Volumn 25, Issue 2, 2010, Pages 71-78

Temperature Measurement in Patients Undergoing Colorectal Surgery and Gynecology Surgery: A Comparison of Esophageal Core, Temporal Artery, and Oral Methods

Author keywords

esophageal thermometry; oral thermometry; perioperative normothermia; temporal artery thermometry

Indexed keywords

ABDOMINAL SURGERY; ARTICLE; BODY TEMPERATURE; COMPARATIVE STUDY; ESOPHAGUS; GYNECOLOGIC SURGERY; HUMAN; METHODOLOGY; MONITORING; MOUTH; PERIOPERATIVE PERIOD; TEMPORAL ARTERY;

EID: 77949901334     PISSN: 10899472     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jopan.2010.01.006     Document Type: Article
Times cited : (32)

References (25)
  • 1
    • 84861274645 scopus 로고    scopus 로고
    • The Joint Commission, Available at:, Accessed December 13, 2007
    • The Joint Commission. Core measures. Available at: http://www.jointcommission.org. Accessed December 13, 2007.
    • Core measures
  • 3
    • 0036725179 scopus 로고    scopus 로고
    • Monitoring bladder temperatures in the OR
    • 481-484, 486
    • Fallis W.M. Monitoring bladder temperatures in the OR. AORN J 76 (2002) 467-476 481-484, 486
    • (2002) AORN J , vol.76 , pp. 467-476
    • Fallis, W.M.1
  • 4
    • 33750119733 scopus 로고    scopus 로고
    • Pulmonary artery catheters for adult patients in intensive care
    • Harvey S., Young D., Brampton W., et al. Pulmonary artery catheters for adult patients in intensive care. Cochrane Database Syst Rev 3 (2007)
    • (2007) Cochrane Database Syst Rev , vol.3
    • Harvey, S.1    Young, D.2    Brampton, W.3
  • 5
    • 33747191475 scopus 로고    scopus 로고
    • Accuracy of noninvasive core temperature measurement in acutely ill adults: The state of the science
    • Hooper V.D., and Andrews J.O. Accuracy of noninvasive core temperature measurement in acutely ill adults: The state of the science. Biol Res Nurs 8 (2006) 24-34
    • (2006) Biol Res Nurs , vol.8 , pp. 24-34
    • Hooper, V.D.1    Andrews, J.O.2
  • 6
    • 38449105002 scopus 로고    scopus 로고
    • Accuracy and precision of noninvasive temperature measurement in adult intensive care patients
    • Lawson L., Bridges E.J., Ballou I., et al. Accuracy and precision of noninvasive temperature measurement in adult intensive care patients. Am J Crit Care 16 (2007) 485-496
    • (2007) Am J Crit Care , vol.16 , pp. 485-496
    • Lawson, L.1    Bridges, E.J.2    Ballou, I.3
  • 7
    • 0033751668 scopus 로고    scopus 로고
    • "Deep-forehead" temperature correlates well with blood temperatures
    • Harioka T., Matsukawa T., Ozaki M., et al. "Deep-forehead" temperature correlates well with blood temperatures. Can J Anaesth 47 (2000) 980-983
    • (2000) Can J Anaesth , vol.47 , pp. 980-983
    • Harioka, T.1    Matsukawa, T.2    Ozaki, M.3
  • 8
    • 15844370553 scopus 로고    scopus 로고
    • Temporal scanner thermometry: A new method of core temperature estimation in ICU patients
    • Myny D., De Waele J., Defloor T., et al. Temporal scanner thermometry: A new method of core temperature estimation in ICU patients. Scott Med J 50 (2005) 15-18
    • (2005) Scott Med J , vol.50 , pp. 15-18
    • Myny, D.1    De Waele, J.2    Defloor, T.3
  • 9
    • 0036292261 scopus 로고    scopus 로고
    • Insufficiency in a new temporal-artery thermometer for adult and pediatric patients
    • Suleman M.I., Doufas A.G., Akca O., et al. Insufficiency in a new temporal-artery thermometer for adult and pediatric patients. Anesth Analg 95 (2002) 67-71
    • (2002) Anesth Analg , vol.95 , pp. 67-71
    • Suleman, M.I.1    Doufas, A.G.2    Akca, O.3
  • 10
    • 0028085738 scopus 로고
    • Determination of oral temperature accuracy in adult critical care patients who are orally intubated
    • Fallis W.M., Gupton A., and Kassum D. Determination of oral temperature accuracy in adult critical care patients who are orally intubated. Heart Lung 23 (1994) 300-307
    • (1994) Heart Lung , vol.23 , pp. 300-307
    • Fallis, W.M.1    Gupton, A.2    Kassum, D.3
  • 11
    • 0029246294 scopus 로고
    • Comparison of peripheral temperature measurements with core temperature
    • Henker R., and Coyne C. Comparison of peripheral temperature measurements with core temperature. AACN Clin Issues Adv Pract Acute Crit Care 6 (1995) 21-30
    • (1995) AACN Clin Issues Adv Pract Acute Crit Care , vol.6 , pp. 21-30
    • Henker, R.1    Coyne, C.2
  • 12
    • 6944222922 scopus 로고    scopus 로고
    • Temperature measurement in critical care adults: A comparison of thermometry and measurement routes
    • Smith L.S. Temperature measurement in critical care adults: A comparison of thermometry and measurement routes. Biol Res Nurs 6 (2004) 117-125
    • (2004) Biol Res Nurs , vol.6 , pp. 117-125
    • Smith, L.S.1
  • 13
    • 0034223069 scopus 로고    scopus 로고
    • Temperature measurement in critically ill adults: A comparison of tympanic and oral methods
    • Giuliano K.K., Giuliano A.J., Scott S.S., et al. Temperature measurement in critically ill adults: A comparison of tympanic and oral methods. Am J Crit Care 9 (2000) 254-261
    • (2000) Am J Crit Care , vol.9 , pp. 254-261
    • Giuliano, K.K.1    Giuliano, A.J.2    Scott, S.S.3
  • 14
    • 0028120250 scopus 로고
    • Accuracy of infrared ear thermometry and other temperature methods in adults
    • Erickson R.S., and Meyer L.T. Accuracy of infrared ear thermometry and other temperature methods in adults. Am J Crit Care 3 (1994) 40-54
    • (1994) Am J Crit Care , vol.3 , pp. 40-54
    • Erickson, R.S.1    Meyer, L.T.2
  • 15
    • 0029355651 scopus 로고
    • Agreement between measures of pulmonary artery and tympanic temperatures
    • Lattavo K., Britt J., and Dobal M. Agreement between measures of pulmonary artery and tympanic temperatures. Res Nurs Health 18 (1995) 365-370
    • (1995) Res Nurs Health , vol.18 , pp. 365-370
    • Lattavo, K.1    Britt, J.2    Dobal, M.3
  • 16
    • 0032735007 scopus 로고    scopus 로고
    • Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic, and oral methods
    • Giuliano K.K., Scott S.S., Elliot S., et al. Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic, and oral methods. Crit Care Med 27 (1999) 2188-2193
    • (1999) Crit Care Med , vol.27 , pp. 2188-2193
    • Giuliano, K.K.1    Scott, S.S.2    Elliot, S.3
  • 17
    • 0029339592 scopus 로고
    • A comparison of five methods of temperature measurement in febrile intensive care patients
    • Schmitz T., Bair N., Falk M., et al. A comparison of five methods of temperature measurement in febrile intensive care patients. Am J Crit Care 4 (1995) 286-292
    • (1995) Am J Crit Care , vol.4 , pp. 286-292
    • Schmitz, T.1    Bair, N.2    Falk, M.3
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 33845937103 scopus 로고    scopus 로고
    • Tympanic temperature measurements: Are they reliable in the critically ill? A clinical study of measures of agreement
    • Moran J.L., Peter J.V., Solomon P.J., et al. Tympanic temperature measurements: Are they reliable in the critically ill? A clinical study of measures of agreement. Crit Care Med 35 (2007) 155-164
    • (2007) Crit Care Med , vol.35 , pp. 155-164
    • Moran, J.L.1    Peter, J.V.2    Solomon, P.J.3
  • 23
    • 0026305913 scopus 로고
    • Axillary, tympanic, and esophageal temperature measurement: Descriptive comparisons in postanesthesia patients
    • Summers S. Axillary, tympanic, and esophageal temperature measurement: Descriptive comparisons in postanesthesia patients. J Post Anesth Nurs 6 (1991) 420-425
    • (1991) J Post Anesth Nurs , vol.6 , pp. 420-425
    • Summers, S.1
  • 24
    • 0031709718 scopus 로고    scopus 로고
    • Comparison of esophageal, rectal, axillary, bladder, tympanic, and pulmonary artery temperatures in children
    • Robinson J.L., Seal R.F., Spady D.W., et al. Comparison of esophageal, rectal, axillary, bladder, tympanic, and pulmonary artery temperatures in children. J Pediatr 133 (1998) 553-556
    • (1998) J Pediatr , vol.133 , pp. 553-556
    • Robinson, J.L.1    Seal, R.F.2    Spady, D.W.3
  • 25
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland J.M., and Altman D.G. Comparing methods of measurement: Why plotting difference against standard method is misleading. Lancet 346 (1995) 1085-1087
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.