메뉴 건너뛰기




Volumn 15, Issue 2, 2010, Pages

Photoacoustic microtomography using optical interferometric detection

Author keywords

Imaging; Interferometry; Inverse problems; Photoacoustics; Sensors

Indexed keywords

2-D WAVE; 3-D IMAGE; 3D IMAGING; BIOLOGICAL RESEARCH; FILTERED BACK PROJECTION; FREQUENCY DOMAIN ALGORITHM; HUMAN HAIR; IMAGING; IMAGING INTERFEROMETRY; INITIAL PRESSURE; INTERFEROMETRIC DETECTION; INVERSE RADON TRANSFORMS; ISOLATED MOUSE; LIGHT BEAM; LINE INTEGRALS; MICRO-TOMOGRAPHY; PHOTOACOUSTIC TOMOGRAPHY; PHOTOACOUSTICS; PROJECTION IMAGE; SCANNING MODE; TWO-STEP PROCESS; WATER BATHS;

EID: 77949527790     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3333547     Document Type: Article
Times cited : (53)

References (29)
  • 2
    • 0038586601 scopus 로고    scopus 로고
    • Ther-moacoustic computed tomography using a conventional linear trans-ducer array
    • R. A. Kruger, W. L. Riser, D. R. Reinecke, and G. A. Kruger, "Ther-moacoustic computed tomography using a conventional linear trans-ducer array," Med. Phys. 30, 856-860 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 856-860
    • Kruger, R.A.1    Riser, W.L.2    Reinecke, D.R.3    Kruger, G.A.4
  • 4
    • 33646434247 scopus 로고    scopus 로고
    • Photoacoustic imaging in biomedicine
    • M. H. Xu and L. V. Wang, "Photoacoustic imaging in biomedicine," Rev. Sci. Instrum, 77, 041101 (2006).
    • (2006) Rev. Sci. Instrum , vol.77 , pp. 041101
    • Xu, M.H.1    Wang, L.V.2
  • 5
    • 33645796931 scopus 로고    scopus 로고
    • Two-dimensional quantitative photoacoustic image reconstruction of ab-sorption distributions in scattering media by use of a simple iterative method
    • B. T. Cox, S. R. Arridge, K. P. Kostli, and P. C. Beard, "Two-dimensional quantitative photoacoustic image reconstruction of ab-sorption distributions in scattering media by use of a simple iterative method," Appl. Opt. 45, 1866-1875 (2006).
    • (2006) Appl. Opt. , vol.45 , pp. 1866-1875
    • Cox, B.T.1    Arridge, S.R.2    Kostli, K.P.3    Beard, P.C.4
  • 6
    • 34247327302 scopus 로고    scopus 로고
    • Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: Application to the measurement of blood oxygenation and haemoglobin concentration
    • J. Laufer, D. Delpy, C. Elwell, and P. Beard, "Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration," Phys. Med. Biol. 52, 141.-168 (2007).
    • (2007) Phys. Med. Biol. , vol.52 , pp. 141-168
    • Laufer, J.1    Delpy, D.2    Elwell, C.3    Beard, P.4
  • 7
    • 33746453851 scopus 로고    scopus 로고
    • Noninvasive imaging of hemoglobin concentration and oxygenation in the rat brain using high-resolution photoacoustic tomography
    • X. D. Wang, X. Y. Xie, G. N. Ku, and L. V. Wang, "Noninvasive imaging of hemoglobin concentration and oxygenation in the rat brain using high-resolution photoacoustic tomography," J. Biomed. Opt. 11, 024015 (2006).
    • (2006) J. Biomed. Opt. , vol.11 , pp. 024015
    • Wang, X.D.1    Xie, X.Y.2    Ku, G.N.3    Wang, L.V.4
  • 8
    • 33746152397 scopus 로고    scopus 로고
    • Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
    • H. F. Zhang, K. Maslov, G. Stoica, and L. V. Wang, "Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging," Nat. Biotechnol, 24, 848-851 (2006).
    • (2006) Nat. Biotechnol , vol.24 , pp. 848-851
    • Zhang, H.F.1    Maslov, K.2    Stoica, G.3    Wang, L.V.4
  • 9
    • 63649150845 scopus 로고    scopus 로고
    • In vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy
    • E. Z. Zhang, J. G. Laufer, R. B. Pedley, and P. C. Beard, "In vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy," Phys. Med. Biol. 54, 1035-1046 (2009).
    • (2009) Phys. Med. Biol. , vol.54 , pp. 1035-1046
    • Zhang, E.Z.1    Laufer, J.G.2    Pedley, R.B.3    Beard, P.C.4
  • 10
    • 1942516847 scopus 로고    scopus 로고
    • Recon-structions in limited-view thermoacoustic tomography
    • Y. Xu, L. V. Wang, G. Ambartsoumian, and P. Kuchment, "Recon-structions in limited-view thermoacoustic tomography," Med. Phys. 31, 724-733 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 724-733
    • Xu, Y.1    Wang, L.V.2    Ambartsoumian, G.3    Kuchment, P.4
  • 11
    • 28844438544 scopus 로고    scopus 로고
    • Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction
    • M. H. Xu and L. V. Wang, "Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction," Phys. Rev. E 67, 056605 (2003).
    • (2003) Phys. Rev. e , vol.67 , pp. 056605
    • Xu, M.H.1    Wang, L.V.2
  • 12
    • 34547361271 scopus 로고    scopus 로고
    • Photoacous-tic tomography using a Mach-Zehnder interferometer as acoustic line detector
    • G. Paltauf, R. Nuster, M. Haltmeier, and P. Burgholzer, "Photoacous-tic tomography using a Mach-Zehnder interferometer as acoustic line detector," Appl. Opt. 46, 3352-3358 (2007).
    • (2007) Appl. Opt. , vol.46 , pp. 3352-3358
    • Paltauf, G.1    Nuster, R.2    Haltmeier, M.3    Burgholzer, P.4
  • 14
    • 36749058033 scopus 로고    scopus 로고
    • Experimen-tal evaluation of reconstruction algorithms for limited view photoa-coustic tomography with line detectors
    • G. Paltauf, R. Nuster, M. Haltmeier, and P. Burgholzer, "Experimen-tal evaluation of reconstruction algorithms for limited view photoa-coustic tomography with line detectors," Inverse Probl. 23, S81-S94 (2007).
    • (2007) Inverse Probl. , vol.23
    • Paltauf, G.1    Nuster, R.2    Haltmeier, M.3    Burgholzer, P.4
  • 15
    • 36749018728 scopus 로고    scopus 로고
    • Temporal back-projection algorithms for photoacoustic tomography with, integrating line detectors
    • P. Burgholzer, J. Bauer-Marschallinger, H. Grun, M. Haltmeier, and G. Paltauf, "Temporal back-projection algorithms for photoacoustic tomography with, integrating line detectors," Inverse Probl. 23, 65-80 (2007).
    • (2007) Inverse Probl. , vol.23 , pp. 65-80
    • Burgholzer, P.1    Bauer-Marschallinger, J.2    Grun, H.3    Haltmeier, M.4    Paltauf, G.5
  • 16
    • 34247229649 scopus 로고    scopus 로고
    • Exact and approximative imaging methods for photoacoustic tomography using an arbitrary detection surface
    • P. Burgholzer, G. Matt, M. Haltmeier, and G. Paltauf, "Exact and approximative imaging methods for photoacoustic tomography using an arbitrary detection surface," Phys. Rev. E 75, 046706 (2007).
    • (2007) Phys. Rev. e , vol.75 , pp. 046706
    • Burgholzer, P.1    Matt, G.2    Haltmeier, M.3    Paltauf, G.4
  • 17
    • 69249222946 scopus 로고    scopus 로고
    • Weight factors for limited angle photoacoustic tomography
    • G. Paltauf, R. Nuster, and P. Burgholzer, "Weight factors for limited angle photoacoustic tomography," Phys. Med. Biol, 54, 3303-3314 (2009).
    • (2009) Phys. Med. Biol , vol.54 , pp. 3303-3314
    • Paltauf, G.1    Nuster, R.2    Burgholzer, P.3
  • 18
    • 0034912973 scopus 로고    scopus 로고
    • Temporal back-ward projection of optoacoustic pressure transients using Fourier transform methods
    • K. P. Kostli, M. Frenz, H. Bebie, and H. P. Weber, "Temporal back-ward projection of optoacoustic pressure transients using Fourier transform methods," Phys. Med. Biol. 46, 1863-1872 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1863-1872
    • Kostli, K.P.1    Frenz, M.2    Bebie, H.3    Weber, H.P.4
  • 19
    • 0036628476 scopus 로고    scopus 로고
    • Exact frequency-domain recon-struction for thermoacoustic tomography-I: Planar- Geometry
    • Y. Xu, D. Z. Feng, and L. V. Wang, "Exact frequency-domain recon-struction for thermoacoustic tomography-I: planar- geometry," IEEE Trans. Med, Imaging 21, 823-828 (2002).
    • (2002) IEEE Trans. Med, Imaging , vol.21 , pp. 823-828
    • Xu, Y.1    Feng, D.Z.2    Wang, L.V.3
  • 20
    • 0038137178 scopus 로고    scopus 로고
    • Two-dimensional photoacoustic imag-ing by use of Fourier-transform image reconstruction and a detector with an anisotropic response
    • K. P. Köstli and P. C. Beard, "Two-dimensional photoacoustic imag-ing by use of Fourier-transform image reconstruction and a detector with an anisotropic response," Appl, Opt. 42, 1899-1908 (2003).
    • (2003) Appl, Opt. , vol.42 , pp. 1899-1908
    • Köstli, K.P.1    Beard, P.C.2
  • 21
    • 34247338147 scopus 로고    scopus 로고
    • Three-dimensional photoacoustic tomography using acoustic line detec-tors
    • G. Paltauf, R. Nuster, P. Burgholzer, and M. Haltmeier, "Three-dimensional photoacoustic tomography using acoustic line detec-tors," Proc. SPIE 6437, 64370N (2007).
    • (2007) Proc. SPIE , vol.6437
    • Paltauf, G.1    Nuster, R.2    Burgholzer, P.3    Haltmeier, M.4
  • 23
    • 37649027576 scopus 로고    scopus 로고
    • Universal back-projection algorithm for photoacoustic computed tomography
    • M. H. Xu and L. V. Wang, "Universal back-projection algorithm for photoacoustic computed tomography," Phys. Rev. E 71, 016706 (2005).
    • (2005) Phys. Rev. e , vol.71 , pp. 016706
    • Xu, M.H.1    Wang, L.V.2
  • 24
    • 66549117497 scopus 로고    scopus 로고
    • Characterization of inte-grating ultrasound detectors for photoacoustic tomography
    • G. Paltauf, R. Nuster, and P. Burgholzer, "Characterization of inte-grating ultrasound detectors for photoacoustic tomography," J. Appl. Phys. 105, 102026 (2009).
    • (2009) J. Appl. Phys. , vol.105 , pp. 102026
    • Paltauf, G.1    Nuster, R.2    Burgholzer, P.3
  • 25
    • 77949524835 scopus 로고    scopus 로고
    • Influence of detecor bandwidth and detector size to the resolution of photoacoustic tomog-raphy
    • M. Haltmeier, O. Scherzer, and G. Zangerl, "Influence of detecor bandwidth and detector size to the resolution of photoacoustic tomog-raphy," Proc. MATHMOD 09, ARGESIM Report, Vol. 35, pp. 1736-1744 (2009).
    • (2009) Proc. MATHMOD 09, ARGESIM Report , vol.35 , pp. 1736-1744
    • Haltmeier, M.1    Scherzer, O.2    Zangerl, G.3
  • 27
    • 36248998898 scopus 로고    scopus 로고
    • Photoa-coustic tomography using a fiber based Fabry-Pérot interferometer as an integrating line detector and image reconstruction by model-based time reversal method
    • H. Gruen, G. Paltauf, M. Haltmeierc, and P. Burgholzer, "Photoa-coustic tomography using a fiber based Fabry-Pérot interferometer as an integrating line detector and image reconstruction by model-based time reversal method," Proc. SPIE 6631, 663107 (2007).
    • (2007) Proc. SPIE , vol.6631 , pp. 663107
    • Gruen, H.1    Paltauf, G.2    Haltmeierc, M.3    Burgholzer, P.4
  • 28
    • 77956642209 scopus 로고    scopus 로고
    • Three-dimensional photoacoustic imaging using fiber-based line detectors
    • 021306
    • H. Grün, T. Berer, P. Burgholzer, R. Nüster, and G. Paltauf, "Three-dimensional photoacoustic imaging using fiber-based line detectors," J. Biomed, Opt. 15, 021306 (2010).
    • J. Biomed, Opt. , vol.15 , pp. 2010
    • Grün, H.1    Berer, T.2    Burgholzer, P.3    Nüster, R.4    Paltauf, G.5
  • 29
    • 36248936625 scopus 로고    scopus 로고
    • Develop-ment of waveguide sensors for the application in photoacoustic to-mography
    • R. Nuster, G. Paltauf, H. Ditlbacher, and P. Burgholzer, "Develop-ment of waveguide sensors for the application in photoacoustic to-mography," Proc. SPIE 6631, 663106 (2007).
    • (2007) Proc. SPIE , vol.6631 , pp. 663106
    • Nuster, R.1    Paltauf, G.2    Ditlbacher, H.3    Burgholzer, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.