메뉴 건너뛰기




Volumn 25, Issue 4, 2009, Pages 363-366

A 3D simulation system for hip joint replacement planning

Author keywords

Computational steering; Finite elements; Implant planning; Orthopedics; Stress visualization

Indexed keywords

BIOINFORMATICS; BIOMECHANICS; BIOMEDICAL ENGINEERING; BIOPHYSICS; FINITE ELEMENT METHOD; HIP PROSTHESES; MEDICAL PHYSICS; ORTHOPEDICS; THREE DIMENSIONAL COMPUTER GRAPHICS; VISUALIZATION;

EID: 77950172517     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03882-2_96     Document Type: Conference Paper
Times cited : (7)

References (11)
  • 2
    • 0036367932 scopus 로고    scopus 로고
    • The influence on strain shielding of material stiffness of press-fit femoral components
    • J. A. Simões and M. A. Vaz (2002) The influence on strain shielding of material stiffness of press-fit femoral components. Journal of Engineering in Medicine, 216(5):341-346.
    • (2002) Journal of Engineering in Medicine , vol.216 , Issue.5 , pp. 341-346
    • Simões, J.A.1    Vaz, M.A.2
  • 3
    • 0034975523 scopus 로고    scopus 로고
    • Simulation of hip operations and design of custom-made endoprostheses using virtual reality techniques
    • H. Handels, J. Ehrhardt, W. Plötz, and S. J. Pöppl (2001) Simulation of hip operations and design of custom-made endoprostheses using virtual reality techniques. Methods of Information in Medicine, 40(2):74-77.
    • (2001) Methods of Information in Medicine , vol.40 , Issue.2 , pp. 74-77
    • Handels, H.1    Ehrhardt, J.2    Plötz, W.3    Pöppl, S.J.4
  • 4
    • 0031003123 scopus 로고    scopus 로고
    • Computer-guided robotassisted surgery in hip endoprostheses
    • M. Börner, A. Bauer, and A. Lahmer (1997) Computer-guided robotassisted surgery in hip endoprostheses. Orthopäde, 26(3):251-257.
    • (1997) Orthopäde , vol.26 , Issue.3 , pp. 251-257
    • Börner, M.1    Bauer, A.2    Lahmer, A.3
  • 7
    • 0028533296 scopus 로고
    • Correlations between orthogonal mechanical properties and density of trabecular bone: Use of different densitometric measures
    • J. H. Keyak, I. Y. Lee, and H. B. Skinner (1994) Correlations between orthogonal mechanical properties and density of trabecular bone: Use of different densitometric measures. Journal of Biomedical Materials Research, 28(11):1329-1336.
    • (1994) Journal of Biomedical Materials Research , vol.28 , Issue.11 , pp. 1329-1336
    • Keyak, J.H.1    Lee, I.Y.2    Skinner, H.B.3
  • 8
    • 2642556592 scopus 로고    scopus 로고
    • Comparison of in situ and in vitro CT scan-based finite element model predictions of proximal femoral fracture load
    • J. H. Keyak and Y. Falkinstein (2003) Comparison of in situ and in vitro CT scan-based finite element model predictions of proximal femoral fracture load. Medical Engineering and Physics, 25(9):781-787.
    • (2003) Medical Engineering and Physics , vol.25 , Issue.9 , pp. 781-787
    • Keyak, J.H.1    Falkinstein, Y.2
  • 9
    • 0028504004 scopus 로고
    • Trabecular bone exhibits fully linear elastic behavior and yields at low strains
    • T. M. Keaveny, E. Guo, E. F. Wachtel, T. A. McMahon, and W. C. Hayes (1994) Trabecular bone exhibits fully linear elastic behavior and yields at low strains. Journal of Biomechanics, 27(9):1127-1136.
    • (1994) Journal of Biomechanics , vol.27 , Issue.9 , pp. 1127-1136
    • Keaveny, T.M.1    Guo, E.2    Wachtel, E.F.3    McMahon, T.A.4    Hayes, W.C.5
  • 10
    • 33747163357 scopus 로고    scopus 로고
    • A multigrid framework for realtime simulation of deformable bodies
    • J. Georgii and R. Westermann (2006) A multigrid framework for realtime simulation of deformable bodies. Computer & Graphics, 30(3):408-415.
    • (2006) Computer & Graphics , vol.30 , Issue.3 , pp. 408-415
    • Georgii, J.1    Westermann, R.2
  • 11
    • 63549102110 scopus 로고    scopus 로고
    • Single-pass GPU solid voxelization for real-time applications
    • E. Eisemann and X. Décoret (2008) Single-pass GPU solid voxelization for real-time applications. Proceedings of Graphics Interface 2008, pp 73-80.
    • (2008) Proceedings of Graphics Interface , pp. 73-80
    • Eisemann, E.1    Décoret, X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.