메뉴 건너뛰기




Volumn 43, Issue 6, 2010, Pages 949-959

Direct determination of Dy, Sm, Eu, Tm, and Yb in geological samples by slurry electrothermal vaporization inductively coupled plasma mass spectrometry

Author keywords

ETV ICP MS; Geological material; Rare earth elements

Indexed keywords


EID: 77949333724     PISSN: 00032719     EISSN: 1532236X     Source Type: Journal    
DOI: 10.1080/00032710903491062     Document Type: Article
Times cited : (15)

References (20)
  • 1
    • 0037427644 scopus 로고    scopus 로고
    • Solid phase extraction for analysis of biogenic carbonates by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS): An investigation of rare earth elements signatures in otolith microchemistry
    • Arslan, Z., and A. J. Paulson. 2003. Solid phase extraction for analysis of biogenic carbonates by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS): an investigation of rare earth elements signatures in otolith microchemistry. Anal. Chim. Acta 476: 1-13.
    • (2003) Anal. Chim. Acta , vol.476 , pp. 1-13
    • Arslan, Z.1    Paulson, A.J.2
  • 2
    • 84972959038 scopus 로고
    • Electrothermal vaporization for sample introduction in plasma source spectrometry
    • Carey, J. M., and J. A. Caruso. 1992. Electrothermal vaporization for sample introduction in plasma source spectrometry. Crit. Rev. Anal. Chem. 23: 397-439.
    • (1992) Crit. Rev. Anal. Chem , vol.23 , pp. 397-439
    • Carey, J.M.1    Caruso, J.A.2
  • 3
    • 0032119749 scopus 로고    scopus 로고
    • Determination of arsenic, selenium and mercury in fish samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry
    • Chen, S. F., and S. J. Jiang. 1998. Determination of arsenic, selenium and mercury in fish samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 13: 673-677.
    • (1998) J. Anal. At. Spectrom , vol.13 , pp. 673-677
    • Chen, S.F.1    Jiang, S.J.2
  • 4
    • 33745574440 scopus 로고
    • Review of solid sample introduction for plasma spectrometry and a comparison of results for laser ablation, electrothermal vaporization, and slurry nebulization
    • Darke, S. A., and J. F. Tyson. 1994. Review of solid sample introduction for plasma spectrometry and a comparison of results for laser ablation, electrothermal vaporization, and slurry nebulization. Microchem. J. 50: 310-336.
    • (1994) Microchem. J , vol.50 , pp. 310-336
    • Darke, S.A.1    Tyson, J.F.2
  • 6
    • 0026897540 scopus 로고
    • The role of chemical modifiers in analyte transport loss interferences with electrothermal vaporization ICP-mass spectrometry
    • Ediger, R. D., and S. A. Beres. 1992. The role of chemical modifiers in analyte transport loss interferences with electrothermal vaporization ICP-mass spectrometry. Spectrochim. Acta B 47: 907-922.
    • (1992) Spectrochim. Acta B , vol.47 , pp. 907-922
    • Ediger, R.D.1    Beres, S.A.2
  • 7
    • 0008672382 scopus 로고
    • Mechanism of vaporization of yttrium and rare earth elements in eletrothermal vaporization inductively coupled plasma-mass spectrometry
    • Goltz, D. M., D. C. Grégoire, and C. L. Chakrabarti. 1995. Mechanism of vaporization of yttrium and rare earth elements in eletrothermal vaporization inductively coupled plasma-mass spectrometry. Spectrochim. Acta B 50: 1365-1382.
    • (1995) Spectrochim. Acta B , vol.50 , pp. 1365-1382
    • Goltz, D.M.1    Grégoire, D.C.2    Chakrabarti, C.L.3
  • 9
    • 0029511713 scopus 로고
    • Trace analysis of single zircons for rare-earth elements, U and Th by electrothermal vaporization- inductively coupled plasma-mass spectrometry (ETV-ICP-MS)
    • Grégoire, D. C., K. M. Ansdell, D. M. Goltz, and C. L. Chakrabarti. 1995. Trace analysis of single zircons for rare-earth elements, U and Th by electrothermal vaporization- inductively coupled plasma-mass spectrometry (ETV-ICP-MS). Chem. Geol. 124: 91-99.
    • (1995) Chem. Geol , vol.124 , pp. 91-99
    • Grégoire, D.C.1    Ansdell, K.M.2    Goltz, D.M.3    Chakrabarti, C.L.4
  • 10
    • 0343953351 scopus 로고    scopus 로고
    • Analyte transport efficiency with electrothermal vaporization inductively coupled plasma mass spectrometry
    • Grégoire, D. C., and R. E. Sturgeon. 1999. Analyte transport efficiency with electrothermal vaporization inductively coupled plasma mass spectrometry. Spectrochim. Acta B 54: 773-786.
    • (1999) Spectrochim. Acta B , vol.54 , pp. 773-786
    • Grégoire, D.C.1    Sturgeon, R.E.2
  • 12
    • 13444306289 scopus 로고    scopus 로고
    • Electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of trace amount of lanthanides and yttrium in soil with polytetrafluroethylene emulsion as a chemical modifier
    • He, M., B. Hu, and Z. C. Jiang. 2005. Electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of trace amount of lanthanides and yttrium in soil with polytetrafluroethylene emulsion as a chemical modifier. Anal. Chim. Acta 530: 105-112.
    • (2005) Anal. Chim. Acta , vol.530 , pp. 105-112
    • He, M.1    Hu, B.2    Jiang, Z.C.3
  • 13
    • 84996337082 scopus 로고
    • A new method for determination of rare earth elements vaporized in graphite-furnace with a polytetrafluoroethylene slurry fluorinating reagent by inductively coupled plasma atomic emission-spectrometry
    • Huang, M., Z. C. Jiang, and Y. Zeng. 1991. A new method for determination of rare earth elements vaporized in graphite-furnace with a polytetrafluoroethylene slurry fluorinating reagent by inductively coupled plasma atomic emission-spectrometry. Anal. Sciences 7: 773-778.
    • (1991) Anal. Sciences , vol.7 , pp. 773-778
    • Huang, M.1    Jiang, Z.C.2    Zeng, Y.3
  • 14
    • 0002815840 scopus 로고
    • Determination of rare earth elements in geological samples by inductively coupled plasma mass spectrometry
    • Jarvis, K. E. 1989. Determination of rare earth elements in geological samples by inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 4: 563-570.
    • (1989) J. Anal. At. Spectrom , vol.4 , pp. 563-570
    • Jarvis, K.E.1
  • 15
    • 0031250784 scopus 로고    scopus 로고
    • Determination of U and Th at ultra-trace levels by isotope dilution inductively coupled plasma mass spectrometry using a geyser-type ultrasonic nebulizer: Application to geological samples
    • Joannon, S., P. Telouk, and C. Pin. 1997. Determination of U and Th at ultra-trace levels by isotope dilution inductively coupled plasma mass spectrometry using a geyser-type ultrasonic nebulizer: application to geological samples. Spectrochim. Acta B 52: 1783-1789.
    • (1997) Spectrochim. Acta B , vol.52 , pp. 1783-1789
    • Joannon, S.1    Telouk, P.2    Pin, C.3
  • 16
    • 0030212070 scopus 로고    scopus 로고
    • Determination of copper, cadmium and lead in sediment samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry
    • Liaw, M. J., and S. J. Jiang. 1996. Determination of copper, cadmium and lead in sediment samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 11: 555-560.
    • (1996) J. Anal. At. Spectrom , vol.11 , pp. 555-560
    • Liaw, M.J.1    Jiang, S.J.2
  • 17
    • 0031166714 scopus 로고    scopus 로고
    • Determination of mercury in fish samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry
    • Liaw, M. J., S. J. Jiang, and Y. C. Li. 1997. Determination of mercury in fish samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry. Spectrochim. Acta B 52: 779-785.
    • (1997) Spectrochim. Acta B , vol.52 , pp. 779-785
    • Liaw, M.J.1    Jiang, S.J.2    Li, Y.C.3
  • 19
    • 0002010627 scopus 로고    scopus 로고
    • Study of interferences from Na and Cl using ETV-ICP-MS
    • Pozebon, D., V. L. Dressler, and A. J. Curtius. 1998. Study of interferences from Na and Cl using ETV-ICP-MS. At. Spectrosc. 19: 80-88.
    • (1998) At. Spectrosc , vol.19 , pp. 80-88
    • Pozebon, D.1    Dressler, V.L.2    Curtius, A.J.3
  • 20
    • 26844515634 scopus 로고    scopus 로고
    • Direct determination of trace earth elements in ancient porcelain samples with slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry
    • Xiang, G., Z. Jiang, M. He, and B. Hu. 2005. Direct determination of trace earth elements in ancient porcelain samples with slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry. Spectrochim. Acta B 60: 1342-1348.
    • (2005) Spectrochim. Acta B , vol.60 , pp. 1342-1348
    • Xiang, G.1    Jiang, Z.2    He, M.3    Hu, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.