메뉴 건너뛰기




Volumn 74, Issue 1, 2010, Pages 236-240

Automatic assessment of the knee alignment angle on full-limb radiographs

Author keywords

Automatic; Computer aided diagnosis; Full limb radiographs; Knee; Knee alignment; Pattern recognition

Indexed keywords

ALIGNMENT ANGLE; ALIGNMENT PATTERNS; AUTOMATIC ASSESSMENT; AUTOMATIC METHOD; CROSS VALIDATION; HIGHLY-CORRELATED; LEAVE-ONE-OUT; MEAN ABSOLUTE DIFFERENCES; MEAN AGES; REPEATED MEASUREMENTS; STATISTICAL EVALUATION; USER INTERACTION;

EID: 77950030878     PISSN: 0720048X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejrad.2009.02.004     Document Type: Article
Times cited : (9)

References (23)
  • 1
    • 12144260812 scopus 로고    scopus 로고
    • Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs
    • Sailer J., Scharitzer M., Peloschek P., et al. Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs. Eur Radiol 15 (2005) 170-173
    • (2005) Eur Radiol , vol.15 , pp. 170-173
    • Sailer, J.1    Scharitzer, M.2    Peloschek, P.3
  • 2
    • 0023189701 scopus 로고
    • Radiographic analysis of the axial alignment of the lower extremity
    • Moreland J.R., Bassett L.W., and Hanker G.J. Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg 69A (1987) 745-749
    • (1987) J Bone Joint Surg , vol.69 A , pp. 745-749
    • Moreland, J.R.1    Bassett, L.W.2    Hanker, G.J.3
  • 3
    • 0017353885 scopus 로고
    • Influence of positioning of prothesis in total knee replacement
    • Lotke P.A., and Ecker M.L. Influence of positioning of prothesis in total knee replacement. J Bone Joint Surg 59A (1977) 77-79
    • (1977) J Bone Joint Surg , vol.59 A , pp. 77-79
    • Lotke, P.A.1    Ecker, M.L.2
  • 4
    • 0026758487 scopus 로고
    • Mechanical axis deviation of the lower limbs: preoperative planning of uniapicular deformities of the tibia or femur
    • Paley D., and Tetsworth K. Mechanical axis deviation of the lower limbs: preoperative planning of uniapicular deformities of the tibia or femur. Clin Orthop 280 (1992) 48-64
    • (1992) Clin Orthop , vol.280 , pp. 48-64
    • Paley, D.1    Tetsworth, K.2
  • 5
    • 0023893141 scopus 로고
    • Radiographic assessment of knee alignment after total knee arthroplasty
    • Petersen T.L., and Engh G.A. Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3 (1988) 67-72
    • (1988) J Arthroplasty , vol.3 , pp. 67-72
    • Petersen, T.L.1    Engh, G.A.2
  • 6
    • 0027453062 scopus 로고
    • Proximal tibial osteotomy: a critical long-term study of eighty-seven cases
    • Coventry M.B., Ilstrup D.M., and Wallrichs S.L. Proximal tibial osteotomy: a critical long-term study of eighty-seven cases. J Bone Joint Surg Am 75 (1993) 196-201
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 196-201
    • Coventry, M.B.1    Ilstrup, D.M.2    Wallrichs, S.L.3
  • 7
    • 2942739119 scopus 로고    scopus 로고
    • Alignment influences wear in the knee after medial unicompartmental arthroplasty
    • Hernigou P., and Deschamps G. Alignment influences wear in the knee after medial unicompartmental arthroplasty. Clin Orthop Relat Res 423 (2004) 161-165
    • (2004) Clin Orthop Relat Res , vol.423 , pp. 161-165
    • Hernigou, P.1    Deschamps, G.2
  • 8
    • 1542329557 scopus 로고    scopus 로고
    • Longitudinal study of the relationship between the knee angle and tibiofemoral cartilage volume in subjects with knee osteoarthritis
    • Cicuttini F., Wluka A., Hankin J., et al. Longitudinal study of the relationship between the knee angle and tibiofemoral cartilage volume in subjects with knee osteoarthritis. Rheumatology 43 (2004) 321-324
    • (2004) Rheumatology , vol.43 , pp. 321-324
    • Cicuttini, F.1    Wluka, A.2    Hankin, J.3
  • 9
    • 0034933989 scopus 로고    scopus 로고
    • The role of knee alignment in disease progression and functional decline in knee osteoarthritis
    • Sharma L., Song J., Felson D.T., et al. The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286 (2001) 188-195
    • (2001) JAMA , vol.286 , pp. 188-195
    • Sharma, L.1    Song, J.2    Felson, D.T.3
  • 10
    • 34247853376 scopus 로고    scopus 로고
    • Improved precision in quantifying knee alignment angle
    • Goker B., and Block J.A. Improved precision in quantifying knee alignment angle. Clin Orthop Relat Res 458 (2007) 145-149
    • (2007) Clin Orthop Relat Res , vol.458 , pp. 145-149
    • Goker, B.1    Block, J.A.2
  • 11
    • 0025358109 scopus 로고
    • A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee
    • Krackow K.A., Pepe C.L., and Galloway E.J. A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee. Orthopedics 13 (1990) 861-868
    • (1990) Orthopedics , vol.13 , pp. 861-868
    • Krackow, K.A.1    Pepe, C.L.2    Galloway, E.J.3
  • 12
    • 0025735810 scopus 로고
    • A quantitative approach to radiography of the lower limb
    • Cooke T.D.V., Scudamore R.A., Bryant J.T., et al. A quantitative approach to radiography of the lower limb. J Bone Joint Surg 73B (1991) 715-720
    • (1991) J Bone Joint Surg , vol.73 B , pp. 715-720
    • Cooke, T.D.V.1    Scudamore, R.A.2    Bryant, J.T.3
  • 13
    • 0025967928 scopus 로고
    • A standardized technique for lower limb radiography. Practice, applications, and error analysis
    • Siu D., Cooke T.D., Broekhoven L.D., et al. A standardized technique for lower limb radiography. Practice, applications, and error analysis. Invest Radiol 26 (1991) 71-77
    • (1991) Invest Radiol , vol.26 , pp. 71-77
    • Siu, D.1    Cooke, T.D.2    Broekhoven, L.D.3
  • 14
    • 0030237770 scopus 로고    scopus 로고
    • Angular configuration of the knee: comparison of conventional measurements and the QUESTOR Precision Radiography system
    • Sanfridsson J., Ryd L., Eklund K., et al. Angular configuration of the knee: comparison of conventional measurements and the QUESTOR Precision Radiography system. Acta Radiol 37 (1996) 633-638
    • (1996) Acta Radiol , vol.37 , pp. 633-638
    • Sanfridsson, J.1    Ryd, L.2    Eklund, K.3
  • 15
    • 0005175717 scopus 로고    scopus 로고
    • Radiographic evaluation and preoperative planning for high tibial osteotomies
    • Brown G.A., and Amendola A. Radiographic evaluation and preoperative planning for high tibial osteotomies. Oper Tech Sports Med 8 (2000) 2-14
    • (2000) Oper Tech Sports Med , vol.8 , pp. 2-14
    • Brown, G.A.1    Amendola, A.2
  • 17
    • 0028463039 scopus 로고
    • The use of active shape models for locating structures in medical images
    • Cootes T.F., Hill A., Taylor C.J., et al. The use of active shape models for locating structures in medical images. Image Vision Comput 12 6 (1994) 355-366
    • (1994) Image Vision Comput , vol.12 , Issue.6 , pp. 355-366
    • Cootes, T.F.1    Hill, A.2    Taylor, C.J.3
  • 18
    • 77950048568 scopus 로고    scopus 로고
    • Estimation of fit confidence in Active Shape Model search for the reliable measurement of knee alignment
    • Widhalm P., Langs G., Donner R., et al. Estimation of fit confidence in Active Shape Model search for the reliable measurement of knee alignment. Proceedings of AAPR'08 (2008) 78-90
    • (2008) Proceedings of AAPR'08 , pp. 78-90
    • Widhalm, P.1    Langs, G.2    Donner, R.3
  • 19
    • 0033624950 scopus 로고    scopus 로고
    • An ultra-fast user-steered image segmentation paradigm: live wire on the fly
    • Falcão A.X., Udupa J.K., and Miyazawa F.K. An ultra-fast user-steered image segmentation paradigm: live wire on the fly. IEEE Trans Med Imaging 19 1 (2000) 55-62
    • (2000) IEEE Trans Med Imaging , vol.19 , Issue.1 , pp. 55-62
    • Falcão, A.X.1    Udupa, J.K.2    Miyazawa, F.K.3
  • 21
    • 84908219488 scopus 로고
    • Statistical method for assessing agreement between two methods of clinical measurement
    • Bland J., and Altman D. Statistical method for assessing agreement between two methods of clinical measurement. Lancet 1 8476 (1986) 307-310
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.1    Altman, D.2
  • 22
    • 36248990317 scopus 로고    scopus 로고
    • An automatic model-based system for joint space measurements on hand radiographs: initial experience
    • Peloschek P., Langs G., Weber M., et al. An automatic model-based system for joint space measurements on hand radiographs: initial experience. Radiology 245 (2007) 855-862
    • (2007) Radiology , vol.245 , pp. 855-862
    • Peloschek, P.1    Langs, G.2    Weber, M.3
  • 23
    • 77950024907 scopus 로고    scopus 로고
    • Cootes TF, Taylor CJ. Active Shape Models - Smart Snakes. In: Hogg D et al. (Eds.): BMVC92. Proceedings of the British Machine Vision Conference 1992; 266-75.
    • Cootes TF, Taylor CJ. Active Shape Models - "Smart Snakes". In: Hogg D et al. (Eds.): BMVC92. Proceedings of the British Machine Vision Conference 1992; 266-75.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.