메뉴 건너뛰기




Volumn 25, Issue 4, 2009, Pages 2062-2065

Slow stimulus artifact removal through peak-valley detection of neuronal signals recorded from somatosensory cortex by high resolution brain-chip interface

Author keywords

Artifact removal; Brain chip interface; Peak valley detection; Somatosensory cortex; Stimulus artifact

Indexed keywords

BATCH DATA PROCESSING; BIOINFORMATICS; BIOMECHANICS; BIOMEDICAL ENGINEERING; BIOPHYSICS; BRAIN; ELECTROPHYSIOLOGY; LANDFORMS; MEDICAL PHYSICS; NEURONS;

EID: 77950144604     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03882-2_547     Document Type: Conference Paper
Times cited : (15)

References (11)
  • 1
    • 0029430874 scopus 로고
    • Stimulus Artifact Reduction in Somatosensory Evoked Potential Acquisition: A Conceptual Model
    • 20-23 September, Montreal, Canada, pp
    • Linda McLean, Robert N. Scott, Philip A. Parker (1995) Stimulus Artifact Reduction in Somatosensory Evoked Potential Acquisition: A Conceptual Model, IEEE-EMBC and CMBEC, 1995, 20-23 September, Montreal, Canada, pp. 909-910.
    • (1995) IEEE-EMBC and CMBEC , pp. 909-910
    • McLean, L.1    Scott, R.N.2    Parker, P.A.3
  • 2
    • 77950155111 scopus 로고
    • editor. The biomedical engineering handbook. Boca Raton: Hartford: CRC Press:IEEE Press;
    • Nagel J. (1995) Biopotential amplifiers. In: Bronzino J, editor. The biomedical engineering handbook. Boca Raton: Hartford: CRC Press:IEEE Press; 1995. p.1189.
    • (1995) Biopotential amplifiers , pp. 1189
    • Nagel, J.1
  • 3
    • 0037196235 scopus 로고    scopus 로고
    • A template subtraction method for stimulus artifact removal in high-frequency deep brain stimulation
    • Hashimoto T., Elder C., Vitek J. (2002) A template subtraction method for stimulus artifact removal in high-frequency deep brain stimulation, J Neurosci Meth, 113(2), pp. 181-186.
    • (2002) J Neurosci Meth , vol.113 , Issue.2 , pp. 181-186
    • Hashimoto, T.1    Elder, C.2    Vitek, J.3
  • 4
    • 0034945059 scopus 로고    scopus 로고
    • Auditory nerve fiber responses to electric stimulation: Modulated and unmodulated pulse trains
    • Litvak L, Delgutte B, Eddington D. (2001) Auditory nerve fiber responses to electric stimulation: modulated and unmodulated pulse trains. J Acoust Soc Am, 110(1), pp. 368-79.
    • (2001) J Acoust Soc Am , vol.110 , Issue.1 , pp. 368-379
    • Litvak, L.1    Delgutte, B.2    Eddington, D.3
  • 5
    • 0032910671 scopus 로고    scopus 로고
    • Electrically evoked single-fiber action potentials from cat: Responses to monopolar, monophasic stimulation
    • Miller C., Abbas P., Robinson B., Rubinstein J., Matsuoka A. (1999) Electrically evoked single-fiber action potentials from cat: responses to monopolar, monophasic stimulation. Hearing Res, 130(1-2), pp. 197-218.
    • (1999) Hearing Res , vol.130 , Issue.1-2 , pp. 197-218
    • Miller, C.1    Abbas, P.2    Robinson, B.3    Rubinstein, J.4    Matsuoka, A.5
  • 6
    • 0034658085 scopus 로고    scopus 로고
    • A digital averaging method for removal of stimulus artifacts in neurophysiologic experiments
    • Wichmann T. (2000) A digital averaging method for removal of stimulus artifacts in neurophysiologic experiments, J Neurosci Meth, 98(1), pp. 57-62.
    • (2000) J Neurosci Meth , vol.98 , Issue.1 , pp. 57-62
    • Wichmann, T.1
  • 7
    • 17444396361 scopus 로고    scopus 로고
    • Methods for isolating extracellular action potentials and removing stimulus artifacts from microelectrode recordings of neurons requiring minimal operator intervention
    • Montgomery E., Gale J., Huang H.(2005) Methods for isolating extracellular action potentials and removing stimulus artifacts from microelectrode recordings of neurons requiring minimal operator intervention, J Neurosci Meth, 144(1), pp. 107-125.
    • (2005) J Neurosci Meth , vol.144 , Issue.1 , pp. 107-125
    • Montgomery, E.1    Gale, J.2    Huang, H.3
  • 8
    • 0037201958 scopus 로고    scopus 로고
    • Real-time multi-channel stimulus artifact suppression by local curve fitting
    • Wagenaar D., Potter S. (2002) Real-time multi-channel stimulus artifact suppression by local curve fitting, J Neurosci Meth, 120(2), pp. 113-120.
    • (2002) J Neurosci Meth , vol.120 , Issue.2 , pp. 113-120
    • Wagenaar, D.1    Potter, S.2
  • 9
    • 41949124480 scopus 로고    scopus 로고
    • A novel stimulus artifact removal technique for high-rate electrical stimulation
    • Leon F. Heffer, James B. Fallon (2008) A novel stimulus artifact removal technique for high-rate electrical stimulation, J Neurosci Meth, 170, (2008), pp. 277-284.
    • (2008) J Neurosci Meth , vol.170 , pp. 277-284
    • Heffer, L.F.1    Fallon, J.B.2
  • 10
    • 33646142765 scopus 로고    scopus 로고
    • Functional Na+ channels in cell adhesion probed by transistor recording
    • Schmidtner M., Fromherz P. (2006) Functional Na+ channels in cell adhesion probed by transistor recording. Biophys J. 90: 183-189.
    • (2006) Biophys J , vol.90 , pp. 183-189
    • Schmidtner, M.1    Fromherz, P.2
  • 11
    • 5844282347 scopus 로고    scopus 로고
    • Neuron Adhesion on a Silicon Chip Probed by an Array of Field-Effect Transistors
    • Weis R., Müller B., Fromherz P. (1996) Neuron Adhesion on a Silicon Chip Probed by an Array of Field-Effect Transistors. Phys Rev Lett, Vol. 76, No. 2, pp. 327-330.
    • (1996) Phys Rev Lett , vol.76 , Issue.2 , pp. 327-330
    • Weis, R.1    Müller, B.2    Fromherz, P.3