-
1
-
-
0025321429
-
The future of hip fractures in the United States: Numbers, costs, and potential effects of postmenopausal estrogen
-
Cummings SR, Rubin SM, Black D. The future of hip fractures in the United States: Numbers, costs, and potential effects of postmenopausal estrogen. Clin Orthop 1990, 252:163-166.
-
(1990)
Clin Orthop
, vol.252
, pp. 163-166
-
-
Cummings, S.R.1
Rubin, S.M.2
Black, D.3
-
2
-
-
0020562697
-
The increasing incidence of fractures of the proximal femur: an orthopaedic epidemic
-
10.1016/S0140-6736(83)92358-9, 6134183
-
Wallace WA. The increasing incidence of fractures of the proximal femur: an orthopaedic epidemic. Lancet 1983, 1413-4. 10.1016/S0140-6736(83)92358-9, 6134183.
-
(1983)
Lancet
, pp. 1413-1414
-
-
Wallace, W.A.1
-
3
-
-
0019305579
-
The sliding compression screw - today's best answer for stabilization of intertrochanteric hip fractures
-
Doppelt SH. The sliding compression screw - today's best answer for stabilization of intertrochanteric hip fractures. OrthopClin North Am 1980, 11:507-23.
-
(1980)
OrthopClin North Am
, vol.11
, pp. 507-523
-
-
Doppelt, S.H.1
-
4
-
-
0018975995
-
Sliding screw fixation for proximal femoralfractures
-
Waddell JP. Sliding screw fixation for proximal femoralfractures. Orthop Clin North Am 1980, 11:607-22.
-
(1980)
Orthop Clin North Am
, vol.11
, pp. 607-622
-
-
Waddell, J.P.1
-
5
-
-
0020076988
-
Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation
-
Wolfgang GL, Bryant MH, O'Neill JP. Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation. Clin Orthop 1982, 163:148-58.
-
(1982)
Clin Orthop
, vol.163
, pp. 148-158
-
-
Wolfgang, G.L.1
Bryant, M.H.2
O'Neill, J.P.3
-
6
-
-
17144467492
-
Reverse obliquity fractures of the intertrochanteric region of the femur
-
Haidukewych GJ, Israel TA, Berry DJ. Reverse obliquity fractures of the intertrochanteric region of the femur. J Bone Joint Surg Am 2001, 83:643-650.
-
(2001)
J Bone Joint Surg Am
, vol.83
, pp. 643-650
-
-
Haidukewych, G.J.1
Israel, T.A.2
Berry, D.J.3
-
7
-
-
0037236194
-
Slotted intramedullary hip screw nails reduce proximal mechanical unloading
-
10.1097/00003086-200301000-00027, 12579017
-
Hardy DC, Drossos K. Slotted intramedullary hip screw nails reduce proximal mechanical unloading. Clin Orthop Relat Res 2003, (406):176-84. 10.1097/00003086-200301000-00027, 12579017.
-
(2003)
Clin Orthop Relat Res
, Issue.406
, pp. 176-184
-
-
Hardy, D.C.1
Drossos, K.2
-
8
-
-
0032059046
-
Intramedullary fixation of high subtrochanteric femoral fractures: A study comparing two implant designs, the Gamma nail and the intramedullary hip screw
-
10.1097/00005131-199805000-00006, 9619459
-
Rantanen J, Aro HT. Intramedullary fixation of high subtrochanteric femoral fractures: A study comparing two implant designs, the Gamma nail and the intramedullary hip screw. J Orthop Trauma 1998, 12:249-252. 10.1097/00005131-199805000-00006, 9619459.
-
(1998)
J Orthop Trauma
, vol.12
, pp. 249-252
-
-
Rantanen, J.1
Aro, H.T.2
-
9
-
-
84945749833
-
The treatment of trochanteric fractures of thefemur
-
Evans EM. The treatment of trochanteric fractures of thefemur. J Bone Joint Surg Br 1949, 31:190-203.
-
(1949)
J Bone Joint Surg Br
, vol.31
, pp. 190-203
-
-
Evans, E.M.1
-
10
-
-
0018931431
-
Classification of trochantericfractures
-
Jensen JS. Classification of trochantericfractures. Acta Orthop Scand 1980, 51:803-10.
-
(1980)
Acta Orthop Scand
, vol.51
, pp. 803-810
-
-
Jensen, J.S.1
-
11
-
-
0027260707
-
A new mobility score for predicting mortality after hip fracture
-
Parker MJ, Palmer CR. A new mobility score for predicting mortality after hip fracture. J Bone Joint Surg [Br] 1993, 75-B:797-8.
-
(1993)
J Bone Joint Surg [Br]
, vol.75 B
, pp. 797-798
-
-
Parker, M.J.1
Palmer, C.R.2
-
12
-
-
33645286249
-
Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures
-
10.1007/s00264-005-0028-0, 2532072, 16496147
-
Jones W, Johnston P, Parker M. Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures. Int Orthop 2006, 30:69-78. 10.1007/s00264-005-0028-0, 2532072, 16496147.
-
(2006)
Int Orthop
, vol.30
, pp. 69-78
-
-
Jones, W.1
Johnston, P.2
Parker, M.3
-
13
-
-
33846807803
-
Intramedullary fixation of intertrochanteric hip fractures: a comparison of two implant designs
-
10.1007/s00264-006-0128-5, 2267541, 16736148
-
Efstathopoulos NE, Nikolaou VS, Lazarettos T. Intramedullary fixation of intertrochanteric hip fractures: a comparison of two implant designs. Int Orthop 2007, 31:71-76. 10.1007/s00264-006-0128-5, 2267541, 16736148.
-
(2007)
Int Orthop
, vol.31
, pp. 71-76
-
-
Efstathopoulos, N.E.1
Nikolaou, V.S.2
Lazarettos, T.3
-
14
-
-
84921622711
-
Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults
-
Parker MJ, Handoll H. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Revi 2005,
-
(2005)
Cochrane Database Syst Revi
-
-
Parker, M.J.1
Handoll, H.2
-
15
-
-
0033034509
-
The AO/ASIF-proximal femoral nail (PFN): A new device for the treatment of unstable proximal femoral fractures
-
10.1016/S0020-1383(99)00091-1, 10505125
-
Simmermacher RK, Bosch AM, Werken C. The AO/ASIF-proximal femoral nail (PFN): A new device for the treatment of unstable proximal femoral fractures. Injury 1999, 30:327-332. 10.1016/S0020-1383(99)00091-1, 10505125.
-
(1999)
Injury
, vol.30
, pp. 327-332
-
-
Simmermacher, R.K.1
Bosch, A.M.2
Werken, C.3
-
16
-
-
0016256853
-
Stable fixation of intertrochanteric fractures: A biomechanical evaluation
-
Kaufer H, Matthews LS, Sonstegard D. Stable fixation of intertrochanteric fractures: A biomechanical evaluation. J Bone Joint Surg Am 1974, 56:899-907.
-
(1974)
J Bone Joint Surg Am
, vol.56
, pp. 899-907
-
-
Kaufer, H.1
Matthews, L.S.2
Sonstegard, D.3
-
17
-
-
0029012764
-
The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
-
Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 1995, 77:1058-1064.
-
(1995)
J Bone Joint Surg Am
, vol.77
, pp. 1058-1064
-
-
Baumgaertner, M.R.1
Curtin, S.L.2
Lindskog, D.M.3
Keggi, J.M.4
-
18
-
-
0025944925
-
Treatment of the unstable intertrochanteric fracture. Effect of the placement of the screw, its angle of insertion, and osteotomy
-
Den Hartog BD, Bartal E, Cooke F. Treatment of the unstable intertrochanteric fracture. Effect of the placement of the screw, its angle of insertion, and osteotomy. J Bone Joint Surg Am 1991, 73(5):726-33.
-
(1991)
J Bone Joint Surg Am
, vol.73
, Issue.5
, pp. 726-733
-
-
Den Hartog, B.D.1
Bartal, E.2
Cooke, F.3
-
19
-
-
0024439116
-
Axial loading studies of unstable intertrochanteric fractures of the femur
-
Apel DM, Patwardhan A, Pinzur MS, Dobozi WR. Axial loading studies of unstable intertrochanteric fractures of the femur. Clin Orthop 1989, 246:156-164.
-
(1989)
Clin Orthop
, vol.246
, pp. 156-164
-
-
Apel, D.M.1
Patwardhan, A.2
Pinzur, M.S.3
Dobozi, W.R.4
-
20
-
-
0031754784
-
Forces required initiating sliding in second-generation intramedullary nails
-
Loch DA, Kyle RF, Bechtold JE, Kane M, Anderson K. Forces required initiating sliding in second-generation intramedullary nails. J Bone Joint Surg Am 1998, 80(11):1626-31.
-
(1998)
J Bone Joint Surg Am
, vol.80
, Issue.11
, pp. 1626-1631
-
-
Loch, D.A.1
Kyle, R.F.2
Bechtold, J.E.3
Kane, M.4
Anderson, K.5
-
21
-
-
59649100290
-
Proximal femoral nail failures in extracapsular fractures of the hip
-
Ballal MSG, Emms N, Ramakrishnan M, Thomas G. Proximal femoral nail failures in extracapsular fractures of the hip. Journal of Orthopaedic Surgery 2008, 16(2):146-9.
-
(2008)
Journal of Orthopaedic Surgery
, vol.16
, Issue.2
, pp. 146-149
-
-
Ballal, M.S.G.1
Emms, N.2
Ramakrishnan, M.3
Thomas, G.4
-
22
-
-
42149167250
-
The treatment of stable and unstable proximal femoral fractures with a new trochanteric nail: results of a multicentre study with the Veronail
-
Lavini Franco ZL, Renzi-Brivio ZR, Aulisa Z. The treatment of stable and unstable proximal femoral fractures with a new trochanteric nail: results of a multicentre study with the Veronail. Strat Traum Limb Recon 2008, 3:15-22.
-
(2008)
Strat Traum Limb Recon
, vol.3
, pp. 15-22
-
-
Lavini Franco, Z.L.1
Renzi-Brivio, Z.R.2
Aulisa, Z.3
-
23
-
-
44449121970
-
Proximal femoral nail for treatment of trochanteric femoral fractures
-
Morihara T. Proximal femoral nail for treatment of trochanteric femoral fractures. Journal of Orthopaedic Surgery 2007, 15(3):273-7.
-
(2007)
Journal of Orthopaedic Surgery
, vol.15
, Issue.3
, pp. 273-277
-
-
Morihara, T.1
-
24
-
-
0026344705
-
Early experience with the Gamma interlocking nail for peritrochanteric fractures of the proximal femur
-
10.1097/00005373-199112000-00015, 1749038
-
Lindsey RW, Teal P, Probe BA, Rhoads D, Davenport S, Schauder K. Early experience with the Gamma interlocking nail for peritrochanteric fractures of the proximal femur. J Trauma 1991, 31:1649-58. 10.1097/00005373-199112000-00015, 1749038.
-
(1991)
J Trauma
, vol.31
, pp. 1649-1658
-
-
Lindsey, R.W.1
Teal, P.2
Probe, B.A.3
Rhoads, D.4
Davenport, S.5
Schauder, K.6
-
25
-
-
0025924658
-
Bone weakness after the removal of plates and screws: cortical atrophy or screw holes?
-
Rosson J, Egan J, Shearer J, Monro P. Bone weakness after the removal of plates and screws: cortical atrophy or screw holes?. J Bone Joint Surg [Br] 1991, 73-B:283-6.
-
(1991)
J Bone Joint Surg [Br]
, vol.73 B
, pp. 283-286
-
-
Rosson, J.1
Egan, J.2
Shearer, J.3
Monro, P.4
-
26
-
-
0028920150
-
Prevention of fracture at the distal locking site of the gamma nail a biomechanical study
-
Lacroix H, Arwert H, Snijders CJ. Prevention of fracture at the distal locking site of the gamma nail a biomechanical study. J Bone Joint Surg [Br] 1995, 77-B:274-6.
-
(1995)
J Bone Joint Surg [Br]
, vol.77 B
, pp. 274-276
-
-
Lacroix, H.1
Arwert, H.2
Snijders, C.J.3
-
27
-
-
0034953649
-
More postoperative femoral fractures with the Gamma nail than the sliding screw plate in the treatment of trochanteric fractures
-
Osnes EK, Lofthus CM, Falch JA, Meyer HE, Stensvold I, Kristiansen IS. More postoperative femoral fractures with the Gamma nail than the sliding screw plate in the treatment of trochanteric fractures. Acta Orthop Scand 2001, 72:252-6.
-
(2001)
Acta Orthop Scand
, vol.72
, pp. 252-256
-
-
Osnes, E.K.1
Lofthus, C.M.2
Falch, J.A.3
Meyer, H.E.4
Stensvold, I.5
Kristiansen, I.S.6
-
28
-
-
0031923801
-
Postoperative weight bearing after a fracture of the femoral neck or an intertrochanteric fracture
-
Koval KJ, Sala DA, Kummer FJ, Zuckerman JD. Postoperative weight bearing after a fracture of the femoral neck or an intertrochanteric fracture. J Bone Joint Surg Am 1998, 80:352-356.
-
(1998)
J Bone Joint Surg Am
, vol.80
, pp. 352-356
-
-
Koval, K.J.1
Sala, D.A.2
Kummer, F.J.3
Zuckerman, J.D.4
-
29
-
-
0028906576
-
Ambulatory ability after hip fracture: A prospective study in geriatric patients
-
Koval KJ, Skovron ML, Aharonoff GB, Meadows SE, Zuckerman JD. Ambulatory ability after hip fracture: A prospective study in geriatric patients. Clin Orthop 1995, 310:150-159.
-
(1995)
Clin Orthop
, vol.310
, pp. 150-159
-
-
Koval, K.J.1
Skovron, M.L.2
Aharonoff, G.B.3
Meadows, S.E.4
Zuckerman, J.D.5
-
30
-
-
0026410952
-
How predictable is rehabilitation after hip fracture? A prospective study of 134 patients
-
Sluijs JA, Walenkamp GHIM. How predictable is rehabilitation after hip fracture? A prospective study of 134 patients. Acta Orthop Scand 1991, 62:567-572.
-
(1991)
Acta Orthop Scand
, vol.62
, pp. 567-572
-
-
Sluijs, J.A.1
Walenkamp, G.H.I.M.2
|