메뉴 건너뛰기




Volumn 55, Issue 10, 2010, Pages 3477-3485

A novel potentiometric sensor for promethazine based on a molecularly imprinted polymer (MIP): The role of MIP structure on the sensor performance

Author keywords

MIP structure; Molecularly imprinted polymer; Potentiometric sensor; Promethazine; PVC membrane

Indexed keywords

BIOLOGICAL FLUIDS; CONCENTRATION RANGES; ETHYLENE GLYCOL DIMETHACRYLATE; LOW DETECTION LIMIT; MEMBRANE ELECTRODES; METHACRYLIC ACIDS; MIP STRUCTURE; MOLECULARLY IMPRINTED POLYMER; NERNSTIAN RESPONSE; PROMETHAZINE; PVC MEMBRANE; RESPONSE TIME; SENSOR PERFORMANCE; VINYLBENZENE;

EID: 77949262300     PISSN: 00134686     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.electacta.2010.02.010     Document Type: Article
Times cited : (72)

References (37)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.