Real climate experimental study of two double window systems with preheating of ventilation air

Author keywords

Double window; Experimental measurements; Solar heating; Ventilation air

Indexed keywords

AIR FLOW-RATE; AIR TEMPERATURE; AIR-GAPS; BUILDING TECHNOLOGIES; DOUBLE WINDOW; EXISTING BUILDING; EXPERIMENTAL MEASUREMENTS; EXPERIMENTAL STUDIES; HEATING SEASON; INDOOR/OUTDOOR; MOUNTAIN REGIONS; OPERATIONAL ENERGY; OUTDOOR WEATHER CONDITIONS; PORTUGAL; TEMPERATURE DIFFERENCES; TEST CELL; THERMAL PERFORMANCE; WINDOW SYSTEM;

EID: 77950061074     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2010.01.003     Document Type: Article
Times cited : (57)

References (13)
  • 1
    • 0041511798 scopus 로고    scopus 로고
    • Evaluation of earth-to-air heat exchangers with a standardised method to calculate energy efficiency
    • Pfafferott J. Evaluation of earth-to-air heat exchangers with a standardised method to calculate energy efficiency. Energy and Buildings 35 (2003) 971-983
    • (2003) Energy and Buildings , vol.35 , pp. 971-983
    • Pfafferott, J.1
  • 3
    • 77950035788 scopus 로고    scopus 로고
    • Thermal simulation and economic assessment of unglazed transpired solar collector systems
    • American Solar Energy Society
    • Summers D.N., Mitchell J.W., Klein S.A., and Beckman W.A. Thermal simulation and economic assessment of unglazed transpired solar collector systems. Proceedings of Solar 96. American Solar Energy Society (1996)
    • (1996) Proceedings of Solar 96
    • Summers, D.N.1    Mitchell, J.W.2    Klein, S.A.3    Beckman, W.A.4
  • 4
    • 0033157411 scopus 로고    scopus 로고
    • Optimized finned absorber geometries for solar air heating collectors
    • Pottler K., Sippel C.M., Beck A., and Fricke J. Optimized finned absorber geometries for solar air heating collectors. Solar Energy 67 (1999) 35-52
    • (1999) Solar Energy , vol.67 , pp. 35-52
    • Pottler, K.1    Sippel, C.M.2    Beck, A.3    Fricke, J.4
  • 6
    • 0043014624 scopus 로고    scopus 로고
    • Test cell evaluation of supply air windows to characterise their optimum performance and its verification by the use of modelling techniques
    • McEvoy M.E., Southall R.G., and Baker P.H. Test cell evaluation of supply air windows to characterise their optimum performance and its verification by the use of modelling techniques. Energy and Buildings 35 (2003) 1009-1020
    • (2003) Energy and Buildings , vol.35 , pp. 1009-1020
    • McEvoy, M.E.1    Southall, R.G.2    Baker, P.H.3
  • 7
    • 0142153034 scopus 로고    scopus 로고
    • Numerical analysis of the thermal behaviour of glazed ventilated facades in Mediterranean climates. Part II. Applications and analysis of results
    • Faggembauu D., Costa M., Soria M., and Oliva A. Numerical analysis of the thermal behaviour of glazed ventilated facades in Mediterranean climates. Part II. Applications and analysis of results. Solar Energy 75 (2003) 229-239
    • (2003) Solar Energy , vol.75 , pp. 229-239
    • Faggembauu, D.1    Costa, M.2    Soria, M.3    Oliva, A.4
  • 8
    • 77950043268 scopus 로고    scopus 로고
    • Double skin, airflow facades: will the popular European model work in the USA?
    • Massachusetts Institute of Technology
    • Arons D.M.M., and Glicksman L.R. Double skin, airflow facades: will the popular European model work in the USA?. Building Technology Program (2003), Massachusetts Institute of Technology
    • (2003) Building Technology Program
    • Arons, D.M.M.1    Glicksman, L.R.2
  • 9
    • 77950062035 scopus 로고    scopus 로고
    • UNFCCC, Kyoto Protocol to the United Nations framework convention on climate change, United Nations convention on climate change, FCC/CP/L.7/Add1, Kyoto, 1990.
    • UNFCCC, Kyoto Protocol to the United Nations framework convention on climate change, United Nations convention on climate change, FCC/CP/L.7/Add1, Kyoto, 1990.
  • 11
    • 77950065304 scopus 로고    scopus 로고
    • MSc thesis, Department of Mechanical Engineering, University of Strathclyde, Glasgow, UK
    • A. Dickson, Modelling double-skin facades, MSc thesis, Department of Mechanical Engineering, University of Strathclyde, Glasgow, UK, 2004.
    • (2004) Modelling double-skin facades
    • Dickson, A.1
  • 13
    • 0033713927 scopus 로고    scopus 로고
    • Test cell analysis of the use of a supply air window as a passive solar component
    • Baker P.H., and McEvoy M. Test cell analysis of the use of a supply air window as a passive solar component. Solar Energy 69 (2000) 113-130
    • (2000) Solar Energy , vol.69 , pp. 113-130
    • Baker, P.H.1    McEvoy, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.