메뉴 건너뛰기




Volumn 25, Issue 8, 2009, Pages 80-83

QCM based on flow system for cardiovascular disease

Author keywords

Acute myocardial infarction; Biosensor; Cardiac marker; Flow injection; Quartz Crystal microbalance

Indexed keywords

ACOUSTIC IMPEDANCE; ANTIBODIES; BIOMEDICAL ENGINEERING; BIOSENSORS; CARDIOLOGY; CHEMICAL DETECTION; CHLORINE COMPOUNDS; CRYSTALS; MEDICAL PHYSICS; NANOSYSTEMS; POLYVINYL CHLORIDES; QUARTZ; SIGNAL TRANSDUCTION;

EID: 77949878745     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03887-7_22     Document Type: Conference Paper
Times cited : (8)

References (8)
  • 1
    • 0026585297 scopus 로고
    • Sudden cardiac death: A comparative study of morphological, histochemical and biochemical methods
    • Hougen HP, Valenzuela A, Lachica E, Villanueva, E. (1992) Sudden cardiac death: a comparative study of morphological, histochemical and biochemical methods. Foren Sci Int. 52, 161-169.
    • (1992) Foren Sci Int , vol.52 , pp. 161-169
    • Hougen, H.P.1    Valenzuela, A.2    Lachica, E.3    Villanueva, E.4
  • 3
    • 0028864049 scopus 로고
    • Value of myoglobin, troponin T, and CK-MBmass in ruling out an acute myocardial infarction in the emergency room
    • De Winter RJ, Koster RW, Sturk A, Sanders GT. (1995) Value of myoglobin, troponin T, and CK-MBmass in ruling out an acute myocardial infarction in the emergency room. Circulation. 92, 3401-3407.
    • (1995) Circulation , vol.92 , pp. 3401-3407
    • De Winter, R.J.1    Koster, R.W.2    Sturk, A.3    Sanders, G.T.4
  • 4
    • 0023214007 scopus 로고    scopus 로고
    • B. Cummins, M.L. Auckland, P. Cummins. (1987) Am. Heart J. 113.1333-1344.
    • B. Cummins, M.L. Auckland, P. Cummins. (1987) Am. Heart J. 113.1333-1344.
  • 5
    • 3042820791 scopus 로고    scopus 로고
    • Monolithic miniaturized quartz microbalance array and its application to chemical sensor systems for liquids
    • August
    • J. Rabe, S. Buttgenbach, J. Schroder, and P. Hauptmann, "Monolithic miniaturized quartz microbalance array and its application to chemical sensor systems for liquids," IEEE Sensors Journal, Vol. 3, pp. 361-368, August 2003.
    • (2003) IEEE Sensors Journal , vol.3 , pp. 361-368
    • Rabe, J.1    Buttgenbach, S.2    Schroder, J.3    Hauptmann, P.4
  • 6
    • 27944495705 scopus 로고    scopus 로고
    • Quartz Crystal Microbalance (QCM) Sensor for Ammonia Gas using Clay/ Polyelectrolyte Layer-by-Layer Self-Assembly Film
    • October
    • Masashi Kikuchi, Katsuya Omori, and Seimei Shiratori, "Quartz Crystal Microbalance (QCM) Sensor for Ammonia Gas using Clay/ Polyelectrolyte Layer-by-Layer Self-Assembly Film," IEEE Sensors Proceedings 2004, vol. 2, pp. 718-721, October 2004.
    • (2004) IEEE Sensors Proceedings , vol.2 , pp. 718-721
    • Kikuchi, M.1    Omori, K.2    Shiratori, S.3
  • 7
    • 25144457710 scopus 로고    scopus 로고
    • Miniaturized QCM-based flow system for immunosensor application on liquid
    • April
    • M. Michalzik, R. Wilke, S. Buttgenbach, "Miniaturized QCM-based flow system for immunosensor application on liquid," Sensors and Actuators B, pp. 410-415, April 2005
    • (2005) Sensors and Actuators B , pp. 410-415
    • Michalzik, M.1    Wilke, R.2    Buttgenbach, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.