메뉴 건너뛰기




Volumn 47, Issue 4, 2010, Pages 335-339

Viral load assay sensitivity and low level viremia in HAART treated HIV patients

Author keywords

Cobas Ampliprep Cobas TaqMan HIV 1; HIV 1 RNA quantification; Low level viremia; Viral load assay sensitivity

Indexed keywords

ARTICLE; BIOASSAY; CONTROLLED STUDY; FALSE POSITIVE RESULT; HIGHLY ACTIVE ANTIRETROVIRAL THERAPY; HUMAN; HUMAN IMMUNODEFICIENCY VIRUS INFECTION; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; NONHUMAN; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; VIREMIA; VIRUS LOAD;

EID: 77949489461     PISSN: 13866532     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcv.2010.01.008     Document Type: Article
Times cited : (22)

References (9)
  • 1
    • 58749115755 scopus 로고    scopus 로고
    • Detection of HIV type 1 load by the Roche Cobas TaqMan assay in patients with viral loads previously undetectable by the Roche Cobas Amplicor Monitor
    • Gatanaga H., Tsukada K., Honda H., Tanuma J., Yazaki H., Watanabe T., et al. Detection of HIV type 1 load by the Roche Cobas TaqMan assay in patients with viral loads previously undetectable by the Roche Cobas Amplicor Monitor. Clinical Infectious Diseases 48 January (2) (2009) 260-262
    • (2009) Clinical Infectious Diseases , vol.48 , Issue.January 2 , pp. 260-262
    • Gatanaga, H.1    Tsukada, K.2    Honda, H.3    Tanuma, J.4    Yazaki, H.5    Watanabe, T.6
  • 2
    • 67651146871 scopus 로고    scopus 로고
    • Increased reporting of detectable plasma HIV-1 RNA levels at the critical threshold of 50 copies per milliliter with the Taqman assay in comparison to the Amplicor assay
    • Lima V., Harrigan R., and Montaner J.S.G. Increased reporting of detectable plasma HIV-1 RNA levels at the critical threshold of 50 copies per milliliter with the Taqman assay in comparison to the Amplicor assay. Journal of Acquired Immune Deficiency Syndromes 51 May (1) (2009) 3-6
    • (2009) Journal of Acquired Immune Deficiency Syndromes , vol.51 , Issue.May 1 , pp. 3-6
    • Lima, V.1    Harrigan, R.2    Montaner, J.S.G.3
  • 5
    • 0033609374 scopus 로고    scopus 로고
    • Persistence of HIV-1 transcription in peripheral-blood mononuclear cells in patients receiving potent antiretroviral therapy
    • Furtado M.R., Callaway D.S., Phair J.P., Kunstman K.J., Stanton J.L., Macken C.A., et al. Persistence of HIV-1 transcription in peripheral-blood mononuclear cells in patients receiving potent antiretroviral therapy. New England Journal of Medicine 340 May (21) (1999) 1614-1622
    • (1999) New England Journal of Medicine , vol.340 , Issue.May 21 , pp. 1614-1622
    • Furtado, M.R.1    Callaway, D.S.2    Phair, J.P.3    Kunstman, K.J.4    Stanton, J.L.5    Macken, C.A.6
  • 6
    • 54249156386 scopus 로고    scopus 로고
    • Increased detectability of plasma HIV-1 RNA after introduction of a new assay and altered specimen-processing procedures
    • Rebeiro P.F., Kheshti A., Bebawy S.S., Stinnette S.E., Erdem H., Tang Y.W., et al. Increased detectability of plasma HIV-1 RNA after introduction of a new assay and altered specimen-processing procedures. Clinical Infectious Diseases 47 November (10) (2008) 1354-1357
    • (2008) Clinical Infectious Diseases , vol.47 , Issue.November 10 , pp. 1354-1357
    • Rebeiro, P.F.1    Kheshti, A.2    Bebawy, S.S.3    Stinnette, S.E.4    Erdem, H.5    Tang, Y.W.6
  • 7
    • 51749121954 scopus 로고    scopus 로고
    • The significance of low-level plasma HIV viral load on COBAS TaqMan (R) HIV-1 assays for patients with undetectable plasma viral load on COBAS Amplicor (R) monitor version 1.5
    • Manavi K. The significance of low-level plasma HIV viral load on COBAS TaqMan (R) HIV-1 assays for patients with undetectable plasma viral load on COBAS Amplicor (R) monitor version 1.5. HIV Clinical Trials 9 July-August (4) (2008) 283-286
    • (2008) HIV Clinical Trials , vol.9 , Issue.July-August 4 , pp. 283-286
    • Manavi, K.1
  • 8
    • 36349034685 scopus 로고    scopus 로고
    • Comparative evaluation of the automated Roche TaqMan real-time quantitative human immunodeficiency virus type 1 RNA PCR assay and the Roche AMPLICOR version 1.5 conventional PCR assay
    • Oliver A.R., Pereira S.F., and Clark D.A. Comparative evaluation of the automated Roche TaqMan real-time quantitative human immunodeficiency virus type 1 RNA PCR assay and the Roche AMPLICOR version 1.5 conventional PCR assay. Journal of Clinical Microbiology 45 November (11) (2007) 3616-3619
    • (2007) Journal of Clinical Microbiology , vol.45 , Issue.November 11 , pp. 3616-3619
    • Oliver, A.R.1    Pereira, S.F.2    Clark, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.