메뉴 건너뛰기




Volumn 42, Issue 5, 2010, Pages 598-604

Implementation of a method in EN ISO 13790 for calculating the utilisation factor taking into account different permeability levels of internal coverings

Author keywords

Building; Coverings; Energy; Implementation; Utilisation factor

Indexed keywords

BUILDING ENVELOPES; BUILDING OCCUPATIONS; BUILDING STRUCTURE; CLIMATIC CONDITIONS; COOLING ENERGY CONSUMPTION; ENERGY CONSUMPTION; ENVIRONMENTAL CONDITIONS; HEAT AND MASS TRANSFER; HEAT DEMANDS; IN-BUILDINGS; INDOOR MOISTURE; PERMEABILITY LEVELS; WEATHER CONDITIONS; WINTER SEASONS;

EID: 77949288564     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2009.10.030     Document Type: Article
Times cited : (25)

References (24)
  • 1
    • 85042719193 scopus 로고    scopus 로고
    • Energy estimating and modelling methods
    • ASHRAE, Atlanta (Chapter 19)
    • ASHRAE. Energy estimating and modelling methods. ASHRAE Handbook, Fundamentals, 2009 (2009), ASHRAE, Atlanta (Chapter 19)
    • (2009) ASHRAE Handbook, Fundamentals, 2009
    • ASHRAE1
  • 5
  • 6
    • 77949304953 scopus 로고    scopus 로고
    • Ministerio de Industria Turismo y Comercio, RITE, Murcia España
    • Ministerio de Industria Turismo y Comercio, RITE 2007: Reglamento de Instalaciones Térmicas en los Edificios, Murcia (España), 2007.
    • (2007) Reglamento de Instalaciones Térmicas en los Edificios
  • 7
    • 77949295809 scopus 로고    scopus 로고
    • Santiago de Compostela, A Coruña España, accessed August 2009
    • MeteoGalicia, Consellería de Medio Ambiente, Territorio e Infraestruturas Santiago de Compostela, A Coruña (España), http://www.meteogalicia.es/ (accessed August 2009).
    • Consellería de Medio Ambiente, Territorio e Infraestruturas
  • 8
    • 77949284198 scopus 로고    scopus 로고
    • ATECYR, DTIE 7.03, Entrada de datos a los programas LIDER y CALENER VyP Madrid (España), 2008.
    • ATECYR, DTIE 7.03, Entrada de datos a los programas LIDER y CALENER VyP Madrid (España), 2008.
  • 9
    • 33845810543 scopus 로고    scopus 로고
    • Performance of EN ISO 13790 utilisation factor heat demand calculation method in a cold climate
    • Jokisalo J., and Kurnitski J. Performance of EN ISO 13790 utilisation factor heat demand calculation method in a cold climate. Energy and Buildings 39 (2007) 236-247
    • (2007) Energy and Buildings , vol.39 , pp. 236-247
    • Jokisalo, J.1    Kurnitski, J.2
  • 10
    • 33847645006 scopus 로고    scopus 로고
    • Assessment of buildings cooling energy need through a quasi-steady state model: simplified correlation for gain-loss mismatch
    • Corrado V., and Fabrizio E. Assessment of buildings cooling energy need through a quasi-steady state model: simplified correlation for gain-loss mismatch. Energy and Buildings 39 (2007) 569-579
    • (2007) Energy and Buildings , vol.39 , pp. 569-579
    • Corrado, V.1    Fabrizio, E.2
  • 11
    • 84869833519 scopus 로고    scopus 로고
    • Building energy performance assessment through simplified models: application of the ISO 13790 quasi-steady state method
    • Corrado V., Mechri H.E., and Fabrizio E. Building energy performance assessment through simplified models: application of the ISO 13790 quasi-steady state method. Proceedings of Building Simulation (2007)
    • (2007) Proceedings of Building Simulation
    • Corrado, V.1    Mechri, H.E.2    Fabrizio, E.3
  • 12
    • 21644464868 scopus 로고    scopus 로고
    • Moisture buffering capacity of heavy timber structures directly exposed to an indoor climate: a numerical study
    • Hameury S. Moisture buffering capacity of heavy timber structures directly exposed to an indoor climate: a numerical study. Building and Environment 40 10 (2005) 1400-1412
    • (2005) Building and Environment , vol.40 , Issue.10 , pp. 1400-1412
    • Hameury, S.1
  • 14
    • 8744279608 scopus 로고    scopus 로고
    • Moisture performance of buildings envelopes with no plastic vapour retarders in cold climates
    • Simonson C.J., and Tuomo O. Moisture performance of buildings envelopes with no plastic vapour retarders in cold climates. Proceedings of Healthy Buildings 2000, vol. 3 (2000)
    • (2000) Proceedings of Healthy Buildings 2000, vol. 3
    • Simonson, C.J.1    Tuomo, O.2
  • 17
    • 1542531366 scopus 로고    scopus 로고
    • Contribution of indoor exposed massive wood to a good indoor climate: in situ measurement campaign
    • Hameury S., and Lundstrom T. Contribution of indoor exposed massive wood to a good indoor climate: in situ measurement campaign. Energy and Buildings 36 (2004) 281-292
    • (2004) Energy and Buildings , vol.36 , pp. 281-292
    • Hameury, S.1    Lundstrom, T.2
  • 19
    • 8744222026 scopus 로고    scopus 로고
    • Mass transfer between indoor air and a porous building envelope: Part II-Validation and numerical studies
    • Salonvaara M.H., and Simonson C.J. Mass transfer between indoor air and a porous building envelope: Part II-Validation and numerical studies. Proceedings of Healthy Buildings 2000, vol. 3 (2000)
    • (2000) Proceedings of Healthy Buildings 2000, vol. 3
    • Salonvaara, M.H.1    Simonson, C.J.2
  • 20
    • 49149126528 scopus 로고    scopus 로고
    • Passive climate control in Spanish office buildings for long periods of time
    • Orosa J.A., and Baaliña A. Passive climate control in Spanish office buildings for long periods of time. Building and Environment 43 12 (2008) 2005-2012
    • (2008) Building and Environment , vol.43 , Issue.12 , pp. 2005-2012
    • Orosa, J.A.1    Baaliña, A.2
  • 21
    • 56349096766 scopus 로고    scopus 로고
    • Improving PAQ and comfort conditions in Spanish office buildings with passive climate control
    • Orosa J.A., and Baaliña A. Improving PAQ and comfort conditions in Spanish office buildings with passive climate control. Building and Environment 44 3 (2009) 502-508
    • (2009) Building and Environment , vol.44 , Issue.3 , pp. 502-508
    • Orosa, J.A.1    Baaliña, A.2
  • 22
    • 67349160477 scopus 로고    scopus 로고
    • Energy saving with passive climate control methods in Spanish office buildings
    • Orosa J.A., and Oliveira A.C. Energy saving with passive climate control methods in Spanish office buildings. Energy and Buildings 41 8 (2009) 823-828
    • (2009) Energy and Buildings , vol.41 , Issue.8 , pp. 823-828
    • Orosa, J.A.1    Oliveira, A.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.