3
-
-
77949453404
-
-
homepage at
-
Polar homepage at http://www.polar.fi/en/
-
Polar
-
-
-
5
-
-
77949449808
-
-
homepage at
-
Sensatex homepage at http://www.sensatex.com/
-
-
-
-
6
-
-
77949447097
-
-
at
-
Vital Jacket at http://www.vitaljacket.com
-
Vital Jacket
-
-
-
7
-
-
34250188136
-
Accuracy of the LifeShirt (Vivometrics) in the detection of cardiac rhythms
-
Keri J. Heilman S.W. P. (2007) Accuracy of the LifeShirt (Vivometrics) in the detection of cardiac rhythms. Biological Psychology 75:300305.
-
(2007)
Biological Psychology
, vol.75
, pp. 300305
-
-
Keri, J.1
Heilman, S.W.P.2
-
8
-
-
42949157345
-
Smart Vest: Wearable multi-parameter remote physiological monitoring system
-
Pandian P. S, Mohanavelu K, Safeer K. P, et al. (2008) Smart Vest: wearable multi-parameter remote physiological monitoring system. Med Eng Phys 30:466-477.
-
(2008)
Med Eng Phys
, vol.30
, pp. 466-477
-
-
Pandian, P.S.1
Mohanavelu, K.2
Safeer, K.P.3
-
9
-
-
33846896697
-
MagIC System: A New Textile-Based Wearable Device for Biological Signal Monitoring. Applicability in Daily Life and Clinical Setting. Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005
-
Rienzo M. D, Rizzo F, Parati G, Brambilla G, Ferratini M, Castiglioni P. (2005) MagIC System: a New Textile-Based Wearable Device for Biological Signal Monitoring. Applicability in Daily Life and Clinical Setting. Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the, :7167-7169.
-
(2005)
27th Annual International Conference of the
, pp. 7167-7169
-
-
Rienzo, M.D.1
Rizzo, F.2
Parati, G.3
Brambilla, G.4
Ferratini, M.5
Castiglioni, P.6
-
12
-
-
0022543938
-
Structural and functional changes of normal aging skin
-
Oct;
-
Fenske N. (1986) Structural and functional changes of normal aging skin. J Am Acad Dermatol. Oct; 15.
-
(1986)
J Am Acad Dermatol
, pp. 15
-
-
Fenske, N.1
-
13
-
-
61849167896
-
Reliable Motion Artifact Detection for ECG Monitoring Systems with Dry Electrodes
-
Ottenbacher J, Kirst M, Jatobá L, Huflejt M, Großmann U, Stork W. (2008) Reliable Motion Artifact Detection for ECG Monitoring Systems with Dry Electrodes. Conf Proc IEEE Eng Med Biol Soc 2008:1695-1698.
-
(2008)
Conf Proc IEEE Eng Med Biol Soc 2008
, pp. 1695-1698
-
-
Ottenbacher, J.1
Kirst, M.2
Jatobá, L.3
Huflejt, M.4
Großmann, U.5
Stork, W.6
-
14
-
-
57649180485
-
Flexible dry surface-electrodes for ECG long-term monitoring. Engineering in Medicine and Biology Society, 2007. EMBS 2007
-
Lyon
-
Hoffmann K. P, Ruff R. (2007) Flexible dry surface-electrodes for ECG long-term monitoring. Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE, Lyon, :5739-5742.
-
(2007)
29th Annual International Conference of the IEEE
, pp. 5739-5742
-
-
Hoffmann, K.P.1
Ruff, R.2
-
15
-
-
77949437625
-
-
ELITEX at http://www.imbut.de/de/produkte/spezialfaeden
-
ELITEX at http://www.imbut.de/de/produkte/spezialfaeden
-
-
-
-
16
-
-
0024615772
-
Impulsive noise suppression and background normalization of electrocardiogram signals using morphological operators
-
Chu C.-H, Delp E. (1989) Impulsive noise suppression and background normalization of electrocardiogram signals using morphological operators. IEEE Transactions on Biomedical Engineering 36:262-273.
-
(1989)
IEEE Transactions on Biomedical Engineering
, vol.36
, pp. 262-273
-
-
Chu, C.-H.1
Delp, E.2
-
17
-
-
0036950331
-
Open source ECG analysis
-
Hamilton P. (2002) Open source ECG analysis. Computers in Cardiology, 29:101-104.
-
(2002)
Computers in Cardiology
, vol.29
, pp. 101-104
-
-
Hamilton, P.1
|