Intramedullary bone fragment obstructing passage of reaming guide wire with iatrogenic fractured tibia

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CASE REPORT; COMMINUTED FRACTURE; FRACTURE HEALING; GUIDE WIRE; HUMAN; IATROGENIC DISEASE; INTRAMEDULLARY NAILING; MALE; OBSTRUCTION; PEROPERATIVE COMPLICATION; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; REAMED INTERLOCKING INTRAMEDULLARY FIXATION; SCAPULA; SURGICAL TECHNIQUE; TIBIA FRACTURE; TIBIA SHAFT; TRAFFIC ACCIDENT; WEIGHT BEARING; IMPLANTATION; INSTRUMENTATION; KIRSCHNER WIRE; METHODOLOGY; OSTEOSYNTHESIS;

EID: 77949308257     PISSN: 01477447     EISSN: None     Source Type: Journal    
DOI: 10.3928/01477447-20100104-24     Document Type: Article
Times cited : (5)

References (2)
  • 1
    • 0022504244 scopus 로고
    • Treatment of tibial fractures by reaming and intramedullary nailing
    • Bone LB, Johnson KD. Treatment of tibial fractures by reaming and intramedullary nailing. J Bone Joint Surg Am. 1986; 68(6):877-887.
    • (1986) J Bone Joint Surg Am , vol.68 , Issue.6 , pp. 877-887
    • Bone, L.B.1    Johnson, K.D.2
  • 2
    • 38449108100 scopus 로고    scopus 로고
    • Intramedullary bone fragment preventing passage of reaming guide wire
    • Salamon M, Finkemeier CG. Intramedullary bone fragment preventing passage of reaming guide wire. Am J Orthop. 2007; 36(9):492-493.
    • (2007) Am J Orthop , vol.36 , Issue.9 , pp. 492-493
    • Salamon, M.1    Finkemeier, C.G.2