메뉴 건너뛰기




Volumn 146, Issue 1, 2010, Pages 283-288

Comparison of trihexadecylalkylammonium iodides as ion-exchangers for polyacrylate and poly(vinyl chloride) based iodide-selective electrodes

Author keywords

All solid state potentiometric sensor; Iodide ion selective electrode; Poly(vinyl chloride) membrane; Polyacrylate membrane; Quaternary ammonium iodide

Indexed keywords

ALKYL CHAIN; ANALYTICAL PARAMETERS; CARBON ATOMS; CONCENTRATION RANGES; DETECTION LIMITS; IODIDE ION; ISODECYL ACRYLATE; MEMBRANE COMPOSITION; MEMBRANE SENSORS; N-BUTYL ACRYLATE; POLY (VINYL CHLORIDE) MEMBRANE; POLY(N-BUTYL ACRYLATE); POLYACRYLATE-BASED MEMBRANE; QUATERNARY AMMONIUM IODIDE; SELECTIVE ELECTRODES; STERIC HINDRANCES;

EID: 77949916380     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2010.02.016     Document Type: Article
Times cited : (15)

References (18)
  • 2
    • 30944444781 scopus 로고    scopus 로고
    • Conducting polymer-based solid-state ion-selective electrodes
    • Bobacka J. Conducting polymer-based solid-state ion-selective electrodes. Electroanalysis 18 (2006) 7-18
    • (2006) Electroanalysis , vol.18 , pp. 7-18
    • Bobacka, J.1
  • 3
    • 29544444766 scopus 로고    scopus 로고
    • Optimizing the analytical performance and construction of ion-selective electrodes with conducting polymer-based ion-to-electron transducers
    • Michalska A. Optimizing the analytical performance and construction of ion-selective electrodes with conducting polymer-based ion-to-electron transducers. Anal. Bioanal. Chem. 384 (2006) 391-406
    • (2006) Anal. Bioanal. Chem. , vol.384 , pp. 391-406
    • Michalska, A.1
  • 4
    • 0029885415 scopus 로고    scopus 로고
    • Methacrylate-acrylate based polymers of low plasticizer content for potassium ion-selective membranes
    • Heng L.Y., and Hall E.A.H. Methacrylate-acrylate based polymers of low plasticizer content for potassium ion-selective membranes. Anal. Chim. Acta 324 (1996) 47-56
    • (1996) Anal. Chim. Acta , vol.324 , pp. 47-56
    • Heng, L.Y.1    Hall, E.A.H.2
  • 5
    • 0002797481 scopus 로고    scopus 로고
    • "Self-plasticizing" ion-selective membranes
    • Heng L.Y., Hall E.A.H., and Producing. "Self-plasticizing" ion-selective membranes. Anal. Chem. 72 (2000) 42-51
    • (2000) Anal. Chem. , vol.72 , pp. 42-51
    • Heng, L.Y.1    Hall, E.A.H.2    Producing3
  • 7
    • 1842734661 scopus 로고    scopus 로고
    • Ion-transport and diffusion coefficients of non-plasticized methacrylic-acrylic ion-selective membranes
    • Heng L.Y., Toth K., and Hall E.A.H. Ion-transport and diffusion coefficients of non-plasticized methacrylic-acrylic ion-selective membranes. Talanta 63 (2004) 73-87
    • (2004) Talanta , vol.63 , pp. 73-87
    • Heng, L.Y.1    Toth, K.2    Hall, E.A.H.3
  • 9
    • 0034699596 scopus 로고    scopus 로고
    • Novel approach of immobilization of calix[4]arene type ionophore in 'self-plasticized' polymeric membrane
    • Malinowska E., Gawart L., Parzuchowski P., Rokicki G., and Brzózka Z. Novel approach of immobilization of calix[4]arene type ionophore in 'self-plasticized' polymeric membrane. Anal. Chim. Acta 421 (2000) 93-101
    • (2000) Anal. Chim. Acta , vol.421 , pp. 93-101
    • Malinowska, E.1    Gawart, L.2    Parzuchowski, P.3    Rokicki, G.4    Brzózka, Z.5
  • 10
    • 41149099695 scopus 로고    scopus 로고
    • Composite polyacrylate-poly(3,4-ethylenedioxythiophene) membranes for improved all-solid-state ion-selective sensors
    • Rzewuska A., Wojciechowski M., Bulska E., Hall E.A.H., Maksymiuk K., and Michalska A. Composite polyacrylate-poly(3,4-ethylenedioxythiophene) membranes for improved all-solid-state ion-selective sensors. Anal. Chem. 80 (2008) 321-327
    • (2008) Anal. Chem. , vol.80 , pp. 321-327
    • Rzewuska, A.1    Wojciechowski, M.2    Bulska, E.3    Hall, E.A.H.4    Maksymiuk, K.5    Michalska, A.6
  • 14
    • 0043064001 scopus 로고    scopus 로고
    • Improving the detection limit of anion-selective electrodes: an iodide-selective membrane with a nanomolar detection limit
    • Malon A., Radu A., Qin W., Qin Y., Ceresa A., Maj-Zurawska M., Bakker E., and Pretsch E. Improving the detection limit of anion-selective electrodes: an iodide-selective membrane with a nanomolar detection limit. Anal. Chem. 75 (2003) 3865-3871
    • (2003) Anal. Chem. , vol.75 , pp. 3865-3871
    • Malon, A.1    Radu, A.2    Qin, W.3    Qin, Y.4    Ceresa, A.5    Maj-Zurawska, M.6    Bakker, E.7    Pretsch, E.8
  • 15
    • 0001563583 scopus 로고    scopus 로고
    • Anion-selective electrodes based on long-chain methyltrialkylammonium salts
    • Ozawa S., Miyagi H., Shibata Y., Oki N., Kunitake T., and Keller W.E. Anion-selective electrodes based on long-chain methyltrialkylammonium salts. Anal. Chem. 68 (1996) 4149-4152
    • (1996) Anal. Chem. , vol.68 , pp. 4149-4152
    • Ozawa, S.1    Miyagi, H.2    Shibata, Y.3    Oki, N.4    Kunitake, T.5    Keller, W.E.6
  • 16
    • 1842633875 scopus 로고    scopus 로고
    • Effects of ion association of lipophilic quaternary ammonium salts in ion-exchange and potentiometric selectivity
    • Egorov V.V., Rakhman'ko E.M., Okaev E.B., Pomelenok E.V., and Nazarov V.A. Effects of ion association of lipophilic quaternary ammonium salts in ion-exchange and potentiometric selectivity. Talanta 63 (2004) 119-130
    • (2004) Talanta , vol.63 , pp. 119-130
    • Egorov, V.V.1    Rakhman'ko, E.M.2    Okaev, E.B.3    Pomelenok, E.V.4    Nazarov, V.A.5
  • 17
    • 4544314072 scopus 로고    scopus 로고
    • All-solid-state chloride sensors with poly(3-octylthiophene) matrix and trihexadecylmethylammonium chlorides as ion exchanger salt
    • Sjöberg-Eerola P., Bobacka J., Sokalski T., Mieczkowski J., Ivaska A., and Lewenstam A. All-solid-state chloride sensors with poly(3-octylthiophene) matrix and trihexadecylmethylammonium chlorides as ion exchanger salt. Electroanalysis 16 (2004) 379-385
    • (2004) Electroanalysis , vol.16 , pp. 379-385
    • Sjöberg-Eerola, P.1    Bobacka, J.2    Sokalski, T.3    Mieczkowski, J.4    Ivaska, A.5    Lewenstam, A.6
  • 18
    • 70349510275 scopus 로고    scopus 로고
    • Quantifying primary silver ions contents in poly(vinyl chloride) and poly(n-butyl acrylate) ion-selective membranes
    • Michalska A., Wojciechowski M., Bulska E., and Maksymiuk K. Quantifying primary silver ions contents in poly(vinyl chloride) and poly(n-butyl acrylate) ion-selective membranes. Electroanalysis 17-18 (2009) 1931-1938
    • (2009) Electroanalysis , vol.17-18 , pp. 1931-1938
    • Michalska, A.1    Wojciechowski, M.2    Bulska, E.3    Maksymiuk, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.