Volumn 36, Issue 2, 2010, Pages 291-295

Difference of fetal heart rate accelerations based on 10 and 15 beats per minute

Author keywords

Computerized analysis; Fetal heart rate acceleration; Fetal heart rate definition; Linear regression model; Non stress test

Indexed keywords

ARTICLE; COMPUTER ANALYSIS; CONTROLLED STUDY; FETUS; FETUS HEART RATE; FETUS MONITORING; GESTATIONAL AGE; HEART RATE VARIABILITY; HUMAN; PREGNANT WOMAN;

EID: 77950201749     PISSN: 13418076     EISSN: 14470756     Source Type: Journal    
DOI: 10.1111/j.1447-0756.2009.01150.x     Document Type: Article
Times cited : (6)

References (13)
  • 1
    • 0031474793 scopus 로고    scopus 로고
    • Electronic fetal heart rate monitoring: Research guideline for interpretation
    • National Institute of Child and Human Development Research Planning Workshop.
    • National Institute of Child and Human Development Research Planning Workshop. Electronic fetal heart rate monitoring: research guideline for interpretation. Am J Obstet Gynecol 1997 177 : 1385 1390.
    • (1997) Am J Obstet Gynecol , vol.177 , pp. 1385-1390
  • 2
    • 55949106755 scopus 로고    scopus 로고
    • The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: Update on definitions, interpretation, and research guidelines
    • Macones GA, Hankins GD, Spong CY, Hauth J, Moore T. The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: update on definitions, interpretation, and research guidelines. Obstet Gynecol 2008 112 : 661 666.
    • (2008) Obstet Gynecol , vol.112 , pp. 661-666
    • MacOnes, G.A.1    Hankins, G.D.2    Spong, C.Y.3    Hauth, J.4    Moore, T.5
  • 4
    • 0023226057 scopus 로고
    • Patterns of human fetal heart rate accelerations from 26 weeks to term
    • Gagnon R, Campbell K, Hunse C, Patrick J. Patterns of human fetal heart rate accelerations from 26 weeks to term. Am J Obstet Gynecol 1987 157 : 743 748.
    • (1987) Am J Obstet Gynecol , vol.157 , pp. 743-748
    • Gagnon, R.1    Campbell, K.2    Hunse, C.3    Patrick, J.4
  • 5
    • 35148890328 scopus 로고    scopus 로고
    • National Institute for Health and Clinical Excellence. Nice Clinical Guideline 55. London. NICE
    • National Institute for Health and Clinical Excellence. Intrapartum Care - Care of Healthy Women and Their Babies during Childbirth. Nice Clinical Guideline 55. London : NICE, 2007 44 45.
    • (2007) Intrapartum Care - Care of Healthy Women and Their Babies during Childbirth. , pp. 44-45
  • 7
    • 15144361313 scopus 로고
    • Antepartum cardiotocography
    • Chamberlain, G. ed.). Oxford. Blackwell Scientific Publications
    • Spencer JAD. Antepartum cardiotocography. In : Chamberlain G (ed.). Modern Antenatal Care of the Fetus. Oxford : Blackwell Scientific Publications, 1990 163 188.
    • (1990) Modern Antenatal Care of the Fetus , pp. 163-188
    • Spencer, J.A.D.1
  • 8
    • 0034133452 scopus 로고    scopus 로고
    • ACOG practice bulletin. Antepartum fetal surveillance. Number 9, October 1999. Clinical management guidelines for obstetrician-gynecologists
    • American College of Obstetricians and Gynecologists.
    • American College of Obstetricians and Gynecologists. ACOG practice bulletin. Antepartum fetal surveillance. Number 9, October 1999. Clinical management guidelines for obstetrician-gynecologists. Int J Gynaecol Obstet 2000 68 : 175 185.
    • (2000) Int J Gynaecol Obstet , vol.68 , pp. 175-185
  • 10
    • 34247895510 scopus 로고    scopus 로고
    • Chaotic indices and canonical ensemble of heart rate patterns in small-for-gestational age fetuses
    • Hoh JK, Park YS, Cha KJ et al. Chaotic indices and canonical ensemble of heart rate patterns in small-for-gestational age fetuses. J Perinat Med 2007 35 : 210 216.
    • (2007) J Perinat Med , vol.35 , pp. 210-216
    • Hoh, J.K.1    Park, Y.S.2    Cha, K.J.3
  • 11
    • 0021949081 scopus 로고
    • Improvements in the registration and analysis of fetal heart records at the bedside
    • Dawes GS, Redman CWG, Smith JH. Improvements in the registration and analysis of fetal heart records at the bedside. Br J Obstet Gynecol 1985 92 : 317 318.
    • (1985) Br J Obstet Gynecol , vol.92 , pp. 317-318
    • Dawes, G.S.1    Redman, C.W.G.2    Smith, J.H.3
  • 12
    • 0022411763 scopus 로고
    • The relationship of the nonstress test to gestational age
    • Druzin ML, Fox A, Kogut E, Carlson C. The relationship of the nonstress test to gestational age. Am J Obstet Gynecol 1985 153 : 386 389.
    • (1985) Am J Obstet Gynecol , vol.153 , pp. 386-389
    • Druzin, M.L.1    Fox, A.2    Kogut, E.3    Carlson, C.4
  • 13
    • 0022354511 scopus 로고
    • A prospective analysis of the influence of gestational age on the baseline fetal heart rate and reactivity in a low-risk population
    • Smith CV, Phelan JP, Paul RH. A prospective analysis of the influence of gestational age on the baseline fetal heart rate and reactivity in a low-risk population. Am J Obstet Gynecol 1985 153 : 780 782.
    • (1985) Am J Obstet Gynecol , vol.153 , pp. 780-782
    • Smith, C.V.1    Phelan, J.P.2    Paul, R.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.