메뉴 건너뛰기




Volumn , Issue , 2009, Pages

On enhancing cardiac pulse measurements through thermal imaging

Author keywords

Pulse recovery; Thermal imaging; Tracking

Indexed keywords

CARDIAC PULSE; CLINICAL APPLICATION; COMPARATIVE EXPERIMENTS; DATA SETS; HEAT TRANSFER EFFECTS; INSTANTANEOUS MEASUREMENT; MEASUREMENT ACCURACY; NOISE REDUCTION ALGORITHMS; PARAMETER OPTIMIZATION; PHYSIOLOGICAL FUNCTIONS; PHYSIOLOGICAL SIGNALS; PULSE MEASUREMENTS; PULSE PROPAGATION; THERMAL IMAGING;

EID: 77949590223     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ITAB.2009.5394334     Document Type: Conference Paper
Times cited : (10)

References (11)
  • 3
    • 34948820628 scopus 로고    scopus 로고
    • Thermal imaging of the superficial temporal artery: An arterial pulse recovery model
    • S. Chekmenev, A. Farag, and E. Essock. Thermal imaging of the superficial temporal artery: An arterial pulse recovery model. CVPR, pages 1-6, 2007.
    • (2007) CVPR , pp. 1-6
    • Chekmenev, S.1    Farag, A.2    Essock, E.3
  • 6
    • 34447529106 scopus 로고    scopus 로고
    • Contact-free measurement of cardiac pulse based on the analysis of thermal imagery
    • August
    • M. Garbey, N. Sun, A. Merla, and I. Pavlidis. Contact-free measurement of cardiac pulse based on the analysis of thermal imagery. IEEE Trans. Biomed. Eng., 54(8):1418-1426, August 2007.
    • (2007) IEEE Trans. Biomed. Eng , vol.54 , Issue.8 , pp. 1418-1426
    • Garbey, M.1    Sun, N.2    Merla, A.3    Pavlidis, I.4
  • 7
    • 77949626706 scopus 로고    scopus 로고
    • A. C. Guyton. Textbook of medical physiology. 8th ed. Philadelphia, PA: Saunders, Unit 3, ch. 11, 1991.
    • A. C. Guyton. Textbook of medical physiology. 8th ed. Philadelphia, PA: Saunders, Unit 3, ch. 11, 1991.
  • 8
    • 77949590676 scopus 로고    scopus 로고
    • I. S. Inc. Available: http://www.indigosystems.com. Goleta, California [Online].
    • I. S. Inc. Available: http://www.indigosystems.com. Goleta, California [Online].
  • 9
    • 0036667793 scopus 로고    scopus 로고
    • Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
    • S. Loukogeorgakis, R. Dawson, N. Phillips, C. Martyn, and S. Greenwald. Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method. Physiol. Meas., 23:581-596, 2002.
    • (2002) Physiol. Meas , vol.23 , pp. 581-596
    • Loukogeorgakis, S.1    Dawson, R.2    Phillips, N.3    Martyn, C.4    Greenwald, S.5