메뉴 건너뛰기




Volumn 23, Issue 1, 2010, Pages 100-104

Uncommon complications of long-term hemodialysis catheters: Adhesion, migration, and perforation by the catheter tip

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CASE REPORT; CATHETERIZATION; EQUIPMENT; FEMALE; FOREIGN BODY; HUMAN; INSTRUMENTATION; MALE; MIDDLE AGED; RENAL REPLACEMENT THERAPY; TIME;

EID: 77950272318     PISSN: 08940959     EISSN: 1525139X     Source Type: Journal    
DOI: 10.1111/j.1525-139X.2009.00681.x     Document Type: Article
Times cited : (21)

References (24)
  • 2
    • 63049121872 scopus 로고    scopus 로고
    • Median sternotomy for an unexpected complication of permanent hemodialysis catheters: " stuck catheter."
    • Akgun S, AK K, Tugrular S, Civelek A, Isbir C, Arsan S. Median sternotomy for an unexpected complication of permanent hemodialysis catheters: " stuck catheter." VASA 2008, 37:293-296.
    • (2008) VASA , vol.37 , pp. 293-296
    • Akgun, S.1    AK, K.2    Tugrular, S.3    Civelek, A.4    Isbir, C.5    Arsan, S.6
  • 3
    • 23944478637 scopus 로고    scopus 로고
    • Tethered hemodialysis catheter with retained portions in central vein and right atrium on attempted removal
    • Thein H, Ratanjee SK. Tethered hemodialysis catheter with retained portions in central vein and right atrium on attempted removal. AJKD 2005, 46:E35-E39.
    • (2005) AJKD , vol.46
    • Thein, H.1    Ratanjee, S.K.2
  • 4
    • 0028097301 scopus 로고
    • Bronchial erosion by an indwelling central venous catheter
    • Caron NR, Demmy TL, Curtis JJ. Bronchial erosion by an indwelling central venous catheter. Chest 1994, 106:1917-1918.
    • (1994) Chest , vol.106 , pp. 1917-1918
    • Caron, N.R.1    Demmy, T.L.2    Curtis, J.J.3
  • 5
    • 23844557504 scopus 로고    scopus 로고
    • Caval perforation with bronchial communication: a rare complication of long term venous access
    • Johnson LA, Alikan MA, Mehta P, Culp WC. Caval perforation with bronchial communication: a rare complication of long term venous access. J Vasc Interv Radiol 2005, 16:1149-1152.
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 1149-1152
    • Johnson, L.A.1    Alikan, M.A.2    Mehta, P.3    Culp, W.C.4
  • 7
    • 0025101089 scopus 로고
    • Venobronchial fistula: a complication associated with central venous catheterization for chemotherapy
    • Beauregard JF, Matsumoto AH, Paul MG, Holt RW. Venobronchial fistula: a complication associated with central venous catheterization for chemotherapy. Cathet Cardiovasc Diagn 1990, 19:49-52.
    • (1990) Cathet Cardiovasc Diagn , vol.19 , pp. 49-52
    • Beauregard, J.F.1    Matsumoto, A.H.2    Paul, M.G.3    Holt, R.W.4
  • 10
    • 33244463057 scopus 로고    scopus 로고
    • The carina as a radiological landmark for central venous catheter tip position
    • Stonelake PA, Bodenham AR. The carina as a radiological landmark for central venous catheter tip position. Br J Anaesth 2006, 96:335-340.
    • (2006) Br J Anaesth , vol.96 , pp. 335-340
    • Stonelake, P.A.1    Bodenham, A.R.2
  • 11
    • 0026741305 scopus 로고
    • Vascular erosions by central venous catheters clinical features and outcome
    • Duntley P, Siever J, Korwes ML, Harpel K, Heffner JE. Vascular erosions by central venous catheters clinical features and outcome. Chest 1992, 101:1633-1638.
    • (1992) Chest , vol.101 , pp. 1633-1638
    • Duntley, P.1    Siever, J.2    Korwes, M.L.3    Harpel, K.4    Heffner, J.E.5
  • 12
    • 77950252295 scopus 로고    scopus 로고
    • Cardiac tamponade caused by central venous catheter perforation of the heart: clinical suspicion can save a patient
    • Choudhury M, Saxena N, Kale SC. Cardiac tamponade caused by central venous catheter perforation of the heart: clinical suspicion can save a patient. Indian J Anaesth 2003, 47:218-219.
    • (2003) Indian J Anaesth , vol.47 , pp. 218-219
    • Choudhury, M.1    Saxena, N.2    Kale, S.C.3
  • 14
    • 0033916677 scopus 로고    scopus 로고
    • Thrombus on indwelling central venous catheters: the histopathology of " fibrin sheaths."
    • Suojanen JN, Brophy DP, Nasser I. Thrombus on indwelling central venous catheters: the histopathology of " fibrin sheaths." Cardiovasc Intervent Radiol 2000, 23:194-197.
    • (2000) Cardiovasc Intervent Radiol , vol.23 , pp. 194-197
    • Suojanen, J.N.1    Brophy, D.P.2    Nasser, I.3
  • 15
    • 0141705179 scopus 로고    scopus 로고
    • Histologic changes in the human vein wall adjacent to indwelling central venous catheters
    • Forauer AR, Theoharis C. Histologic changes in the human vein wall adjacent to indwelling central venous catheters. J Vasc Interv Radiol 2003, 14:1163-1168.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 1163-1168
    • Forauer, A.R.1    Theoharis, C.2
  • 17
    • 33847651675 scopus 로고    scopus 로고
    • Retained central venous hemodialysis access catheters (Letter)
    • Liu T, Hanna N, Summers D. Retained central venous hemodialysis access catheters (Letter). Nephrol Dial Transplant 2007, 22:960-961.
    • (2007) Nephrol Dial Transplant , vol.22 , pp. 960-961
    • Liu, T.1    Hanna, N.2    Summers, D.3
  • 18
    • 0035723164 scopus 로고    scopus 로고
    • Hemodialysis central venous catheter tip fracture with embolization into the pulmonary artery
    • Chawla LS, Chegini S, Thomas JW, Guzman NJ. Hemodialysis central venous catheter tip fracture with embolization into the pulmonary artery. AJKD 2001, 38:1311-1315.
    • (2001) AJKD , vol.38 , pp. 1311-1315
    • Chawla, L.S.1    Chegini, S.2    Thomas, J.W.3    Guzman, N.J.4
  • 19
    • 0034094362 scopus 로고    scopus 로고
    • Retrieval of an IV catheter fragment from the pulmonary artery 11 years after an embolization
    • Thanigaraj S, Panneerselvam A, Yanos J. Retrieval of an IV catheter fragment from the pulmonary artery 11 years after an embolization. Chest 2000, 117:1209-1211.
    • (2000) Chest , vol.117 , pp. 1209-1211
    • Thanigaraj, S.1    Panneerselvam, A.2    Yanos, J.3
  • 20
    • 85061073993 scopus 로고    scopus 로고
    • Pulmonary embolism due to catheter fracture from a tunneled dialysis catheter
    • Sagar V, Lederer E. Pulmonary embolism due to catheter fracture from a tunneled dialysis catheter. AJKD 2004, 43:E5.
    • (2004) AJKD , vol.43
    • Sagar, V.1    Lederer, E.2
  • 21
    • 0347711976 scopus 로고    scopus 로고
    • A scanning electron microscopy analysis of a spontaneous hemodialysis catheter fracture
    • Weijmer MC, Kars SM, ter Wee PM. A scanning electron microscopy analysis of a spontaneous hemodialysis catheter fracture. AJKD 2001, 38:858-861.
    • (2001) AJKD , vol.38 , pp. 858-861
    • Weijmer, M.C.1    Kars, S.M.2    ter Wee, P.M.3
  • 23
    • 2342560536 scopus 로고    scopus 로고
    • Delayed migration of a catheter fragment from the left to the right pulmonary artery
    • Nellore A, Trerotola SO. Delayed migration of a catheter fragment from the left to the right pulmonary artery. J Vasc Interv Radiol 2004, 15:497-499.
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 497-499
    • Nellore, A.1    Trerotola, S.O.2
  • 24
    • 0016312575 scopus 로고
    • Intravenous catheter emboli: experience with twenty cases and collective review
    • Richardson JD, Grover FL, Trinkle JK. Intravenous catheter emboli: experience with twenty cases and collective review. Am J Surg 1974, 128:722-727.
    • (1974) Am J Surg , vol.128 , pp. 722-727
    • Richardson, J.D.1    Grover, F.L.2    Trinkle, J.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.