메뉴 건너뛰기




Volumn 35, Issue 4, 2010, Pages 639-644

Biomechanical Comparison of Contemporary Clavicle Fixation Devices

Author keywords

Biomechanics; clavicle; fixation; intramedullary pin; precontoured clavicle plates; transverse fracture

Indexed keywords

ARTICLE; BIOMECHANICS; BONE PLATE; BONE SCREW; CLAVICLE; CLAVICLE FRACTURE; COMPARATIVE STUDY; CONTROLLED STUDY; FIXATION DEVICE; FRACTURE FIXATION; INTRAMEDULLARY NAILING; MECHANICAL STRESS; PRIORITY JOURNAL; RIGIDITY; STRENGTH; TORQUE;

EID: 77949914138     PISSN: 03635023     EISSN: 15316564     Source Type: Journal    
DOI: 10.1016/j.jhsa.2009.12.012     Document Type: Article
Times cited : (48)

References (24)
  • 1
    • 33846052672 scopus 로고    scopus 로고
    • Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multi-center, randomized clinical trial
    • Canadian Orthopaedic Trauma Society
    • Canadian Orthopaedic Trauma Society. Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multi-center, randomized clinical trial. J Bone Joint Surg 89A (2007) 1-10
    • (2007) J Bone Joint Surg , vol.89 A , pp. 1-10
  • 2
    • 24644480089 scopus 로고    scopus 로고
    • Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the Evidence-Based Orthopaedic Trauma Working Group
    • Zlowodzki M., Zelle B.A., Cole P.A., Jeray K., and McKee M.D. Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the Evidence-Based Orthopaedic Trauma Working Group. J Orthop Trauma 19 (2005) 504-507
    • (2005) J Orthop Trauma , vol.19 , pp. 504-507
    • Zlowodzki, M.1    Zelle, B.A.2    Cole, P.A.3    Jeray, K.4    McKee, M.D.5
  • 3
    • 0000961509 scopus 로고
    • The function of the clavicle: its surgical significance
    • Abbott L.C., and Lucas D.B. The function of the clavicle: its surgical significance. Ann Surg 140 (1954) 583-599
    • (1954) Ann Surg , vol.140 , pp. 583-599
    • Abbott, L.C.1    Lucas, D.B.2
  • 4
    • 23044433382 scopus 로고    scopus 로고
    • Brachial plexus palsy after intramedullary fixation of a clavicular fracture. A report of three cases
    • Ring D., and Holovacs T. Brachial plexus palsy after intramedullary fixation of a clavicular fracture. A report of three cases. J Bone Joint Surg 87A (2005) 1834-1837
    • (2005) J Bone Joint Surg , vol.87 A , pp. 1834-1837
    • Ring, D.1    Holovacs, T.2
  • 5
    • 0030785720 scopus 로고    scopus 로고
    • Closed treatment of displaced middle-third fractures of the clavicle gives poor results
    • Hill J.M., McGuire M.H., and Crosby L.A. Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg 79B (1997) 537-539
    • (1997) J Bone Joint Surg , vol.79 B , pp. 537-539
    • Hill, J.M.1    McGuire, M.H.2    Crosby, L.A.3
  • 6
    • 0032196560 scopus 로고    scopus 로고
    • Mid-clavicle fractures in adults: end result study after conservative treatment
    • Nordqvist A., Petersson C.J., and Redlund-Johnell I. Mid-clavicle fractures in adults: end result study after conservative treatment. J Orthop Trauma 12 (1998) 572-576
    • (1998) J Orthop Trauma , vol.12 , pp. 572-576
    • Nordqvist, A.1    Petersson, C.J.2    Redlund-Johnell, I.3
  • 7
    • 4544230492 scopus 로고    scopus 로고
    • Can we predict long-term sequelae after fractures of the clavicle based on initial findings?. A prospective study with nine to ten years of follow-up
    • Nowak J., Holgersson M., and Larsson S. Can we predict long-term sequelae after fractures of the clavicle based on initial findings?. A prospective study with nine to ten years of follow-up. J Shoulder Elbow Surg 13 (2004) 479-486
    • (2004) J Shoulder Elbow Surg , vol.13 , pp. 479-486
    • Nowak, J.1    Holgersson, M.2    Larsson, S.3
  • 9
    • 3042745625 scopus 로고    scopus 로고
    • Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture
    • Robinson C.M., Court-Brown C.M., McQueen M.M., and Wakefield A.E. Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture. J Bone Joint Surg 86A (2004) 1359-1365
    • (2004) J Bone Joint Surg , vol.86 A , pp. 1359-1365
    • Robinson, C.M.1    Court-Brown, C.M.2    McQueen, M.M.3    Wakefield, A.E.4
  • 10
    • 0032854198 scopus 로고    scopus 로고
    • Plate fixation of fresh displaced midshaft clavicle fractures
    • Shen W.J., Liu T.J., and Shen Y.S. Plate fixation of fresh displaced midshaft clavicle fractures. Injury 30 (1999) 497-500
    • (1999) Injury , vol.30 , pp. 497-500
    • Shen, W.J.1    Liu, T.J.2    Shen, Y.S.3
  • 11
    • 0002130847 scopus 로고    scopus 로고
    • Clavicular nonunion and malunion: evaluation and surgical management
    • Simpson N.S., and Jupiter J.B. Clavicular nonunion and malunion: evaluation and surgical management. J Am Acad Orthop Surg 4 (1996) 1-8
    • (1996) J Am Acad Orthop Surg , vol.4 , pp. 1-8
    • Simpson, N.S.1    Jupiter, J.B.2
  • 12
    • 0035079809 scopus 로고    scopus 로고
    • Midshaft fractures of the clavicle with a shortening of more than 2 cm predispose to nonunion
    • Wick M., Mu{double acute}ller E.J., Kollig E., and Muhr G. Midshaft fractures of the clavicle with a shortening of more than 2 cm predispose to nonunion. Arch Orthop Trauma Surg 121 (2001) 207-211
    • (2001) Arch Orthop Trauma Surg , vol.121 , pp. 207-211
    • Wick, M.1    Muller, E.J.2    Kollig, E.3    Muhr, G.4
  • 14
    • 70449094364 scopus 로고    scopus 로고
    • Biomechanical response of the human clavicle subjected to dynamic bending
    • Kemper A., Stitzel J., Gabler C., Duma S., and Matsuoka F. Biomechanical response of the human clavicle subjected to dynamic bending. Biomed Sci Instrum 42 (2006) 231-236
    • (2006) Biomed Sci Instrum , vol.42 , pp. 231-236
    • Kemper, A.1    Stitzel, J.2    Gabler, C.3    Duma, S.4    Matsuoka, F.5
  • 16
    • 0036704093 scopus 로고    scopus 로고
    • Open reduction and internal fixation of humeral nonunions: a biomechanical and clinical study
    • Rubel I.F., Kloen P., Campbell D., Schwartz M., Liew A., Myers E., et al. Open reduction and internal fixation of humeral nonunions: a biomechanical and clinical study. J Bone Joint Surg 84A (2002) 1315-1322
    • (2002) J Bone Joint Surg , vol.84 A , pp. 1315-1322
    • Rubel, I.F.1    Kloen, P.2    Campbell, D.3    Schwartz, M.4    Liew, A.5    Myers, E.6
  • 17
    • 0028197399 scopus 로고
    • The incidence of fractures of the clavicle
    • Nordqvist A., and Petersson C. The incidence of fractures of the clavicle. Clin Orthop Relat Res 300 (1994) 127-132
    • (1994) Clin Orthop Relat Res , vol.300 , pp. 127-132
    • Nordqvist, A.1    Petersson, C.2
  • 18
    • 42049088290 scopus 로고    scopus 로고
    • Biomechanical evaluation of clavicle fracture plating techniques: does a locking plate provide improved stability?
    • Celestre P., Robertson C., Mahar A., Oka R., Meunier M., and Schwartz A. Biomechanical evaluation of clavicle fracture plating techniques: does a locking plate provide improved stability?. J Orthop Trauma 22 (2008) 241-247
    • (2008) J Orthop Trauma , vol.22 , pp. 241-247
    • Celestre, P.1    Robertson, C.2    Mahar, A.3    Oka, R.4    Meunier, M.5    Schwartz, A.6
  • 19
    • 60649092513 scopus 로고    scopus 로고
    • Reconstruction plates for stabilization of mid-shaft clavicle fractures: differences between nonlocked and locked plates in two different positions
    • Robertson C., Celestre P., Mahar A., and Schwartz A. Reconstruction plates for stabilization of mid-shaft clavicle fractures: differences between nonlocked and locked plates in two different positions. J Shoulder Elbow Surg 18 (2009) 204-209
    • (2009) J Shoulder Elbow Surg , vol.18 , pp. 204-209
    • Robertson, C.1    Celestre, P.2    Mahar, A.3    Schwartz, A.4
  • 21
    • 0034204416 scopus 로고    scopus 로고
    • The clavicular fracture: a biomechanical study of the mechanism of clavicular fracture and modes of the fracture
    • Harnroongroj T., Tantikul C., and Keatkor S. The clavicular fracture: a biomechanical study of the mechanism of clavicular fracture and modes of the fracture. J Med Assoc Thai 83 (2000) 663-667
    • (2000) J Med Assoc Thai , vol.83 , pp. 663-667
    • Harnroongroj, T.1    Tantikul, C.2    Keatkor, S.3
  • 22
    • 0030200943 scopus 로고    scopus 로고
    • Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect
    • Harnroongroj T., and Vanadurongwan V. Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect. Clin Biomech (Bristol, Avon) 11 (1996) 290-294
    • (1996) Clin Biomech (Bristol, Avon) , vol.11 , pp. 290-294
    • Harnroongroj, T.1    Vanadurongwan, V.2
  • 23
    • 0041346511 scopus 로고    scopus 로고
    • Effects of plate location and selection on the stability of midshaft clavicle osteotomies: a biomechanical study
    • Iannotti M.R., Crosby L.A., Stafford P., Grayson G., and Goulet R. Effects of plate location and selection on the stability of midshaft clavicle osteotomies: a biomechanical study. J Shoulder Elbow Surg 11 (2002) 457-462
    • (2002) J Shoulder Elbow Surg , vol.11 , pp. 457-462
    • Iannotti, M.R.1    Crosby, L.A.2    Stafford, P.3    Grayson, G.4    Goulet, R.5
  • 24
    • 23844494146 scopus 로고    scopus 로고
    • Midshaft clavicular fractures: the role of operative treatment
    • Graves M.L., Geissler W.B., and Freeland A.E. Midshaft clavicular fractures: the role of operative treatment. Orthopedics 28 (2005) 761-764
    • (2005) Orthopedics , vol.28 , pp. 761-764
    • Graves, M.L.1    Geissler, W.B.2    Freeland, A.E.3