Volumn 7, Issue 1, 2010, Pages 27-34

Understanding the C-Pulse device and its potential to treat heart failure

Author keywords

Assist devices; Counterpulsation pump; Heart failure

Indexed keywords

AORTA BALLOON; BLEEDING; BLOOD FLOW VELOCITY; C PULSE DEVICE; CENTRAL VENOUS PRESSURE; CLINICAL EFFECTIVENESS; CLINICAL TRIAL; CONGESTIVE HEART FAILURE; CORONARY ARTERY BLOOD FLOW; COUNTERPULSATION; DEVICE INFECTION; DIASTOLIC BLOOD PRESSURE; EQUIPMENT DESIGN; HEART ABSCESS; HEART AFTERLOAD; HEART ASSIST DEVICE; HEART FAILURE; HEART OUTPUT; HEART RATE; HUMAN; IMPLANT; INTERMETHOD COMPARISON; LUNG ARTERY PRESSURE; MITRAL VALVE REGURGITATION; MULTIPLE ORGAN FAILURE; NEUROLOGICAL COMPLICATION; NONHUMAN; OFF PUMP CORONARY SURGERY; PATIENT SAFETY; POSTOPERATIVE COMPLICATION; QUALITY OF LIFE; REVIEW; SURGICAL APPROACH; SYSTOLIC BLOOD PRESSURE; TREATMENT CONTRAINDICATION;

EID: 77949264842     PISSN: 15469530     EISSN: 15469549     Source Type: Journal    
DOI: 10.1007/s11897-010-0007-7     Document Type: Review
Times cited : (21)

References (13)
  • 2
    • 0030019455 scopus 로고    scopus 로고
    • Implantable LVAD infections: Implications for permanent use of the device
    • discussion 372-353
    • McCarthy PM, Schmitt SK, Vargo RL, et al.: Implantable LVAD infections: implications for permanent use of the device. Ann Thorac Surg 1996, 61:359-365; discussion 372-353.
    • (1996) Ann Thorac Surg , vol.61 , pp. 359-365
    • McCarthy, P.M.1    Schmitt, S.K.2    Vargo, R.L.3
  • 3
    • 70349191771 scopus 로고    scopus 로고
    • Incidence and patterns of adverse event onset during the first 60 days after ventricular assist device implantation
    • 10.1016/j.athoracsur.2009.06.028 19766801
    • EA Genovese MA Dew JJ Teuteberg, et al. 2009 Incidence and patterns of adverse event onset during the first 60 days after ventricular assist device implantation Ann Thorac Surg 88 1162 1170 10.1016/j.athoracsur.2009.06.028 19766801
    • (2009) Ann Thorac Surg , vol.88 , pp. 1162-1170
    • Genovese, E.A.1    Dew, M.A.2    Teuteberg, J.J.3
  • 6
    • 72049129292 scopus 로고    scopus 로고
    • Temporary mechanical circulatory support
    • edn 3. Edited by Cohn LH. New York, NY: McGraw-Hill This review paper discusses the history, physiology, indications, and complications of intra-aortic balloon counterpulsation devices in class II-IV congestive heart failure patients
    • • McGee EC Jr, McCarthy PM, Moazami N: Temporary Mechanical Circulatory Support. In Cardiac Surgery in the Adult, edn 3. Edited by Cohn LH. New York, NY: McGraw-Hill; 2008:507-534. This review paper discusses the history, physiology, indications, and complications of intra-aortic balloon counterpulsation devices in class II-IV congestive heart failure patients.
    • (2008) Cardiac Surgery in the Adult , pp. 507-534
    • McGee Jr, E.C.1    McCarthy, P.M.2    Moazami, N.3
  • 7
    • 0014406108 scopus 로고
    • Initial clinical experience with intraaortic balloon pumping in cardiogenic shock
    • 10.1001/jama.203.2.113 1:STN:280:DyaF1c%2Fptlertw%3D%3D 5694059
    • A Kantrowitz S Tjonneland PS Freed, et al. 1968 Initial clinical experience with intraaortic balloon pumping in cardiogenic shock JAMA 203 113 118 10.1001/jama.203.2.113 1:STN:280:DyaF1c%2Fptlertw%3D%3D 5694059
    • (1968) JAMA , vol.203 , pp. 113-118
    • Kantrowitz, A.1    Tjonneland, S.2    Freed, P.S.3
  • 8
    • 0025151764 scopus 로고
    • Origins of intraaortic balloon pumping
    • 1:STN:280:DyaK3M%2FisVeqtQ%3D%3D 2222066
    • A Kantrowitz 1990 Origins of intraaortic balloon pumping Ann Thorac Surg 50 672 674 1:STN:280:DyaK3M%2FisVeqtQ%3D%3D 2222066
    • (1990) Ann Thorac Surg , vol.50 , pp. 672-674
    • Kantrowitz, A.1
  • 9
    • 43849099061 scopus 로고    scopus 로고
    • Extra-aortic implantable counterpulsation pump in chronic heart failure
    • This article offers the first case report using the C-Pulse device in a patient with advanced heart failure. The device implantation led to a dramatic improvement of the patient's ventricular function and quality of life, but resulted in a significant device-related infection
    • •• Mitnovetski S, Almeida AA, Barr A, et al.: Extra-aortic implantable counterpulsation pump in chronic heart failure. Ann Thorac Surg 2008, 85:2122-2125. This article offers the first case report using the C-Pulse device in a patient with advanced heart failure. The device implantation led to a dramatic improvement of the patient's ventricular function and quality of life, but resulted in a significant device-related infection.
    • (2008) Ann Thorac Surg , vol.85 , pp. 2122-2125
    • Mitnovetski, S.1    Almeida, A.A.2    Barr, A.3
  • 10
    • 24644517013 scopus 로고    scopus 로고
    • Extra-aortic balloon counterpulsation: An intraoperative feasibility study
    • 16159827
    • ME Legget WS Peters FP Milsom, et al. 2005 Extra-aortic balloon counterpulsation: an intraoperative feasibility study Circulation 112 I26 I31 16159827
    • (2005) Circulation , vol.112
    • Legget, M.E.1    Peters, W.S.2    Milsom, F.P.3
  • 11
    • 24644443525 scopus 로고    scopus 로고
    • Extra-ascending aortic versus intra-descending aortic balloon counterpulsation - Effect on coronary artery blood flow
    • DOI 10.1016/j.hlc.2005.03.018
    • AN Davies WS Peters T Su, et al. 2005 Extra-ascending aortic versus intra-descending aortic balloon counterpulsation-effect on coronary artery blood flow Heart Lung Circ 14 178 186 10.1016/j.hlc.2005.03.018 16352274 (Pubitemid 41419290)
    • (2005) Heart Lung and Circulation , vol.14 , Issue.3 , pp. 178-186
    • Davies, A.N.1    Peters, W.S.2    Su, T.3    Sullivan, C.E.4    Perkidides, T.5    Milsom, F.P.6    White, G.7
  • 13
    • 0029930885 scopus 로고    scopus 로고
    • Beat-to-beat augmentation of left ventricular function by intraaortic counterpulsation
    • DOI 10.1097/00000542-199603000-00009
    • AT Cheung JS Savino SJ Weiss 1996 Beat-to-beat augmentation of left ventricular function by intraaortic counterpulsation Anesthesiology 84 545 554 10.1097/00000542-199603000-00009 1:STN:280:DyaK283lvVeksw%3D%3D 8659782 (Pubitemid 26092527)
    • (1996) Anesthesiology , vol.84 , Issue.3 , pp. 545-554
    • Cheung, A.T.1    Savino, J.S.2    Weiss, S.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.