메뉴 건너뛰기




Volumn 25, Issue 4, 2009, Pages 1604-1607

Aortic blood flow characteristics of different extracorporeal circulation techniques during cardiac surgery - A computational fluid dynamics study

Author keywords

Antegrade perfusion; Aortic blood flow; Computational fluid dynamics; Extracorporeal circulation; Retrograde perfusion

Indexed keywords

BIOINFORMATICS; BIOMECHANICS; BIOMEDICAL ENGINEERING; BIOPHYSICS; BLOOD VESSELS; CARDIOVASCULAR SURGERY; COMPUTATIONAL FLUID DYNAMICS; HEMODYNAMICS; MEDICAL IMAGE PROCESSING; MEDICAL PHYSICS; SHEAR FLOW; SHEAR STRESS;

EID: 77950149534     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03882-2_425     Document Type: Conference Paper
Times cited : (2)

References (9)
  • 1
    • 0035034343 scopus 로고    scopus 로고
    • Combined MR imaging and CFD simulation of flow in the human descending aorta
    • Wood NB, Weston SJ, Kilner PJ et al. (2001) Combined MR imaging and CFD simulation of flow in the human descending aorta. J Magn Reson Imaging. 13(5):699-713
    • (2001) J Magn Reson Imaging , vol.13 , Issue.5 , pp. 699-713
    • Wood, N.B.1    Weston, S.J.2    Kilner, P.J.3
  • 2
    • 0036069315 scopus 로고    scopus 로고
    • Numerical simulation of steady flow fields in a model of abdominal aorta with its peripheral branches
    • Lee D & Chen JY (2002) Numerical simulation of steady flow fields in a model of abdominal aorta with its peripheral branches. J Biomech. 35(8):1115-1122
    • (2002) J Biomech , vol.35 , Issue.8 , pp. 1115-1122
    • Lee, D.1    Chen, J.Y.2
  • 3
    • 38349048315 scopus 로고    scopus 로고
    • Three-dimensional numerical simulation of blood flow in the aortic arch during cardiopulmonary bypass
    • Tokuda Y, Song MH, Ueda Y et al. (2008) Three-dimensional numerical simulation of blood flow in the aortic arch during cardiopulmonary bypass. Eur J Cardiothorac Surg. 33(2):164-167
    • (2008) Eur J Cardiothorac Surg , vol.33 , Issue.2 , pp. 164-167
    • Tokuda, Y.1    Song, M.H.2    Ueda, Y.3
  • 4
    • 43549097815 scopus 로고    scopus 로고
    • Hydrodynamic evaluation of axillary artery perfusion for normal and diseased aorta
    • Minakawa M, Fukuda I, Inamura T et al. (2008) Hydrodynamic evaluation of axillary artery perfusion for normal and diseased aorta. Gen Thorac Cardiovasc Surg. 56(5):215-221
    • (2008) Gen Thorac Cardiovasc Surg , vol.56 , Issue.5 , pp. 215-221
    • Minakawa, M.1    Fukuda, I.2    Inamura, T.3
  • 9
    • 3543073595 scopus 로고    scopus 로고
    • Version 6.3. Fluent Inc. Lebanon, USA
    • Fluent (2006), Users Guide, Version 6.3. Fluent Inc. Lebanon, USA
    • Users Guide


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.