메뉴 건너뛰기




Volumn 25, Issue 7, 2009, Pages 634-637

Continuous SvO2 monitoring is reliable after on-pump cardiac surgery

Author keywords

Cardiac surgery; Hemodynamic monitoring; Mixed venous oxygen saturation; Pulmonary artery catheter

Indexed keywords

BIOMEDICAL ENGINEERING; BLOOD; BLOOD GAS ANALYSIS; CARDIOVASCULAR SURGERY; CATHETERS; HEART; MEDICAL PHYSICS; OXYGEN; PATIENT MONITORING;

EID: 77949840220     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03885-3_176     Document Type: Conference Paper
Times cited : (2)

References (9)
  • 1
    • 0343674564 scopus 로고    scopus 로고
    • A Prospective, Randomized Study of Goal-Oriented Hemodynamic Therapy in Cardiac Surgical Patients
    • Pölönen P, Ruokonen E, Hippeläinen M, Pöyhönen M, Takala J (2000) A Prospective, Randomized Study of Goal-Oriented Hemodynamic Therapy in Cardiac Surgical Patients. Anesth Analg 90:1052-1059
    • (2000) Anesth Analg , vol.90 , pp. 1052-1059
    • Pölönen, P.1    Ruokonen, E.2    Hippeläinen, M.3    Pöyhönen, M.4    Takala, J.5
  • 2
    • 34547769825 scopus 로고    scopus 로고
    • Guidelines for intensive care in cardiac surgery patients: Haemodynamic monitoring and cardiocirculatory treatment guidelines of the German Society for Thoracic and Cardiovascular Surgery and the German Society of Anaesthesiology and Intensive Care Medicine
    • Carl L, Alms A, Braun J et al. (2007) Guidelines for intensive care in cardiac surgery patients: haemodynamic monitoring and cardiocirculatory treatment guidelines of the German Society for Thoracic and Cardiovascular Surgery and the German Society of Anaesthesiology and Intensive Care Medicine. Thorac Cardiovasc Surg 55:130-148
    • (2007) Thorac Cardiovasc Surg , vol.55 , pp. 130-148
    • Carl, L.1    Alms, A.2    Braun, J.3
  • 3
    • 38749086820 scopus 로고    scopus 로고
    • Comparison of central venous to mixed venous oxygen saturation in patients with low cardiac index and filling pressures after coronary artery surgery
    • Yazigi A, El Khoury C, Jebara S, Hadda F, Hayeck G, Sleilaty G (2008) Comparison of central venous to mixed venous oxygen saturation in patients with low cardiac index and filling pressures after coronary artery surgery. J Cardiothorac Vasc Anesth. 22:77-83
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 77-83
    • Yazigi, A.1    El Khoury, C.2    Jebara, S.3    Hadda, F.4    Hayeck, G.5    Sleilaty, G.6
  • 5
    • 56349116631 scopus 로고    scopus 로고
    • Central venous oxygen saturation cannot replace mixed venous saturation in patients undergoing cardiac surgery
    • Lorentzen AG, Lindskov C, Sloth E, Jakobsen CJ (2008) Central venous oxygen saturation cannot replace mixed venous saturation in patients undergoing cardiac surgery. J Cardiothorac Vasc Anesth 22:853-857
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 853-857
    • Lorentzen, A.G.1    Lindskov, C.2    Sloth, E.3    Jakobsen, C.J.4
  • 6
    • 3042742662 scopus 로고    scopus 로고
    • Continuous Svo2 measurements and co-oximetry are not interchangeable immediately after cardiopulmonary bypass
    • Bendjelid K, Schutz N, Suter PM, Romand JA (2004) Continuous Svo2 measurements and co-oximetry are not interchangeable immediately after cardiopulmonary bypass. Can J Anaesth. 51:610-5
    • (2004) Can J Anaesth , vol.51 , pp. 610-615
    • Bendjelid, K.1    Schutz, N.2    Suter, P.M.3    Romand, J.A.4
  • 7
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchly JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15:85-91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchly, J.A.2
  • 8
    • 45549095653 scopus 로고    scopus 로고
    • Sleutjes BTHM, Kemps HMC, Thijssen EJM,Van des Vosse FN, Schep Gof, Peters CH, Wijn PFF (2008) The reliability of continuous measurement of mixed venous oxygen saturation during exercise in patients with chronic heart failure. Eur J Appl Physiol 102:493-496
    • Sleutjes BTHM, Kemps HMC, Thijssen EJM,Van des Vosse FN, Schep Gof, Peters CH, Wijn PFF (2008) The reliability of continuous measurement of mixed venous oxygen saturation during exercise in patients with chronic heart failure. Eur J Appl Physiol 102:493-496
  • 9
    • 77949800715 scopus 로고    scopus 로고
    • Hemoximetry as the "gold standard"? Error assessment based on differences among identical blood gas analyzer devices of five manufacturers
    • Gehring H, Duembgen L, Peterlein M, Hagelberg S, Dibbelt L (2007) Hemoximetry as the "gold standard"? Error assessment based on differences among identical blood gas analyzer devices of five manufacturers. Anesth Analg 105:S24-30
    • (2007) Anesth Analg , vol.105
    • Gehring, H.1    Duembgen, L.2    Peterlein, M.3    Hagelberg, S.4    Dibbelt, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.