-
2
-
-
11844291920
-
Diabetic nephropathy: Diagnosis, prevention, and treatment
-
Gross, J.L.; de Azevedo, M.J.; Silveiro, S.P.; Canani, L.H.; Caramori, M.L.; Zelmanovitz, T. Diabetic nephropathy: diagnosis, prevention, and treatment. Diabetes Care 2005, 28, 164-176.
-
(2005)
Diabetes Care
, vol.28
, pp. 164-176
-
-
Gross, J.L.1
de Azevedo, M.J.2
Silveiro, S.P.3
Canani, L.H.4
Caramori, M.L.5
Zelmanovitz, T.6
-
3
-
-
0000656517
-
Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
-
Sacks, D.B.; Bruns, D.E.; Goldstein, D.E.; Maclaren, N.K.; McDonald, J.M.; Parrott, M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Diabetes Care 2002, 25, 750-786.
-
(2002)
Diabetes Care
, vol.25
, pp. 750-786
-
-
Sacks, D.B.1
Bruns, D.E.2
Goldstein, D.E.3
Maclaren, N.K.4
McDonald, J.M.5
Parrott, M.6
-
4
-
-
0018166150
-
Radioimmunoassay for urinary albumin
-
Woo, J.; Floyd, M.; Cannon, D.C.; Kahan, B. Radioimmunoassay for urinary albumin. Clin. Chem. 1978, 24, 1464-1467.
-
(1978)
Clin. Chem
, vol.24
, pp. 1464-1467
-
-
Woo, J.1
Floyd, M.2
Cannon, D.C.3
Kahan, B.4
-
5
-
-
0031029775
-
Development and validation of a particle-enhanced turbidimetric inhibition assay for urine albumin on the Dade aca analyzer
-
Thakkar, H.; Newman, D.J.; Holownia, P.; Davey, C.L.; Wang, C.C.; Lloyd, J.; Craig, A.R.; Price, C.P. Development and validation of a particle-enhanced turbidimetric inhibition assay for urine albumin on the Dade aca analyzer. Clin. Chem. 1997, 43, 109-113.
-
(1997)
Clin. Chem
, vol.43
, pp. 109-113
-
-
Thakkar, H.1
Newman, D.J.2
Holownia, P.3
Davey, C.L.4
Wang, C.C.5
Lloyd, J.6
Craig, A.R.7
Price, C.P.8
-
6
-
-
0023780638
-
Measurement of albumin in urine by end-point immunonephelometry
-
Stamp, R.J. Measurement of albumin in urine by end-point immunonephelometry. Ann. Clin. Biochem. 1988, 25(Pt 4), 442-443.
-
(1988)
Ann. Clin. Biochem
, vol.25
, Issue.Pt 4
, pp. 442-443
-
-
Stamp, R.J.1
-
7
-
-
18744373899
-
Microplate ELISA for urine microalbumin: Reference values and results in patients with type 2 diabetes and cardiovascular disease
-
Wu, T.L.; Chang, P.Y.; Li, C.C.; Tsao, K.C.; Sun, C.F.; Wu, J.T. Microplate ELISA for urine microalbumin: Reference values and results in patients with type 2 diabetes and cardiovascular disease. Ann. Clin. Lab. Sci. 2005, 35, 149-154.
-
(2005)
Ann. Clin. Lab. Sci
, vol.35
, pp. 149-154
-
-
Wu, T.L.1
Chang, P.Y.2
Li, C.C.3
Tsao, K.C.4
Sun, C.F.5
Wu, J.T.6
-
8
-
-
0034034743
-
Evaluation of a new fluorescent dye method to measure urinary albumin in lieu of urinary total protein
-
Pegoraro, A.A.; Peracha, W.; Hasnain, M.; Ranginwala, N.; Shaykh, M.; Singh, A.K.; Arruda, J.A.L.; Dunea, G. Evaluation of a new fluorescent dye method to measure urinary albumin in lieu of urinary total protein. Am. J. Kidney Dis. 2000, 35, 739-744.
-
(2000)
Am. J. Kidney Dis
, vol.35
, pp. 739-744
-
-
Pegoraro, A.A.1
Peracha, W.2
Hasnain, M.3
Ranginwala, N.4
Shaykh, M.5
Singh, A.K.6
Arruda, J.A.L.7
Dunea, G.8
-
9
-
-
0028957203
-
Clinical diagnostics opportunities for biosensors and bioelectronics
-
Connolly, P. Clinical diagnostics opportunities for biosensors and bioelectronics. Biosens. Bioelectron. 1995, 10, 1-6.
-
(1995)
Biosens. Bioelectron
, vol.10
, pp. 1-6
-
-
Connolly, P.1
-
10
-
-
57849163084
-
Capillary-based microfluidic analysis systems
-
Fang, Q.; Sun, M.; Huang, Y.Z. Capillary-based microfluidic analysis systems. Anal. Bioanal. Chem. 2009, 393, 63-66.
-
(2009)
Anal. Bioanal. Chem
, vol.393
, pp. 63-66
-
-
Fang, Q.1
Sun, M.2
Huang, Y.Z.3
-
11
-
-
20844439856
-
Improving agglutination tests by working in microfluidic channels
-
Degre, G.; Brunet, E.; Dodge, A.; Tabeling, P. Improving agglutination tests by working in microfluidic channels. Lab Chip 2005, 5, 691-694.
-
(2005)
Lab Chip
, vol.5
, pp. 691-694
-
-
Degre, G.1
Brunet, E.2
Dodge, A.3
Tabeling, P.4
-
12
-
-
39549094018
-
Current development in microfluidic immunosensing chip
-
Henares, T.G.; Mizutani, F.; Hisamoto, H. Current development in microfluidic immunosensing chip. Anal. Chim. Acta 2008, 611, 17-30.
-
(2008)
Anal. Chim. Acta
, vol.611
, pp. 17-30
-
-
Henares, T.G.1
Mizutani, F.2
Hisamoto, H.3
-
13
-
-
33847381014
-
Latex immunoagglutination assay for a vasculitis marker in a microfluidic device using static light scattering detection
-
Lucas, L.J.; Han, J.-H.; Chesler, J.; Yoon, J.-Y. Latex immunoagglutination assay for a vasculitis marker in a microfluidic device using static light scattering detection. Biosens. Bioelectron. 2007, 22, 2216-2222.
-
(2007)
Biosens. Bioelectron
, vol.22
, pp. 2216-2222
-
-
Lucas, L.J.1
Han, J.-H.2
Chesler, J.3
Yoon, J.-Y.4
-
14
-
-
39049118856
-
Integrated microfluidic systems with an immunosensor modified with carbon nanotubes for detection of prostate specific antigen (PSA) in human serum samples
-
Panini, N.V.; Messina, G.A.; Salinas, E.; Fernández, H.; Raba, J. Integrated microfluidic systems with an immunosensor modified with carbon nanotubes for detection of prostate specific antigen (PSA) in human serum samples. Biosens. Bioelectron. 2008, 23, 1145-1151.
-
(2008)
Biosens. Bioelectron
, vol.23
, pp. 1145-1151
-
-
Panini, N.V.1
Messina, G.A.2
Salinas, E.3
Fernández, H.4
Raba, J.5
-
15
-
-
43649100158
-
Microfluidic biochip for chemiluminescent detection of allergen-specific antibodies
-
Heyries, K.A.; Loughran, M.G.; Hoffmann, D.; Homsy, A.; Blum, L.J.; Marquette, C.A. Microfluidic biochip for chemiluminescent detection of allergen-specific antibodies. Biosens. Bioelectron. 2008, 23, 1812-1818.
-
(2008)
Biosens. Bioelectron
, vol.23
, pp. 1812-1818
-
-
Heyries, K.A.1
Loughran, M.G.2
Hoffmann, D.3
Homsy, A.4
Blum, L.J.5
Marquette, C.A.6
-
16
-
-
33646546738
-
Unconventional detection methods for microfluidic devices
-
Viskari, P.J.; Landers, J.P. Unconventional detection methods for microfluidic devices. Electrophoresis 2006, 27, 1797-1810.
-
(2006)
Electrophoresis
, vol.27
, pp. 1797-1810
-
-
Viskari, P.J.1
Landers, J.P.2
-
17
-
-
66149156128
-
Integrated microfluidic immunoassay for the rapid determination of clenbuterol
-
Kong, J.; Jiang, L.; Su, X.; Qin, J.; Du, Y.; Lin, B. Integrated microfluidic immunoassay for the rapid determination of clenbuterol. Lab Chip 2009, 9, 1541-1547.
-
(2009)
Lab Chip
, vol.9
, pp. 1541-1547
-
-
Kong, J.1
Jiang, L.2
Su, X.3
Qin, J.4
Du, Y.5
Lin, B.6
-
18
-
-
22144498400
-
PDMS microfludic device for optical detection of protein immunoassay using gold nanoparticles
-
Luo, C.; Fu, Q.; Li, H.; Xu, L.; Sun, M.; Ouyang, Q.; Chen, Y.; Ji, H. PDMS microfludic device for optical detection of protein immunoassay using gold nanoparticles. Lab Chip 2005, 5, 726-729.
-
(2005)
Lab Chip
, vol.5
, pp. 726-729
-
-
Luo, C.1
Fu, Q.2
Li, H.3
Xu, L.4
Sun, M.5
Ouyang, Q.6
Chen, Y.7
Ji, H.8
-
19
-
-
0347134477
-
Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies
-
Sia, S.K.; Whitesides, G.M. Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies. Electrophoresis 2003, 24, 3563-3576.
-
(2003)
Electrophoresis
, vol.24
, pp. 3563-3576
-
-
Sia, S.K.1
Whitesides, G.M.2
-
20
-
-
2342574189
-
Rapid fabrication of a poly(dimethylsiloxane) microfluidic capillary gel electrophoresis system utilizing high precision machining
-
Zhao, D.S.; Roy, B.; McCormick, M.T.; Kuhr, W.G.; Brazill, S.A. Rapid fabrication of a poly(dimethylsiloxane) microfluidic capillary gel electrophoresis system utilizing high precision machining. Lab Chip 2003, 3, 93-99.
-
(2003)
Lab Chip
, vol.3
, pp. 93-99
-
-
Zhao, D.S.1
Roy, B.2
McCormick, M.T.3
Kuhr, W.G.4
Brazill, S.A.5
-
21
-
-
33846548080
-
The enhanced diffusional mixing for latex immunoagglutination assay in a microfluidic device
-
Han, J.H.; Kim, K.S.; Yoon, J.Y. The enhanced diffusional mixing for latex immunoagglutination assay in a microfluidic device. Anal. Chim. Acta 2007, 584, 252-259.
-
(2007)
Anal. Chim. Acta
, vol.584
, pp. 252-259
-
-
Han, J.H.1
Kim, K.S.2
Yoon, J.Y.3
-
22
-
-
0019518375
-
Determination of beta 2-microglobulin in human urine and serum by latex immunoassay
-
Bernard, A.M.; Vyskocil, A.; Lauwerys, R.R. Determination of beta 2-microglobulin in human urine and serum by latex immunoassay. Clin. Chem. 1981, 27, 832-837.
-
(1981)
Clin. Chem
, vol.27
, pp. 832-837
-
-
Bernard, A.M.1
Vyskocil, A.2
Lauwerys, R.R.3
-
23
-
-
77950207837
-
-
BIOTOL, Butterworth-Heinemann Ltd: Oxford, UK
-
BIOTOL; Currell, B.C.; Dam-Mieras, R.C.E. Antigen-Antibody Reaction, Technological Applications of Immunochemicals; Butterworth-Heinemann Ltd: Oxford, UK, 1994.
-
(1994)
Antigen-antibody Reaction, Technological Applications of Immunochemicals
-
-
Currell, B.C.1
Dam-Mieras, R.C.E.2
-
24
-
-
57649205738
-
Backscattering particle immunoassays in wire-guide droplet manipulations
-
Yoon, J.Y.; You, D.J. Backscattering particle immunoassays in wire-guide droplet manipulations. J. Biol. Eng. 2008, 2, 15.
-
(2008)
J. Biol. Eng
, vol.2
, pp. 15
-
-
Yoon, J.Y.1
You, D.J.2
-
25
-
-
33645799065
-
Analytical validation of an HPLC assay for urinary albumin
-
Contois, J.H.; Hartigan, C.; Rao, L.V.; Snyder, L.M.; Thompson, M.J. Analytical validation of an HPLC assay for urinary albumin. Clin. Chim. Acta 2006, 367, 150-155.
-
(2006)
Clin. Chim. Acta
, vol.367
, pp. 150-155
-
-
Contois, J.H.1
Hartigan, C.2
Rao, L.V.3
Snyder, L.M.4
Thompson, M.J.5
-
26
-
-
0346023033
-
Differences in urinary albumin detected by four immunoassays and high-performance liquid chromatography
-
Comper, W.D.; Jerums, G.; Osicka, T.M. Differences in urinary albumin detected by four immunoassays and high-performance liquid chromatography. Clin. Biochem. 2004, 37, 105-111.
-
(2004)
Clin. Biochem
, vol.37
, pp. 105-111
-
-
Comper, W.D.1
Jerums, G.2
Osicka, T.M.3
-
27
-
-
84947534098
-
Proposals for the description and masurement of carry-over effects in clinical chemistry
-
Haeckel, R. Proposals for the description and masurement of carry-over effects in clinical chemistry. Pure Appl. Chem. 1991, 63, 301-306.
-
(1991)
Pure Appl. Chem
, vol.63
, pp. 301-306
-
-
Haeckel, R.1
-
28
-
-
0032884749
-
Measuring agreement in method comparison studies
-
Bland, J.M.; Altman, D.G. Measuring agreement in method comparison studies. Stat. Methods Med. Res. 1999, 8, 135-160.
-
(1999)
Stat. Methods Med. Res
, vol.8
, pp. 135-160
-
-
Bland, J.M.1
Altman, D.G.2
-
29
-
-
0021045350
-
A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, Part I
-
Bablok, P.H. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, Part I. J. Clin. Chem. Clin. Biochem. 1983, 21, 709-720.
-
(1983)
J. Clin. Chem. Clin. Biochem
, vol.21
, pp. 709-720
-
-
Bablok, P.H.1
-
30
-
-
67649382950
-
Portable microfluidic system for determination of urinary creatinine
-
Songjaroen, T.; Maturos, T.; Sappat, A.; Tuantranont, A.; Laiwattanapaisal, W. Portable microfluidic system for determination of urinary creatinine. Anal. Chim. Acta 2009, 647, 78-83.
-
(2009)
Anal. Chim. Acta
, vol.647
, pp. 78-83
-
-
Songjaroen, T.1
Maturos, T.2
Sappat, A.3
Tuantranont, A.4
Laiwattanapaisal, W.5
-
31
-
-
39649116679
-
Single cell level detection of Escherichia coli in microfluidic device
-
Han, J.-H.; Heinze, B.C.; Yoon, J.-Y. Single cell level detection of Escherichia coli in microfluidic device. Biosens. Bioelectron. 2008, 23, 1303-1306.
-
(2008)
Biosens. Bioelectron
, vol.23
, pp. 1303-1306
-
-
Han, J.-H.1
Heinze, B.C.2
Yoon, J.-Y.3
-
32
-
-
64549164505
-
Microfluidic immunosensor for rapid and sensitive detection of bovine viral diarrhea virus
-
Heinze, B.C.; Song, J.-Y.; Lee, C.-H.; Najam, A.; Yoon, J.-Y. Microfluidic immunosensor for rapid and sensitive detection of bovine viral diarrhea virus. Sens. Actuat. B-Chem. 2009, 138, 491-496.
-
(2009)
Sens. Actuat. B-chem
, vol.138
, pp. 491-496
-
-
Heinze, B.C.1
Song, J.-Y.2
Lee, C.-H.3
Najam, A.4
Yoon, J.-Y.5
|