 , Issue.5 , pp. 12-15
    • Knaflitz, M.1    Balestra, G.2
  • 18
    • 77950297217 scopus 로고    scopus 로고
    • Filter design in thirty seconds
    • Texas Instruments, Dec., SLOA093
    • Texas Instruments, "Filter design in thirty seconds," Dec. 2001, Appl. Rep., SLOA093.
    • (2001) Appl. Rep.
  • 19
    • 33645224070 scopus 로고    scopus 로고
    • Techniques of EMG signal analysis: Detection, processing, classification and applications
    • Online, Mar
    • M. B. I. Reaz, M. S. Hussain1, and F. Mohd-Yasin, "Techniques of EMG signal analysis: Detection, processing, classification and applications," in Proc. Biol, Online, Mar. 23, 2006, p. 11.
    • (2006) Proc. Biol , vol.23 , pp. 11
    • Reaz, M.B.I.1    Hussain, M.S.2    Mohd-Yasin, F.3
  • 20
    • 50049106818 scopus 로고    scopus 로고
    • Neuro-fuzzy surfaceEMGpattern recognition for multifunctional hand prosthesis control
    • Jun.
    • M. Khezri, M. Jahed, and N. Sadati, "Neuro-fuzzy surfaceEMGpattern recognition for multifunctional hand prosthesis control," in Proc. Int. Symp. Industrial Electronics, Jun. 2007, vol.4-7, pp. 269-274.
    • (2007) Proc. Int. Symp. Industrial Electronics , vol.4-7 , pp. 269-274
    • Khezri, M.1    Jahed, M.2    Sadati, N.3
  • 21
    • 77950300504 scopus 로고    scopus 로고
    • Released Dec. 31, [Online]. Available
    • StatistiXL 1.8 (Free), Released Dec. 31, 2007. [Online]. Available: http://www.statistixl.com
    • (2007)
  • 22
    • 77950301329 scopus 로고    scopus 로고
    • PCA: main objectives and properties, [Online]. Available
    • PCA: main objectives and properties, 2009. [Online]. Available: http:// taxonomy.delrieu.org/methods-pca.php
    • (2009)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.